Entry  Sun Oct 9 20:57:54 2022, Nikolay Sosnin, Detectors in-beam, no target 12x
After long beam-off, changed detector mount by moving it 2 cm forward into the beam, after removing LiF 3.
Entry  Sat Oct 8 11:57:36 2022, Nikolay Sosnin, Change of Detector-Target Separation 17x
Increased detector-target (LiF 3) separation by 1.5 cm. Had to replace the support strut under the detectors due to the previous one being fuly retracted
even for minimal target-detector separation. This change may affect detector rotation relative to the target.
Entry  Sat Oct 8 11:56:49 2022, Nikolay Sosnin, Silicon Strips of Concern 
DEED 6 and 9 no signal throughout the campaign.

EFED 27 high oscillations in baseline throughout the campaign.
Entry  Fri Oct 7 20:04:30 2022, Nikolay Sosnin, Change of Pulser Setting 
The pulser has been switched from triggering from beam trigger to running at a 10 Hz rate, and will now appear in random places in signal traces. Planned
to run overnight measuring LiF3, switch to empty + detector in beam in the morning.
Entry  Fri Oct 7 17:17:08 2022, Nikolay Sosnin, Change of Pulser Delay 
Still using pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 11 microsecond delay from gamma flash to pulser. 20 mV
pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Changed pulser setting
to run with 11 microsecond delay for approx. 2 hour, then change to an overnight run with pulser running NOT triggered from beam.
Entry  Thu Oct 6 14:58:29 2022, Nikolay Sosnin, Change of Pulser Delay 
Still using pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20 mV
pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Changed pulser setting
to run with 5 microsecond delay for approx. 1 hour, then change to 10 microsecond delay.
Entry  Thu Oct 6 11:45:39 2022, Nikolay Sosnin, Assembly Setup Days 1 and 2 25x
Photographs of assembly up to the first pulser test with LiF3.
Entry  Thu Oct 6 11:07:47 2022, Nikolay Sosnin, Change of sample/Addition of pulser 
Changed from LiF 4 to LiF 3 after running with LiF 4 overnight (run title on n_TOF DAQ was not updated to refelect the change, and still says LiF 4,
but the material setting of the run states correctly that hte run is with LiF 3).

Added pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20
Entry  Thu Oct 6 09:34:30 2022, Claudia, Test setup Photos and cabling 20221005_174742.jpg20221005_174759.jpg20221005_184752.jpg20221005_184801.jpg20221005_174742.jpg
Setup 5.10.22

dE 20 um (ID 2837-33) and 494 um double sided (ID 1194-9)

46 channels (2 connectors missing)
Entry  Thu Oct 6 09:28:33 2022, Claudia, Items to be replaced for next run 20221005_122654.pdf
Missing/broken items identified

- long rails for fixing chamber on support

- vacuum valve (ours is broken)
Entry  Thu May 26 09:20:32 2022, Nick / Claudia, Inventory of Items at n_TOF for (n,cp) experiments rn_image_picker_lib_temp_e85b2099-7b73-4246-843d-6351800c2709.jpgrn_image_picker_lib_temp_3ff5f819-1e0c-4278-bbbc-01038a0a0c94.jpg
Detectors currently in the boxes:

2x MSL type W1(SS)-50, 2902-4 (53um), 2940-6 (55um)

1x MSL type W1(SS)-20 2837-33 (20um)
Entry  Fri Sep 9 10:01:18 2016, Sarah, Leakage currents 09.09.16 
EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA
Entry  Fri Sep 2 12:03:40 2016, Sarah, SPD card changed 
14 bit card replaced for DEED 9-12, to prevent issue with pulser arriving before gamma flash.
Entry  Fri Sep 2 12:01:57 2016, Sarah, Leakage currents 02.09.16 
E 0.03
dE 0.05
PHDI 0.12
Entry  Tue Aug 23 15:34:38 2016, Claudia, Leakage currents 23.08.16 
 E = 0.03uA
dE = 0.04uA
PHDI = 0.09uA
Entry  Wed Aug 17 15:10:05 2016, Sarah, Leakage currents 12.08.16 
 E = 0.03uA
dE = 0.04uA
PHDI = 0.06uA
Entry  Thu Aug 11 08:19:37 2016, Sarah, Leakage currents 10.8.16 
 At lunchtime (12.45)
E = 0.03 uA
dE  = 0.04 uA
Entry  Tue Aug 9 15:57:52 2016, Sarah, Leakage currents 09.08.16 
 Morning - 9am
E= 0.03uA
dE= 0.04uA
Entry  Mon Aug 8 11:02:13 2016, Sarah, Leakage currents 08.08.16 
 E 0.03 uA
dE 0.04 uA
PHDI 0.05 uA
Entry  Wed Aug 3 14:48:09 2016, Sarah, Leakage currents 02.08 - 03.08 
 02.08:
dE = 0.03 uA
E = 0.03 uA