AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  BRIKEN, Page 20 of 21  ELOG logo
ID Date Author Subjectdown
  363   Thu Oct 18 00:31:55 2018 AT & AT252Cf long measure, z=0cm, threshold 5% lower
18/10/18 START: 08:31
18/10/18 STOP: 10:50

** Use of other configuration file:
181016_Conf_BrikenFull_2153_test_thr.xlsx

ROOT file: 181018_1050_252Cf_z0cm_lowThr.root
DLT: 
191017_0831_252Cf_z0cm_lowThr_014.dlt
191017_0831_252Cf_z0cm_lowThr_015.dlt
191017_0831_252Cf_z0cm_lowThr_016.dlt

Comment: 
- 252Cf source placed at the center using cardboard piece, z=0cm, orientation of the source with its axis parallel to the beam axis, i.e. axis of the source upstream to the beam. 
- 3He counters with a threshold 5% lower compared to previous measurement.
- Clovers inside the moderator, surface position 11.6/2 cm from the each one. 
- AIDA not inside the moderator.
- Without in beam PE shielding. 
  365   Thu Oct 18 08:21:18 2018 AT2, JLT, SN252Cf long measure, z=0cm, no clovers
18/10/18 START: 17:22
18/10/18 STOP: 20:09

** Use of other configuration file: 
181016_Conf_BrikenFull_2153_test_thr.xlsx

ROOT file: 181018_1722_252Cf_z0cm_2010.root
DLT: 
181018_1722_252Cf_z0cm_021.dlt
181018_1722_252Cf_z0cm_022.dlt
181018_1722_252Cf_z0cm_023.dlt


Comment: 
- 252Cf source placed at the center using cardboard piece, z=0cm, source axis perpendicular to
the beam axis.
- Clovers WITHOUT the moderator. 
- AIDA not inside the moderator.
- Without In beam PE shielding.
  361   Wed Oct 17 09:20:20 2018 AT & AT252Cf long measure
18/10/17 START: 18:16
18/10/17 STOP: 22:00

ROOT file: 181017_1816_252Cf_z0cm_2200.root
DLT: 
181017_1816_252Cf_z0cm_000.dlt
181017_1816_252Cf_z0cm_001.dlt
181017_1816_252Cf_z0cm_002.dlt
181017_1816_252Cf_z0cm_003.dlt

Comment: 
- 252Cf source placed at the center using cardboard piece, z=0cm, orientation of the source similar to past year
measurements, i.e. axis of the source perpendicular to the beam axis.
- Clovers inside the moderator, surface position 11.6/2 cm from the each one. 
- AIDA not inside the moderator.
- Without in beam PE shielding.  
  338   Sat Oct 21 17:14:55 2017 JA, ATD, JLT252Cf efficiency calibration
Measurement of BRIKEN neutron counter efficiency
252Cf source in the (approximately) center
Wasabi and D4 clover inserted. G7 on the floor.
YSO on the box with light pulser.

The source was plug in a Styrofoam piece at the right height
so that it could be centered longitudinally with the D4 Clover
and transversely with the Wasabi nose.
Possible position difference with previous efficiency
measurements using the cardboard source holder
should not impact the efficiency obtained.


Start: 00:41
Stop: 01:08
Run number: 36
List mode: 171022_0041_252Cf_036.dlt
Root file:  171022_0041_0108_252Cf.root
 
Attachment 1: Screenshot_from_2017-10-22_01-21-51.png
Screenshot_from_2017-10-22_01-21-51.png
  48   Wed Jul 20 11:40:00 2016 J.L. Tain, J. Agramunt, R. Baeturia, A. Tarifeņo, A. Tolosa, ...252Cf
First measurement with full 140 tube version 
of the BRIKEN neutron detector

Directory: /data/160716Test01/
Configuration: 160718Conf_BrikenFull.xlsx
File: 160718_FullBrikenFirstData_252Cf_002.dlt
Online: 160718_FullBrikenFirstData_252Cf.root

All tubes and channels working!

Sample of screenshots included.
Attachment 1: RIKEN-252Cf-V1A1.png
RIKEN-252Cf-V1A1.png
Attachment 2: UPC-252Cf-V1A3.png
UPC-252Cf-V1A3.png
Attachment 3: ORNL1-252Cf-V1A5.png
ORNL1-252Cf-V1A5.png
Attachment 4: ORNL2-252Cf-V1A6.png
ORNL2-252Cf-V1A6.png
  50   Wed Jul 20 12:00:15 2016 J.L. Tain, J. Agramunt, A. Tarifeņo, A. Tolosa, ...252Cf
Measurement with the source at the center

Listmode: 160719_BRIKEN_252Cf_009.dlt
Online: 160719_BRIKEN_252Cf.root

BRIKEN: 1.03697E7
Pulser: 5985

Rate: 17326 n/s
  51   Wed Jul 20 16:07:58 2016 A.Tarifeņo, J.L. Tain, J. Agramunt, A. Tolosa, ...252Cf
19/Jul/2016
Scanning of the efficiency as a function of longitudinal position

File:160719_BRIKEN_252Cf_XXmm_*.dlt
Online:160719_BRIKEN_252Cf_XXmm.root
Run: 011-025
Distances: -275,-175,-125,-75,-50.-25,+25,+50,+75,+125,+175,+225,+275,+375mm
  54   Wed Jul 20 16:50:12 2016 J.L. Tain, J. Agramunt, A. Tarifeņo, A. Tolosa, S. Go...252Cf
Measurement of the 252Cf source at the central position

Efficiency and neutron-gamma correlations

Listmode: 160719_2233_252Cf_XX.dlt, Run: 029-030
Online: 160719_2233_252Cf_029_030.root
  65   Thu Oct 6 14:50:30 2016 JL Tain, A Tolosa, A Tarifeno,...252Cf
First measurement with 252Cf source to check the calibration.
AIDA was in place so the source was at the right height
but displaced about 10cm from the center.

We use the last configuation file used in July: 
160718Conf_BrikenFull_cal5.xlsx

tmeas=25min
file: 161006_2235_252Cf.root

The noise is rather small.
The calibration of July is nearly OK!
Attachment 1: 252Cf-1st.pdf
252Cf-1st.pdf
Attachment 2: 161006_2235_252Cf.pdf
161006_2235_252Cf.pdf
  84   Thu Oct 13 23:41:25 2016 JL Tain et al252Cf
New BRIKEN energy calibration


We check the 3He tubes energy calibration with 252Cf source
We Found that only one tube He006 was slightly shifted and correct it.

Check measurement:
File: 161014_0113_252Cf.root

See figure
Attachment 1: 252Cf-161014.pdf
252Cf-161014.pdf
  102   Thu Nov 3 04:46:24 2016 Alvaro Tolosa252Cf
Check of BRIKEN calibration and thresholds

Source more or less at the center

Online File: 161103_1319_252Cf.root
Attachment 1: 161103_1319_252Cf.root
  155   Tue Nov 22 10:17:57 2016 ATS, PV, LIU252Cf
Measurement with 252Cf at Z=22.5cm from the moderator border, opposite side from AIDA.
Clovers and Veto detectors are turned off.
Beam is off.

Files: 
161122_1820_001.dlt
161122_1820_002.dlt
161122_1820_001.root
Obs: There is a problem in the online data for this run. DAQ for VME1 do not stored data. This problems seems to
be a crash on the DAQ. I restarted the system and run again the measurement. The display for voltages has lost
connection. The channels on VME1 have been checked, no problems is observed in the waveforms.

Again, this time without observing problems:
File:
161122_2208_003.dlt
161122_2208_003.root

BRIKEN spectrum is attached for this run. Counts in the pulser are 1.123e4
Attachment 1: 161122_2208_003_BRIKEN.svg
161122_2208_003_BRIKEN.svg
  158   Thu Nov 24 14:36:27 2016 AT252Cf
Check of calibrations and rates for neutron detectors with Conf File 161107Conf_BrikenFull.xlsx

Measurement 161122_2208_003.root has been used to check the calibrations and counting rates in the BRIKEN
detector. Condition of the measurement:
252Cf at 22.5cm from moderator, opposite sede from AIDA

RESULTS

Calibrations factors:
Calibrations of the neutron detectors are reasonable in the current conditions. A check detector by detector
(see attached file) shows that the full peak for most of the counters is around 764keV. Only 3 counters are
shifted more than 10keV:
He134	741.901
He135	750.312
He140	748.587	

The impact on the counting rates would not be serious.

Counting rates (n/pulser):
#########################################
Total neutron rate:	1516.28
#########################################
	BY RING:
#########################################
R1	359.057
R2	222.997
R3	386.299
R4	253.833
R5	143.434
R6	90.6357
R7	60.025

The total current counting rate is lower than rate obtained in Oct 12th (total 1550.91 n/pulser). The difference
is due mainly to a decrease in the counting rates for rings 1 to 4.
Attachment 1: CalibrationCheck_161122.xlsx
  197   Thu Mar 23 10:03:51 2017 JL Tain, J Agramunt, V. Phong, C. Griffin, O. Hall, S. Nishimura252Cf
252Cf source at the center for calibration

23/03/2017
Start: 19:02
Stop: 19:38

Root file: 170323_1902_1938_252Cf.root
Attachment 1: 170323_1902_1938_252Cf.pdf
170323_1902_1938_252Cf.pdf
  202   Mon Mar 27 09:32:55 2017 JLT JA CG OH DK TD RC VP GK LJ SN252Cf
252Cf at the center for BRIKEN calibration


Start: 17:31
Stop: 18:00

File: 170327_1800_252Cf.root

3He tube calibration done with script BrikenCal.cpp
Result stored in 170327_1800_252Cf_Cal.ods (attached)

After visual superposition of all spectra we decided
to change only the parameters of He003 and He133
in the new calibration file.
Attachment 1: 170327_1800_252Cf.pdf
170327_1800_252Cf.pdf
Attachment 2: 170327_1800_252Cf.root
Attachment 3: 170327_1800_252Cf_Cal.ods
  301   Thu May 25 13:42:45 2017 AT, PC,KR,JLT,AA252Cf
252Cf source in Z=0cm position. 

Start:21:41
Stop:21:52 


Files
170525_2141_252Cf_z0cm_006.dlt
170525_2141_2152_252Cf_z0cm.root

We realized that the time stamp was not reset.
  302   Thu May 25 13:56:00 2017 AT, JLT, AA252Cf
252Cf source in Z=0cm position. 

Start:21:57
Stop: 22:26


Files
170525_2157_252Cf_z0cm_008.dlt
170525_2157_2226_252Cf_z0cm.root

The time stamp was reset finally (at the third try !!!)

There is a file 170525_2154_252Cf_z0cm_007.dlt which was taken for a short time, until we noticed again that the
time stamp was not reset. 
  93   Tue Oct 18 09:36:07 2016 Alvaro Tolosa2016-Oct, Logbook
Paper logbook for October-2016
For correct visualization, 
please download it.
Attachment 1: 16Oct_logbook.pdf
16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf 16Oct_logbook.pdf
  94   Tue Oct 18 09:41:43 2016 Alvaro Tolosa2016 - July, Logbook
Paper logbook for July-2016
For correct visualization, 
please download it.
Attachment 1: 16Jul_logbook.pdf
16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf 16Jul_logbook.pdf
  324   Tue Jun 13 06:50:12 2017 Briken Colaboration152Eu calibration
After experiment 152Eu calibration



Working directory: /data/1706FinalCalibrations
Configuration file: 170604_Conf_BrikenFull_AfterCrisis.xlsx

DLT file name: 170613_1451_152Eu_000.dlt
Start: 14:51
Stop: 15:24
Online rootfile:152Eu_cal_z0_1451_1524_170613.root

COMMENTS:

1. Source centered in both BRIKEN and clovers (faced towards clover D4)
2. No AIDA in
3. D4 clover pulsers are at 253, 260, 265, and 271 keV
4. G7 clover pulsers are beyond 5 MeV. No pulser for crystal G7Green
Attachment 1: 170604_Conf_BrikenFull_AfterCrisis.xlsx
ELOG V3.1.4-unknown