Entry  Mon Oct 3 16:03:33 2022, OH, CB, TTT14 Photos 
Photos of the new TTT14 DSSD delivered to GSI.
Photos of detectors are broken up by photos of SN on box
To big to put on elog. Have uploaded to /Disk/ds-sopa-group/np/GSI/CARME/TTT14_Photos.zip and will change permissions to 777
Entry  Sun Aug 14 06:50:58 2022, TD, JM, Sunday 14 August 10x

07.51 DAQ continues files 22Feb/R97
Entry  Sat Aug 13 10:23:59 2022, JM, TD, Noise tests pt3 and pulser walk 15x
Waveforms and discriminator ON. Pulser re-connected to all fees via daisy chain. V=100v, I=8.36uA

 

Pulser peak widths (ch FWHM)
Entry  Fri Aug 12 15:12:37 2022, JM, TD, CARME measurements 9x
measurement 1 -string
intermediate (smaller) chamber - 2144 (mm) circumference,  measured half circumference 1072 mm 
outer (larger) chamber - 2160 (mm) circumference, measured 1/4 circumference 540mm
Entry  Fri Aug 12 09:06:57 2022, TD, JM, Noise tests pt2 30x

10.07 DSSSD bias -100V leakage current -8.65uA
Entry  Thu Aug 11 09:25:13 2022, JM, TD, Noise tests 14x

Moved pneumatic motor in and out several revolutions

Biased detector up to 100 V, I ~ 12.4 uA ambient temp c. 21 deg C
Entry  Wed Aug 10 10:33:03 2022, TD, ML, JM, NP, Meeting at YR09 to discuss options for CARME operations to February 2022 20220810_111638.jpg20220810_095036.jpg20220810_095150.jpg20220810_095159.jpg

Initial discussions of proposals to provide open CARME chamber and provide access to near and far detector chambers
Entry  Wed Aug 10 10:30:04 2022, TD, JM, Wednesday 10 August 4.PNG3.PNG2.png1.png

09.45 Found CARME electrical power off
Entry  Tue Aug 9 16:07:33 2022, JM, TD, Anydesk setup command line 
To log into appc218 desktop:
same login and password as to carme@atppc022.gsi.de

To start anydesk
Entry  Tue Aug 9 13:44:16 2022, TD, JM, Tuesday 9 August Capture_1.PNG20220809_163450.jpg20220809_135840.jpg20220809_135833.jpg20220809_135801.jpg

14.00 CARME vacuum c. 1.8e-10 mbar - see attachment 1
Entry  Thu Mar 3 15:14:21 2022, JM, OH, CARME packing up 
Pulser walkthrough taken for motor position 23.1mm and motor position 67.43mm.

Points taken at 30,50,70,90,110,130,150,170,190,210,230 for 23.1mm position and 230,210,190,170,150,130,110 for 67.43mm position.

Motors moved to fully OUT position and pin put back in. Current positions before closing program 19.1mm and 19.57mm. 
Entry  Wed Mar 2 22:29:48 2022, CB, SD, Last shift with beam 9x
22:30 Shift handed over. DAQ OK. Target OK. Beam OK.

 

00:22 Temperatures OK
Entry  Wed Mar 2 21:16:06 2022, JM, PM, Current status 
22:16

Temperature setpoint = 113k

Not observed noise burst again
Entry  Wed Mar 2 19:25:25 2022, JM, PM, Current status 10x
20:25

Observed short burst of low energy noise on aida1, lasted <30s (attachment 8).

Temperature setpoint = 113 K
Entry  Wed Mar 2 17:21:35 2022, JM, PM, Current status 8x
18:21

Temperature setpoint = 113k

Target density OK S1 varies between 2E-8 and 2.5E-8 mbar, E4 between 1E-9 and 5E-9 mbar. (slightly lower than previous check)
Entry  Wed Mar 2 14:15:16 2022, JM, PM, Current status 6x
15:15

Temperature setpoint = 113 K

Target density is OK for now. S1 vaies between 2E-8 and 3.5E-8 mbar. E4 between 1E-9 and 1E-8 mbar.
Entry  Wed Mar 2 09:38:50 2022, Spillmann, Uwe, ion source restarted 
 

detector position

out: 23.1mm
Entry  Wed Mar 2 06:00:49 2022, Spillmann, Uwe, waiting 
07:00
Target density is hovering between 2.0e-8 and 2.3e-8
Entry  Wed Mar 2 03:40:40 2022, David, George, Temperature Cycle 
04:40
Target density is hovering between 2.0e-8 and 2.3e-8, sometimes dipping below 2.0e-8

We will conduct a temperature walkthrough while there is no beam,
Entry  Wed Mar 2 01:24:48 2022, David, George, Ion Source Update 
02:25
Zoran was unable to ignite the ion source.

He has given some parameters to the control room so they can wiggle stuff around and try and ignite it.