AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nTOFCapture, Page 3 of 4  ELOG logo
Entry  Fri Aug 7 10:57:10 2020, Ruchi, Monday meeting slides: 03 Aug 2020_08_03.pdf
 
Entry  Mon Jul 27 17:40:41 2020, Nikolay Sosnin, Meeting Slides (Calibrations + WFs) Broadening_Round1.pptxWeighting_Gold.pptx
 
Entry  Fri Nov 3 15:06:51 2017, Claudia, Measurement Schedule updated measurementplan_new.pdf
 
Entry  Fri Jul 3 14:01:38 2020, Claudia, Link to Ruchi's list of runs + description 
 https://docs.google.com/spreadsheets/d/1W1T2rC10UtOtrAaT8-ZAKFvX70v2PwDk_4-goYL-brI/edit?usp=sharing
Entry  Thu Jun 29 09:21:13 2023, Annie, Info on Samples IMG_2242.JPGIMG_2248.JPGIMG_2247.JPGIMG_2246.JPG
Both Au samples (20mm and 22mm) are single mylar.

Both Si30 (22mm) and natSi (20mm) are double mylar.

Empty is single mylar ONLY
Entry  Fri Jun 7 15:58:24 2024, CLW, ISOFLEX Certificates for enriched Si samples Si30_isoflex.pdf231226-01_-_Shipping_Documents(1).pdf
Isoflex certificates for enriched silicon samples
Entry  Thu Jun 22 10:37:39 2023, Annie, Gold 22mm Sample Images IMG_2187.JPGIMG_2186.JPGIMG_2185.JPG
New 22mm sample compared to old 20mm sample used at the beginning of the campaign + picture of dummy target in the setup.
Entry  Thu Apr 4 09:50:36 2024, CLW, First Si analysis 2024 run 6x
Au and Si29 runs normalised by proton number show consistency (dedicated pulses, example detector 4). Plots for tof spectra zooming on one resonance
and histogram of counts in this resonance divided by protons with statistical errors.

Plots were produced with the macros attached.
Entry  Fri Jul 29 17:21:47 2022, Ragan, Enriched Si-30 IMG_2692.jpgIMG_2693.jpg
Attached are the pictures of enriched Si-30 metal pieces.
Entry  Fri Jul 28 12:19:10 2023, Michael Donnachie, EAR2 consistency checks, PKUP BCT SILI and normalised counts  10x
The EAR2 ratios of BCT/PKUP, BCT/SILI and PKUP/SILI plotted for each run for samples Si, Sinat, Au20, Au22 and Dummy. 

Also included is the normalised counts (counts/BCT) with 7 detectors on one plot (STED8 was ommited).  'counts' for Si
was integreated over the Si resonance, for Au it was integrated over the largest resonance. For Dummy and Sinat the counts were integrated over a
Entry  Mon Jul 31 12:00:02 2023, Nikolay Sosnin, EAR2 Silicon Samples EAR2_30Si.JPGEAR2_Sinat_Closeup.JPGGoodfellow_Sinat_Sample.JPGLaser_Alignment.JPG
 
Entry  Mon Aug 28 12:21:09 2023, Michael Donnachie, EAR2 STED Calibration Parameters 8x
Calibration parameters for each STED detector: With function f=p0+p1*x+p2*x*x





Detector

p0 Value 
p0 Error
p1 Value
p1 Error
p2 Value
p2 Error



STED
Entry  Mon Aug 28 14:07:23 2023, Michael Donnachie, EAR2 Experiment vs Simulated Amplitude Spectrums 28x
Attatched are the overlayed compton edges for the calibrated experimental and the GEANT4 simulations. Note p1 and p2 denotes the lower and higher energy
compton edges for Yttrium. 

The experimental and simulated histograms are shifted in quite a few of these plots suggesting the calibration was not fully successful.
Entry  Fri Jul 28 12:07:33 2023, Michael Donnachie, EAR2 C6D6 timeshift issues Au20_C6D6_both_det_timeshift.pdfAu22_C6D6_both_det_timeshift.pdfSi30_C6D6_bothdet_3runs.pdf
There seems to be issues with the EAR2 C6D6 T histograms. For Au the earlier run seems to be shifted for detector 2 compared to the rest. 

For Si plotted is 3 different runs 216123, 216128 and 216135 for both detectors. The histogram is messy but highlights that there
is a problem. The single Si resonace should be around 20 000ns and this is only the case for run216128. 
Entry  Tue Aug 29 10:32:35 2023, Michael Donnachie, EAR1 Parasitic vs Dedicated runs  6x
Below are the histograms of parasitic vs dedicated runs for EAR1. Also included are histograms with ambient background removed which closes the
gap between parasitic and dedicated histograms. This was preformed by scaling the ambient by counts by a multiplication of (dedicated or parasitic) bunch
number/ambient bunch number. There are no legends but the dedicated counts are in black and parasitic counts in red. Only included are C6D6 1 detectors
Entry  Wed Nov 15 13:40:50 2023, Claudia, Determination of neutron capture yield and related corrections evalFlux_prelim.rootnTOF-Ph2_fluence_2009-2011_6Dec2011.rootBIF_2011_norm.rootenergyandyield.c
Here are all the files needed for calculation of the yield. There is some information that still needs to be added to the energyandyield.c file, for
example the atomic mass of your target in amu, the neutron separation energy for the compound nucleus in MeV (this is needed due to using the Weighting
technique). Also, you need to add some lines  to read the tof histogram, which will then be converted in a neutron energy hisogram and then divided
Entry  Sat Mar 23 15:06:44 2024, Nick, Detector Setup - 28/29Si Campaign 2024 9x
Campaign started yesterday. C6D6s placed at 9 cm distance, angle 125 degrees w.r.t beamline.

Measured calibration sources: Cs137, Y88, AmBe, CmC. Measuring Si-nat over the weekend.

Detector          Voltage
Entry  Fri Nov 3 11:22:43 2017, Claudia, Detector Configuration fig1.jpgfig2.jpgfig3.jpg
Distance Sample to Detector: Det1: ~10.5 cm, Det2: 11 cm, Det3: 11 cm, Det4: 11 cm

 
Entry  Mon Aug 3 14:27:18 2020, Nikolay Sosnin, Dead-time and BG Subtraction Meeting Slides Subtracted_Spectra.pptxDeadtimes.pptx
My TTOFSort macro is located in

/afs/cern.ch/work/n/nsosnin/public/C6D6_Calibration/Calibration_Data/Calibrator.C 
Entry  Fri Dec 1 15:34:01 2023, AR, Corrected BG Subtraction plots for Zn and Au 6x
Updated plots for Zn and Au
ELOG V3.1.4-unknown