AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME, Page 18 of 38  ELOG logo
Entry  Mon Feb 28 05:04:47 2022, JM, OF, Temperature cycle to 125K 2022-02-28_06-30-39-Exrate.png
06:01

Rutherford rate was decreased compared to previous values. Max rate ~ 50 counts for the peak, average ~20 counts. 

Temperature increased to 125 K
Entry  Fri May 30 21:49:08 2025, JM, NP, CB, Run 37 Screenshot_from_2025-05-31_00-56-32.pngScreenshot_from_2025-05-31_00-58-40.pngScreenshot_from_2025-05-31_06-16-50.png
22:49

Run 37 started.

D+ beam deuterium target. D+ beam energy is 2 MeV/u. (beam calc calculation is 1.9211 MeV/u)
Entry  Thu Feb 24 14:31:25 2022, JM, ML, CN, Beam Tuning Run 76 6x
15:30

1.5 MeV/u beam currently being tuned

Target is ON, setpoint = 135 K
Entry  Sat Jun 15 21:14:56 2024, JM, JS, LC, Run 76 Screenshot_from_2024-06-15_22-16-53.png
22:15

New run 76 - beam on target with definite target overlap [coasting]

Cooler voltage setpoint 247.1 V.
Entry  Fri Jun 14 13:45:21 2024, JM, JS, CB, TD, EH, Run 70 - beam on target 7x
14:45

New run 70 - beam on target with definite target overlap

Cooler voltage setpoint 247.3 V.
Entry  Thu Jun 13 00:50:33 2024, JM, JS, Run 64 - beam on target 
01:50

Right arm at 64.60 mm

Left arm IN at 36.54 mm
Entry  Sat Jun 15 13:30:18 2024, JM, JS, Run 75 Screenshot_from_2024-06-15_15-53-57.pngScreenshot_from_2024-06-15_15-54-30.pngScreenshot_from_2024-06-15_15-54-55.png
14:30

New run 75 - beam on target with definite target overlap [coasting]

Cooler voltage setpoint 247.2 V.
Entry  Mon Feb 19 08:45:22 2024, JM, JG, SHB, EM, EH, Run 44 - cooled beam on target 35x
09:43

Run 44 started cooled beam on target

Detectors IN (left arm pot =36.5 mm, right arm pot = 70.49 mm). Stationary. Same as previous runs
Entry  Thu Feb 15 10:39:50 2024, JM, JG, ML, AG, CB, Run29 - beam optimisation 
11:27

Run 29 started. Beam energy is 1.3435 MeV/u with a cooler voltage of 751.3 V.

We observe significantly greater count rate for top right detector (DSSD#1) now that the beam energy has been lowered. ADC over range? Beam target
Entry  Mon Jun 2 09:30:38 2025, JM, EW, ST, Run 41 6x
Run 41 started.

D+ beam deuterium target. D+ beam energy is 0.75 MeV/u. (beam calc calculation is 0.7619 MeV/u). See previous entry for beamcalc.

Beam calc - Attachment 1
Entry  Sun Jun 2 22:46:47 2024, JM, EM, NP, Run24 Screenshot_from_2024-06-02_23-53-00.pngScreenshot_from_2024-06-02_23-53-47.pngScreenshot_from_2024-06-02_23-56-22.png
23:47

Run 24 started - Beam on target

Beam energy is 1.5 MeV.
Entry  Sat Jun 1 21:56:17 2024, JM, EM, EM, TY, CB, AG, Run 20 18x
22:56

Run 20 started - beam on target

Beam energy is 1.5 MeV. Horizontal beam position = 7.0 mm, vertical beam position = 0.0 mm.
Entry  Sat Jun 7 10:06:27 2025, JM, EM, CB, DB, AY, PC, CB, Run 54 50x
11:10

We have started a new run at the same energy as R53 (250 keV/u) due to an issue with the DAQ pc

Server and DAQ restarted
Entry  Sun Jun 1 07:46:34 2025, JM, EM, CB, Run 39 7x
08:45

Run 39 started.

D+ beam deuterium target. D+ beam energy is 1.0 MeV/u. (beam calc calculation is 1.0151 MeV/u)
Entry  Mon Feb 28 22:34:51 2022, JM, EM, Current status 2022-02-28_23-40-14-xyTotal.png2022-02-28_23-39-56-Exrate.png2022-02-28_23-39-26-goodEvents.png2022-02-28_23-38-58-correlation8.png2022-02-28_23-38-31-ADCitems.png
23:35

Temperature setpoint = 116 K

Detector position IN, potentiometer reads 34.89 mm
Entry  Mon Feb 28 23:54:02 2022, JM, EM, Current Status, Temperature cycle 2022-03-01_00-57-44-Exrate.png2022-03-01_00-58-41-ExTotal.png2022-03-01_00-58-14-EyTotal.png
00:51

Temperature setpoint = 116 K

Detector position IN potentionmeter = 34.89mm
Entry  Tue Mar 1 02:15:29 2022, JM, EM, Current status 6x
03:15

The nozzle motor control at the target crashed, but operation has been restored.

Temperature setpoint = 116 K
Entry  Tue Mar 1 03:19:50 2022, JM, EM, Temperature Cycle 
04:20

Did another temperature cycle (118 K -> 125 K -> 95 K -> 116 K) trying to improve the pressures at the target and the detector count
rate.
Entry  Tue Mar 1 03:34:28 2022, JM, EM, Current status 7x
Temperature setpoint = 116 k

Detector IN potentiometer = 34.89 mm

Rutherford rate is reduced from previous entries. Avergae peak height appears to be ~50 counts. Fluctuations in peak height and E4 pressure are
Entry  Tue Mar 1 04:07:31 2022, JM, EM, Temperature cycle 
Have been unable to achieve decent target density with temperature cycling so far. Will attempt to go up to 300 k and back down to around 115 k which
proved successful in previous shifts.
ELOG V3.1.3-7933898