602
Wed Apr 24 15:37:59 2024
PP
16:00-00:00 shift Wednesday 24 April
All seems OK.
Screenshots attached.
8x
603
Wed Apr 24 18:44:05 2024
PP
19:30 checks
All seems smooth.
Screenshots attached.
8x
652
Tue Jun 11 18:45:37 2024
PP
Mid-shift checks, 19:45
All looks good.
Sceenshots attached.
8x
656
Wed Jun 12 11:06:55 2024
PP
Mid-shift checks, 12:00
All seems normal.
Screenshots attached.
8x
517
Wed Jan 18 13:40:33 2023
PJCS TD
MACB settings with either Emulator or VITAR
When using the VETAR connected
to the HDMI port of the root MACB the settings
for all the MACB in the system 0x3.
157
Wed Mar 18 18:02:37 2020
PJCS
New Firmware loaded in all FEE64s
Loaded new frimware into all 12 FEE64s
in the system. IWR_Dec19_4.bin
Booted ok after power-cycle.
209
Wed Mar 31 12:46:10 2021
PJCS
HowTo : Calibrate the LMK3200 clock devices
Here is a document showing how and where
to calibrate the LMK3200 devices that lock
to the system clock and generate the clocks
210
Wed Mar 31 15:40:42 2021
PJCS
Check Options files function added
There is a new operation available in the
System Functions menu in the System Wide
Checks page. ( The page needs to be reset
211
Wed Mar 31 15:46:09 2021
PJCS
HowTo : Synchronize the ASIC clocks.
To Synchronize the FEE64 ASIC clocks to
rise at the same timestamp time use the System
function Synchronise the ASIC clocks
220
Wed Apr 14 12:14:47 2021
PJCS
Corrections and changes
14/4/21 @12:00 UK time
Corrected the failure of FADC re-calibration
All modules. The problem was a missing >
221
Wed Apr 14 15:14:55 2021
PJCS
Note Well
Please note that for the forseeable future
the system function in the menu on the System
Wide Checks browser page labelled as
300
Fri May 7 19:47:54 2021
PJCS
HowTo mitigate excessive temperature in an FEE64
After tests in the Daresbury T9 system.
Disabling the waveform ADCs in
an FEE64 which is running with the FPGA over
396
Wed Feb 16 10:32:52 2022
PJCS
AIDA software changes and some suggestions
The Pi console monitor program now outputs
a full date/time to file for each line of
report.
490
Wed Jun 22 10:09:12 2022
PJCS
INFO: FEE64 supply Voltages
Study of the FEE64 power supply distribution
has yielded the following :-
The most sensitive regulator, as
514
Wed Sep 14 19:07:07 2022
PJCS
INFO : Three Merger Statistics explained
There are three Merger statistics that
can be used to better understand how the
data flow through the Merger system is proceeding.
225
Fri Apr 16 00:47:36 2021
OH-ML
AIDA DAQ Reset
1:18 (CET) No rate in AIDA 07.
Oscar did a AIDA DAQ reset and
a quick wide check.
1
Thu Sep 6 15:11:17 2018
OH, TD
Tuesday 4 September - Thursday 6 September
Attachment 1 - FEE64 temperatures illustrating
(we assume) a faulty PSU temperature sensor
for aida07
19x
2
Thu Sep 6 15:25:19 2018
OH, TD
AIDA@DESPEC Setup Photos
3
Thu Sep 6 15:42:53 2018
OH, TD
FEE64 system console logs
Kernel panics during boot cab be observed
in files ttyUSB1 and ttyUSB5
5
Wed Sep 19 12:40:41 2018
OH, TD
Single DSSD Installation and Tests
On the 18th of September we installed DSSD
3208-14