Entry  Wed Feb 23 20:52:56 2022, CN, TD, System wide checks 11x

Attachments 1-5 aida01-aida05 options
Entry  Mon Jun 3 15:10:12 2024, CN, EM, CB, Run28 Screenshot_from_2024-06-03_16-12-44.pngScreenshot_from_2024-06-03_16-13-11.pngScreenshot_from_2024-06-03_16-14-11.pngScreenshot_from_2024-06-03_16-16-37.png
16:10

We start a new run after doing some test with the motor. Injection time is now a 6s, moving of the motors is working fine.

Merger OK, Tape server OK
Entry  Mon Jun 3 15:17:41 2024, CN, EM, CB, Run29  Screenshot_from_2024-06-03_18-04-47.pngScreenshot_from_2024-06-03_18-05-11.pngScreenshot_from_2024-06-03_18-06-09.pngScreenshot_from_2024-06-03_18-06-40.pngScreenshot_from_2024-06-03_20-35-00.png
16:15

In the previous run while working on the target it was discovered that the valve was closed! Probaly this happened around 10 am, we are not sure.

The gas target inlet valve is open again, working on the target.
Entry  Mon Jun 3 21:37:20 2024, CN, EM, CB, Run30 Screenshot_from_2024-06-03_23-15-37.pngScreenshot_from_2024-06-03_23-16-18.pngScreenshot_from_2024-06-03_23-17-16.png
Beam energy = 3 MeV

Horizontal beam position = 7.0 mm, vertical beam position = 0.0 mm.

Beam intensity at inj ~ 2.5e7
Entry  Mon Feb 5 19:43:52 2024, CB, TD, ML, BuTIS reference for VETAR2 20240205_173029.jpg20240205_172957.jpgScreenshot_from_2024-02-05_16-43-18.png

16.40 CB/ML install fibre optic cable from patch panel beneath dipole downstream of YR09/CARME chamber to VETAR2 front panel fibre connector - see attachments
1 & 2.
Entry  Thu Feb 24 04:17:35 2022, CB, TD (remotely), MIDAS DAQ no longer working Bad_Time_2022-02-24_04-34-12.pngBadTime_WRTime_2022-02-24_04-34-53.png
DAQ server crashed around 24:00

Rebooted server but could not could not rescue remotely - could not contact raspberry pi in control of FEE bias.

Entered cave, rebooted raspberry pi. Would not accept remote connections.
Entry  Tue Oct 5 11:44:11 2021, CB, TD , SAES manuals & cable drawings 8x
NEG power
SIP power
UHV1400 operating instructions
Entry  Mon Feb 28 14:42:48 2022, CB, TD, Cryostat set to 115K 

Cryostat set to 115K
Entry  Mon Feb 28 14:47:52 2022, CB, TD, Monday 28 February 15:00-23:00 17x

15.51 1.8.W spectra 20ms, 2ms, 200us, 20us FSR - attachments 1-8
Entry  Sat Feb 3 15:05:10 2024, CB, TD, [How To] Restart Anydesk 
1. Check Proxy server is correct

localhost : 8080

incoming connections 7070
Entry  Mon Feb 5 20:15:31 2024, CB, TD, Detector move in/out signals 20240205_174307.jpg
17.43 setup signals from detector movement controller.

See attachment 1
Entry  Wed Mar 2 22:29:48 2022, CB, SD, Last shift with beam 9x
22:30 Shift handed over. DAQ OK. Target OK. Beam OK.

 

00:22 Temperatures OK
Entry  Tue Jun 11 04:36:17 2024, CB, RSS, JS, Run 60 - as 59, left servo in 11x
05:36

Run started.

Conditions as before, except left servo now really in.
Entry  Wed Jun 19 12:11:22 2024, CB, RSS, CARME status 
DSSD off

FEEs off

Motors out, pin inserted, compressed air closed, power removed from motors box.
Entry  Thu May 30 09:30:33 2024, CB, PW, YL, TD, Run 10 13x
10:30

Merger OK, Tape server OK

ADC data item statistics looks as before. OK
Entry  Thu May 30 08:33:21 2024, CB, PW, YL, Run 8 & 9- detector motion tests 7x
09:34 - Moved to Run 9 in preparation of moving detectors. No target yet. Beam in the ring at 750 keV/A.

Temperatures OK (attach)

System wide checks OK except 16 fails clock and ADC calib
Entry  Wed Jun 11 08:37:48 2025, CB, PJW, Run 66 Screenshot_from_2025-06-11_10-21-30.pngScreenshot_from_2025-06-11_10-21-44.png
09:38

As Run 65, no changes, CRYRING operators attempting to improve beam intensity.

We should be able to keep running while they do, but there is a chance of some missed injections or other oddities.
Entry  Thu Feb 24 05:09:47 2022, CB, PE, EM, Inlet valve at target closed + problems with turbopump 
The turbo pump E1 is continuing to draw too much current and the rotation frequency has steadily decreased from 817 Hz at the beginning of the night
shift to 800 Hz now. The frequency recovered after the temperature was increased.

Both of the valves (inlet and dump) have been closed to improve the vacuum in the ring.
Entry  Wed Aug 30 09:33:13 2023, CB, OG, NEG cables repaired  20230830_102519.jpg20230830_102514.jpg
Repaired Neg wires for D2000 with Oemer's help.

Cable #2 is fine. 

In Cable #4, wires 1 and 2 are swapped but it's impossible this happened when the connector came apart. The pins are crimped and secured
Entry  Wed Jun 19 12:06:50 2024, CB, OF, SS, Run 98/99/100 - higher energy 
10:21 June 17

New energy: 1.125 MeV/u

Target in. Run 98 started.