AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  BRIKEN, Page 11 of 21  ELOG logo
Entry  Wed Mar 29 18:16:58 2017, RCF, 40Mg Run 002 201703300234-SyncScreenshot.png

Date: 30/03/2017
Entry  Wed Mar 29 17:15:21 2017, JLT, New Config file 
New configuration file:
170330_Conf_BrikenFull.xlsx
Entry  Wed Mar 29 15:16:17 2017, Many, 40Mg Run 001 
Date: 29/03/2017

Start: 23:13
Entry  Wed Mar 29 14:14:58 2017, Many, 40Mg RUN 000 
Date: 29/03/2017

Start: 22:13
Entry  Wed Mar 29 13:31:37 2017, J Agramunt, R. Caballero, T. Davinson, C. Griffin, O. Hall, D. Kahl, G. Kiss, J. Liu, S. Nishimura, V. Phong, JL Tain, Start of parasitic 170329_Conf_BrikenFull.xlsx
Start of parasitic Ca beam
(main experiment "New isotope search", Ahn et al.)
Entry  Wed Mar 29 11:02:40 2017, PV, Liu, JA, JLT, F11 plastic 
New calibration of F11 plastic

We decided to have both a low gain and a high gain 
Entry  Wed Mar 29 07:34:16 2017, J. Agramunt, BrikenTools repository installed at d05 
The last version of Briken tools repository has ben installed at d05, this repository includes the Merger and the BrikenOffline codes, as well as a CommonTools
folder to share scripts and code.

For update versions, just type in the desired directory "svn update".
Entry  Wed Mar 29 03:02:02 2017, J. Agramunt, Synchronization test procedure (update)  
To Launch the processes:

Open 4 terminals:
Entry  Tue Mar 28 17:02:19 2017, DK, Applying Biases 
Today, Gabor and I discussed with Nathan from ORNL about the biasing system used for Ge, 3He, Plastic, and others.  Phong is also a bit familiar with the
system (edit also 
Shintaro 
Entry  Tue Mar 28 09:10:09 2017, Many, 152Eu 170328_1707_152Eu_CloverCal.root170328_1707_CloverCalibration.ods
152Eu source inside BRIKEN for CLOVER calibration.
Also calibration of Si-dE with 60Co source
and AIDA_PL calibration  with 60Co source.
Entry  Tue Mar 28 06:56:15 2017, PV, Liu, JA, JLT, F11 Plastic 170328_1507_F11_PL_RandL.pdf170328_1838_F11PLCal.pdfNewF11Plastic.jpg
Calibration of new F11 plastic
(see photo)
Entry  Mon Mar 27 11:53:15 2017, PV,Liu, Turn on dE detector 1_top_60co.png2_top_noiselvl.png3_bottom_60co.png4_bottom_noiselvl.png
We applied a bias voltage of 100 V to the dE detector

Current read = 0.660 uA

compare with https://elog.ph.ed.ac.uk/BRIKEN/190.  it is slighly lower.
Entry  Mon Mar 27 09:32:55 2017, JLT JA CG OH DK TD RC VP GK LJ SN, 252Cf 170327_1800_252Cf.pdf170327_1800_252Cf.root170327_1800_252Cf_Cal.ods
252Cf at the center for BRIKEN calibration

Entry  Mon Mar 27 03:50:13 2017, JLT JA CG OH DK TD RC VP SN, Background 170327_1640_Background.pdf
Background measurement while they play with the beam.

Start: 11:40
Entry  Sat Mar 25 13:42:23 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, R. Caballero, Background 170325_2224_Background.pdf
BRIKEN system powered and DACQ started after movement.
All looks fine.
Entry  Sat Mar 25 13:33:12 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, R. Caballero, BRIKEN+AIDA relocated NewLocation1.jpgNewLocation2.jpg
We moved AIDA+BRIKEN by 107cm upstream.
See attached photos.
Entry  Fri Mar 24 03:28:39 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, Background 170324_1040_BackgroundOvernight.pdf
Background measurement overnight

Start: 19:45
Entry  Thu Mar 23 10:03:51 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, 252Cf 170323_1902_1938_252Cf.pdf
252Cf source at the center for calibration

23/03/2017
Entry  Thu Mar 23 09:30:58 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, Power-up and 1st spectrum 170323_1841Background.pdf
Crates powered up.
DACQ started.
New directory: /data/1703Preparation/
Entry  Thu Mar 23 09:04:38 2017, JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura, Remove EURICA rails Donwstream-EURICA-Rail.jpgUpstream-EURICA-Rail.jpgGeneralView.jpg
We remove partially the floor rails of EURICA 
to proof that it is possible to move BRIKEN + AIDA.
ELOG V3.1.4-unknown