554
|
Tue May 28 12:38:31 2024 |
TD, JM, CB | Run 2 - Alpha background run |
13.35 FEE64 temperatures OK - attachment 1
ADC data item rates OK - attachment 2
overall rate dominated by 2x hot channels aida15
per FEE64 Stat spectra - attachment 3
spectra consistent with April alpha background test
note high HEC data stats for aida12 asic#2 - can probably be fixed by ASIC control check
per 1.8.W spectra - 20us FSR - attachments 4-5
note 100kHz ripple observed for some FEE64s cf. https://elog.ph.ed.ac.uk/CARME/544
Run stopped 15:15 |
Attachment 1: Screenshot_from_2024-05-28_13-35-03.png
|
|
Attachment 2: Screenshot_from_2024-05-28_13-34-30.png
|
|
Attachment 3: Screenshot_from_2024-05-28_13-33-19.png
|
|
Attachment 4: Screenshot_from_2024-05-28_13-36-30.png
|
|
Attachment 5: Screenshot_from_2024-05-28_13-37-16.png
|
|
553
|
Mon May 27 15:25:08 2024 |
JM | Startup |
27/05/24
The carme-gsi computer has been moved from the server room into the shifter control room.
Startup of the DAQ looks OK. Settings loaded 2024Apr24
System wide checks OK. Aida16 clock status fails. Aida16 ADC calibration fails. Rest OK.
All FEEs look OK, we again see high rates in aida15 ~ 12k data items/sec, rate in other FEEs is 0.
Testing of the pulser widths has been done. Pulser widths will be uploaded soon.
Background run started. No beam, no target. File G22-201 and R2. Data being written is ~128 kb/s. Run will be left overnight, no night shift.
28/05/24
DAQ continues with alpha background run.
System wide checks OK. Aida16 clock status fails. Aida16 ADC calibration fails. Rest OK. Temps OK
Data can be seen in the spectrum browser on MIDAS. CARME monitoring code was started incorrectly yesterday. It has now be restarted and a small number of events are seen |
552
|
Fri May 10 21:23:35 2024 |
TD, CB, JM | 20Ne7+ test beam |
22.00
Carsten Brandau stopping e-target experiment Unattended beam overnight. No operators watching.
10^5 (nominal) 20Ne7+ at 380keV/u beam available
Carsten reports beam is unstable, often disappearing, and in bunched mode.
4x MSL type TTT14 DSSSDs not moving, locked in out position
Starting CARME MIDAS DAQ ASIC settings 2024Apr24-14.14.03
slow comparator 0x64 E
G&G Ortec 448 Pulser OFF
DSSSD bias & leakage currents - attachment 1
FEE64 temperatures OK - attachment 2
All system wide checks OK, WR timestamps OK - attachment 3
ADC data item stats - attachment 4
Rates dominated by two hot channels aida15 per FEE64 Stat spectra - attachment 5
per FEE64 1.8.L spectra - attachments 6-7 no obvious beam energy peak, continuum of energies from below beam energy to threshold
per FEE64 1.8.W spectra - attachments 8-9
22.55 Start data file APR24/R5 Merger, TapeServer etc - attachments 10-12
270k data items/s
23:29 Activated CARMESort script. See attachments 13-15.
No obvious beam or signal of any kind. Temperatures OK.
00:13 DAQ continues OK. System-wide check OK. Temps OK. Still no clear sign of beam.
01:03 Daq continues OK. System wide checks OK, Temps OK.
Only low energies observed in the energy spectrum. Looks a bit like the low energy noise observed in our previous runs with no/very few counts above what would be beam energy (~7.6 MeV)
Note the xy plots are not all orientated correctly (strips are correct in the sort code but root axis need to be flipped - I can;t remember how atm). The part of the plots with counts are those closest to the beam.
02:00 DAQ continues OK. System wide checks OK. Temps OK.
Spectra still looks the same. I have noticed the right hand side rate is higher than the left. EyEx cut spectrum also looks like much more counts outside of the cut.
03:40
DAQ continues. All checks and temps OK.
I can now see a small peak at 5 MeV in the bottom left dssd. This dssd also has the least number of counts in the low energy continuum.
I have logged back into grafana on x2go to get the number ions in the ring. Attachment 17
04:23 (05:23 EU)
DAQ stopped, merger stopped, tape server stopped. Bias OFF. FEEs turned OFF. Screen shots taken of the monitoring code plots - not yet uploaded.
Windows and servers remain up in case we want to do some more tests in the near future.
Attachment 18 shows beam intensity for total run time from Grafana |
Attachment 1: Screenshot_from_2024-05-10_22-31-48.png
|
|
Attachment 2: Screenshot_from_2024-05-10_22-32-52.png
|
|
Attachment 3: Screenshot_from_2024-05-10_22-33-45.png
|
|
Attachment 4: Screenshot_from_2024-05-10_22-34-59.png
|
|
Attachment 5: Screenshot_from_2024-05-10_22-37-12.png
|
|
Attachment 6: Screenshot_from_2024-05-10_22-38-32.png
|
|
Attachment 7: Screenshot_from_2024-05-10_22-39-48.png
|
|
Attachment 8: Screenshot_from_2024-05-10_22-40-38.png
|
|
Attachment 9: Screenshot_from_2024-05-10_22-41-24.png
|
|
Attachment 10: Screenshot_from_2024-05-10_22-56-53.png
|
|
Attachment 11: Screenshot_from_2024-05-10_22-56-20.png
|
|
Attachment 12: Screenshot_from_2024-05-10_22-56-35.png
|
|
Attachment 13: Screenshot_from_2024-05-10_23-28-37.png
|
|
Attachment 14: Screenshot_from_2024-05-10_23-28-45.png
|
|
Attachment 15: Screenshot_from_2024-05-10_23-28-51.png
|
|
Attachment 16: Screenshot_from_2024-05-11_00-12-43.png
|
|
Attachment 17: 20240511_025056.jpg
|
|
Attachment 18: 20240511_042236.jpg
|
|
550
|
Sun Apr 28 23:12:11 2024 |
TD | Monday 28 April |
00.09 DAQ continues data file R3_21
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
04.50 DAQ continues data file R3_22
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
09.41 DAQ continues data file R3_23
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 18
Merger, TapeServer etc - attachments 19-21
09.43 DAQ stopped
DSSSD bias OFF
FEE64 power OFF |
Attachment 1: Screenshot_from_2024-04-29_00-09-18.png
|
|
Attachment 2: Screenshot_from_2024-04-29_00-09-45.png
|
|
Attachment 3: Screenshot_from_2024-04-29_00-10-33.png
|
|
Attachment 4: Screenshot_from_2024-04-29_00-10-52.png
|
|
Attachment 5: Screenshot_from_2024-04-29_00-11-04.png
|
|
Attachment 6: Screenshot_from_2024-04-29_00-11-29.png
|
|
Attachment 7: Screenshot_from_2024-04-29_00-11-47.png
|
|
Attachment 8: Screenshot_from_2024-04-29_04-50-25.png
|
|
Attachment 9: Screenshot_from_2024-04-29_04-50-52.png
|
|
Attachment 10: Screenshot_from_2024-04-29_04-51-38.png
|
|
Attachment 11: Screenshot_from_2024-04-29_04-52-01.png
|
|
Attachment 12: Screenshot_from_2024-04-29_04-52-43.png
|
|
Attachment 13: Screenshot_from_2024-04-29_04-53-05.png
|
|
Attachment 14: Screenshot_from_2024-04-29_04-53-22.png
|
|
Attachment 15: Screenshot_from_2024-04-29_09-41-28.png
|
|
Attachment 16: Screenshot_from_2024-04-29_09-42-01.png
|
|
Attachment 17: Screenshot_from_2024-04-29_09-42-43.png
|
|
Attachment 18: Screenshot_from_2024-04-29_09-42-58.png
|
|
Attachment 19: Screenshot_from_2024-04-29_09-43-08.png
|
|
Attachment 20: Screenshot_from_2024-04-29_09-43-28.png
|
|
Attachment 21: Screenshot_from_2024-04-29_09-43-41.png
|
|
549
|
Sat Apr 27 23:16:02 2024 |
TD | Sunday 28 April |
00.12 DAQ continues data file R3_15
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
05.32 DAQ continues data file R3_16
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
11.27 DAQ continues data file R3_17
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 21
Merger, TapeServer etc - attachments 18-20
11.33 aida16 asic #2 2x Check ASIC control
aida16 asic #4 2x Check ASIC control
18.53 DAQ continues data file R3_19
DSSSD bias & leakage current OK - attachment 22
FEE64 temps OK - attachment 23
ADC data item stats OK - attachment 24
per FEE64 Rate spectra - attachment 25
Merger, TapeServer etc - attachments 26-28
per FEE64 1.8.H - attachments 29-30
per FEE64 1.8.L - attachments 31-32
per FEE64 1.8.W - 20us FSR - attachments 33-36
19.10 CRYRING ambient temperature per https://web-docs.gsi.de/~lestinsk/tempplot.php - attachment 37 |
Attachment 1: Screenshot_from_2024-04-28_00-11-59.png
|
|
Attachment 2: Screenshot_from_2024-04-28_00-12-25.png
|
|
Attachment 3: Screenshot_from_2024-04-28_00-13-20.png
|
|
Attachment 4: Screenshot_from_2024-04-28_00-14-35.png
|
|
Attachment 5: Screenshot_from_2024-04-28_00-15-03.png
|
|
Attachment 6: Screenshot_from_2024-04-28_00-15-40.png
|
|
Attachment 7: Screenshot_from_2024-04-28_00-15-20.png
|
|
Attachment 8: Screenshot_from_2024-04-28_05-32-48.png
|
|
Attachment 9: Screenshot_from_2024-04-28_05-33-11.png
|
|
Attachment 10: Screenshot_from_2024-04-28_05-34-03.png
|
|
Attachment 11: Screenshot_from_2024-04-28_05-34-36.png
|
|
Attachment 12: Screenshot_from_2024-04-28_05-34-50.png
|
|
Attachment 13: Screenshot_from_2024-04-28_05-35-08.png
|
|
Attachment 14: Screenshot_from_2024-04-28_05-35-22.png
|
|
Attachment 15: Screenshot_from_2024-04-28_11-27-15.png
|
|
Attachment 16: Screenshot_from_2024-04-28_11-27-35.png
|
|
Attachment 17: Screenshot_from_2024-04-28_11-27-52.png
|
|
Attachment 18: Screenshot_from_2024-04-28_11-28-48.png
|
|
Attachment 19: Screenshot_from_2024-04-28_11-29-02.png
|
|
Attachment 20: Screenshot_from_2024-04-28_11-29-13.png
|
|
Attachment 21: Screenshot_from_2024-04-28_11-31-05.png
|
|
Attachment 22: Screenshot_from_2024-04-28_18-53-09.png
|
|
Attachment 23: Screenshot_from_2024-04-28_18-53-32.png
|
|
Attachment 24: Screenshot_from_2024-04-28_18-53-54.png
|
|
Attachment 25: Screenshot_from_2024-04-28_18-54-40.png
|
|
Attachment 26: Screenshot_from_2024-04-28_18-54-50.png
|
|
Attachment 27: Screenshot_from_2024-04-28_18-55-06.png
|
|
Attachment 28: Screenshot_from_2024-04-28_18-55-17.png
|
|
Attachment 29: Screenshot_from_2024-04-28_19-00-46.png
|
|
Attachment 30: Screenshot_from_2024-04-28_19-01-27.png
|
|
Attachment 31: Screenshot_from_2024-04-28_18-59-12.png
|
|
Attachment 32: Screenshot_from_2024-04-28_19-00-08.png
|
|
Attachment 33: Screenshot_from_2024-04-28_19-01-57.png
|
|
Attachment 34: Screenshot_from_2024-04-28_19-02-21.png
|
|
Attachment 35: Screenshot_from_2024-04-28_19-02-53.png
|
|
Attachment 36: Screenshot_from_2024-04-28_19-03-18.png
|
|
Attachment 37: CRY_temps.PNG
|
|
548
|
Fri Apr 26 23:41:16 2024 |
TD | Saturday 27 April |
00.34 DAQ continues data file R3_9
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
06.41 DAQ continues data file R3_10
DSSSD bias & leakage current OK - attachment 8
FEE64 temps OK - attachment 9
ADC data item stats OK - attachment 10
per FEE64 Rate spectra - attachment 11
Merger, TapeServer etc - attachments 12-14
10.56 DAQ continues data file R3_11
DSSSD bias & leakage current OK - attachment 15
FEE64 temps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 18
Merger, TapeServer etc - attachments 19-21
14.33 DAQ continues data file R3_12
DSSSD bias & leakage current OK - attachment 22
FEE64 temps OK - attachment 23
ADC data item stats OK - attachment 24
per FEE64 Rate spectra - attachment 25
Merger, TapeServer etc - attachments 26-28
18.31 DAQ continues data file R3_13
DSSSD bias & leakage current OK - attachment 29
FEE64 temps OK - attachment 30
ADC data item stats OK - attachment 31
per FEE64 Rate spectra - attachment 32
per FEE64 1.8.L spectra - attachments 33-34
Merger, TapeServer etc - attachments 35-37 |
Attachment 1: Screenshot_from_2024-04-27_00-34-52.png
|
|
Attachment 2: Screenshot_from_2024-04-27_00-35-25.png
|
|
Attachment 3: Screenshot_from_2024-04-27_00-36-07.png
|
|
Attachment 4: Screenshot_from_2024-04-27_00-36-34.png
|
|
Attachment 5: Screenshot_from_2024-04-27_00-36-49.png
|
|
Attachment 6: Screenshot_from_2024-04-27_00-37-14.png
|
|
Attachment 7: Screenshot_from_2024-04-27_00-37-37.png
|
|
Attachment 8: Screenshot_from_2024-04-27_06-41-34.png
|
|
Attachment 9: Screenshot_from_2024-04-27_06-42-06.png
|
|
Attachment 10: Screenshot_from_2024-04-27_06-42-48.png
|
|
Attachment 11: Screenshot_from_2024-04-27_06-43-08.png
|
|
Attachment 12: Screenshot_from_2024-04-27_06-43-19.png
|
|
Attachment 13: Screenshot_from_2024-04-27_06-43-36.png
|
|
Attachment 14: Screenshot_from_2024-04-27_06-43-50.png
|
|
Attachment 15: Screenshot_from_2024-04-27_10-55-54.png
|
|
Attachment 16: Screenshot_from_2024-04-27_10-56-21.png
|
|
Attachment 17: Screenshot_from_2024-04-27_10-56-38.png
|
|
Attachment 18: Screenshot_from_2024-04-27_10-57-26.png
|
|
Attachment 19: Screenshot_from_2024-04-27_10-57-45.png
|
|
Attachment 20: Screenshot_from_2024-04-27_10-58-04.png
|
|
Attachment 21: Screenshot_from_2024-04-27_10-58-16.png
|
|
Attachment 22: Screenshot_from_2024-04-27_14-33-33.png
|
|
Attachment 23: Screenshot_from_2024-04-27_14-34-04.png
|
|
Attachment 24: Screenshot_from_2024-04-27_14-34-52.png
|
|
Attachment 25: Screenshot_from_2024-04-27_14-35-08.png
|
|
Attachment 26: Screenshot_from_2024-04-27_14-35-19.png
|
|
Attachment 27: Screenshot_from_2024-04-27_14-35-50.png
|
|
Attachment 28: Screenshot_from_2024-04-27_14-35-34.png
|
|
Attachment 29: Screenshot_from_2024-04-27_18-31-01.png
|
|
Attachment 30: Screenshot_from_2024-04-27_18-31-22.png
|
|
Attachment 31: Screenshot_from_2024-04-27_18-31-40.png
|
|
Attachment 32: Screenshot_from_2024-04-27_18-32-27.png
|
|
Attachment 33: Screenshot_from_2024-04-27_18-33-04.png
|
|
Attachment 34: Screenshot_from_2024-04-27_18-33-47.png
|
|
Attachment 35: Screenshot_from_2024-04-27_18-34-04.png
|
|
Attachment 36: Screenshot_from_2024-04-27_18-34-22.png
|
|
Attachment 37: Screenshot_from_2024-04-27_18-34-44.png
|
|
547
|
Fri Apr 26 07:05:01 2024 |
TD | Friday 26 April |
08.02 DAQ continues data file R1_14
DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC data item stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachments 5-7
10.40 Close file R1 and open file R2
Switch on pulser (relay line 50Hz)
per FEE64 Rate spectra - attachment 8
Check ASIC load x2 for aida09, aida10, aida12, aida15 aida16
per FEE64 Rate spectra - attachment 12
status quo ante
Pulser walkthrough
Pulser settings per https://elog.ph.ed.ac.uk/CARME/544
Amplituides 70,000-10,000 @ 10,000 step
per FEE64 1.8.L spectra - attachments 9-10
per FEE64 Rate spectra - attachment 11
11.05 Pulser OFF
Close file R2, open file R3
zero all histograms stats
background alpha run continues
20.33 DAQ continues data file R3_8
DSSSD bias & leakage current OK - attachment 13
FEE64 temps OK - attachment 14
ADC data item stats OK - attachment 15
per FEE64 Rate spectra - attachment 16
Merger, TapeServer etc - attachments 1-19
CAEN data log stopped 00:21 Friday 26 April
pi@nnrpi1:~/Programs/caenlogger $ caenlogger --config caenlogger_config_gsi.toml
2024-04-25 15:25:16.194 | INFO | caenlogger.__main__:main:117 - Config file provided.
Traceback (most recent call last):
File "/home/pi/.local/bin/caenlogger", line 10, in <module>
sys.exit(main())
File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 135, in main
curses.wrapper(process, config_dic)
File "/usr/lib/python3.7/curses/__init__.py", line 94, in wrapper
return func(stdscr, *args, **kwds)
File "/home/pi/.local/lib/python3.7/site-packages/caenlogger/__main__.py", line 57, in process
Vmon = [ f for f in HV[5].strip().split(" ") if f ]
IndexError: list index out of range
Old log gzip'd and moved to directory ~/logs
[npg@carme-gsi ~]$ mv caen_current.dat.gz logs/0031260424-caen_current.dat.gz
20.45 Restarted logger program |
Attachment 1: Screenshot_from_2024-04-26_08-02-37.png
|
|
Attachment 2: Screenshot_from_2024-04-26_08-02-57.png
|
|
Attachment 3: Screenshot_from_2024-04-26_08-03-17.png
|
|
Attachment 4: Screenshot_from_2024-04-26_08-03-56.png
|
|
Attachment 5: Screenshot_from_2024-04-26_08-04-06.png
|
|
Attachment 6: Screenshot_from_2024-04-26_08-04-25.png
|
|
Attachment 7: Screenshot_from_2024-04-26_08-04-41.png
|
|
Attachment 8: Screenshot_from_2024-04-26_10-38-00.png
|
|
Attachment 9: Screenshot_from_2024-04-26_11-01-53.png
|
|
Attachment 10: Screenshot_from_2024-04-26_11-02-51.png
|
|
Attachment 11: Screenshot_from_2024-04-26_11-03-23.png
|
|
Attachment 12: Screenshot_from_2024-04-26_10-43-19.png
|
|
Attachment 13: Screenshot_from_2024-04-26_20-33-24.png
|
|
Attachment 14: Screenshot_from_2024-04-26_20-33-49.png
|
|
Attachment 15: Screenshot_from_2024-04-26_20-34-30.png
|
|
Attachment 16: Screenshot_from_2024-04-26_20-36-04.png
|
|
Attachment 17: Screenshot_from_2024-04-26_20-36-17.png
|
|
Attachment 18: Screenshot_from_2024-04-26_20-36-37.png
|
|
Attachment 19: Screenshot_from_2024-04-26_20-36-49.png
|
|
546
|
Thu Apr 25 02:31:25 2024 |
TD | Thursday 25 April |
03.27 DAQ continues - file APR24/R1_7
DSSSD bias & leakage current OK - attachment 1
ambient temperature 16.1 deg C
FEE64 temperatures OK - attachment 2
ADC data item stats OK - attachment 3
per n+n FEE64 1.8.L spectra - attachment 4
per FEE64 Stat spectra - attachment 5
Merger, TapeServer etc - attachments 6-8
10.19 DAQ continues - file APR24/R1_8
DSSSD bias & leakage current OK - attachment 9
ambient temperature 16.2 deg C
FEE64 temperatures OK - attachment 10
ADC data item stats OK - attachment 11
per FEE64 Stat spectra - attachment 12
Merger, TapeServer etc - attachments 13-15
NetVar merge variables - attachment 16
14.44 DAQ continues - file APR24/R1_10
DSSSD bias & leakage current OK - attachment 17
ambient temperature 16.5 deg C
FEE64 temperatures OK - attachment 18
ADC data item stats OK - attachment 19
per FEE64 Stat spectra - attachment 20
some HEC data has appeared
Merger, TapeServer etc - attachments 21-23
19.12 DAQ continues - file APR24/R1_11
DSSSD bias & leakage current OK - attachment 24
ambient temperature 16.5 deg C
FEE64 temperatures OK - attachment 25
ADC data item stats OK - attachment 26
per FEE64 Stat spectra - attachment 27
per FEE64 1.8.L spectra - attachments 28-29
Merger, TapeServer etc - attachments 30-32
23.14 DAQ continues - file APR24/R1_12
DSSSD bias & leakage current OK - attachment 33
ambient temperature 16.1 deg C
FEE64 temperatures OK - attachment 34
ADC data item stats OK - attachment 35
per FEE64 Stat spectra - attachment 36
Merger, TapeServer etc - attachments 37-39 |
Attachment 1: Screenshot_from_2024-04-25_03-26-58.png
|
|
Attachment 2: Screenshot_from_2024-04-25_03-27-48.png
|
|
Attachment 3: Screenshot_from_2024-04-25_03-28-19.png
|
|
Attachment 4: Screenshot_from_2024-04-25_03-28-41.png
|
|
Attachment 5: Screenshot_from_2024-04-25_03-32-43.png
|
|
Attachment 6: Screenshot_from_2024-04-25_03-30-13.png
|
|
Attachment 7: Screenshot_from_2024-04-25_03-30-37.png
|
|
Attachment 8: Screenshot_from_2024-04-25_03-30-55.png
|
|
Attachment 9: Screenshot_from_2024-04-25_10-19-09.png
|
|
Attachment 10: Screenshot_from_2024-04-25_10-19-31.png
|
|
Attachment 11: Screenshot_from_2024-04-25_10-19-54.png
|
|
Attachment 12: Screenshot_from_2024-04-25_10-20-14.png
|
|
Attachment 13: Screenshot_from_2024-04-25_10-20-26.png
|
|
Attachment 14: Screenshot_from_2024-04-25_10-20-53.png
|
|
Attachment 15: Screenshot_from_2024-04-25_10-21-22.png
|
|
Attachment 16: Screenshot_from_2024-04-25_10-21-45.png
|
|
Attachment 17: Screenshot_from_2024-04-25_14-44-05.png
|
|
Attachment 18: Screenshot_from_2024-04-25_14-44-29.png
|
|
Attachment 19: Screenshot_from_2024-04-25_14-44-49.png
|
|
Attachment 20: Screenshot_from_2024-04-25_14-45-51.png
|
|
Attachment 21: Screenshot_from_2024-04-25_14-46-35.png
|
|
Attachment 22: Screenshot_from_2024-04-25_14-46-53.png
|
|
Attachment 23: Screenshot_from_2024-04-25_14-47-05.png
|
|
Attachment 24: Screenshot_from_2024-04-25_19-12-30.png
|
|
Attachment 25: Screenshot_from_2024-04-25_19-13-01.png
|
|
Attachment 26: Screenshot_from_2024-04-25_19-13-39.png
|
|
Attachment 27: Screenshot_from_2024-04-25_19-14-02.png
|
|
Attachment 28: Screenshot_from_2024-04-25_19-14-40.png
|
|
Attachment 29: Screenshot_from_2024-04-25_19-15-24.png
|
|
Attachment 30: Screenshot_from_2024-04-25_19-15-58.png
|
|
Attachment 31: Screenshot_from_2024-04-25_19-16-12.png
|
|
Attachment 32: Screenshot_from_2024-04-25_19-16-30.png
|
|
Attachment 33: Screenshot_from_2024-04-25_23-14-01.png
|
|
Attachment 34: Screenshot_from_2024-04-25_23-14-23.png
|
|
Attachment 35: Screenshot_from_2024-04-25_23-14-41.png
|
|
Attachment 36: Screenshot_from_2024-04-25_23-16-04.png
|
|
Attachment 37: Screenshot_from_2024-04-25_23-16-12.png
|
|
Attachment 38: Screenshot_from_2024-04-25_23-16-25.png
|
|
Attachment 39: Screenshot_from_2024-04-25_23-16-42.png
|
|
545
|
Wed Apr 24 13:18:09 2024 |
TD | Examples of poor CARME cable management/routing |
Have observed some instances of poor CARME cable management/routing
Attachment 1 - SAES D-2000 ion pump HV cable (netal braid) transiting FEE64 cabling
Attachment 2 - CARME motor controller cable (grey plastic) transiting FEE64 cabling
General check and tidying up required. |
Attachment 1: 20240424_125858.jpg
|
|
Attachment 2: 20240424_125929.jpg
|
|
544
|
Wed Apr 24 12:48:35 2024 |
TD | Wednesday 24 April |
Replace AIDA ASIC mezzanine of aida01
13.43 DSSSD bias & leakage current OK - attachment 1
ambient temperature 16.5 deg C
FEE64 temperatures OK - attachment 2
All system wide checks OK
WR timestamps OK - attachment 3
ADC data item stats OK - attachment 4
per FEE64 Rate spectra - attachment 5
c. 10 strips (of 1024) not producing data
most missing strips are from aida05 - misaligned or damaged adaptor PCB?
per p+n FEE64 1.8.L spectra - attachment 6
aida01 pulser peak width 75 ch FWHM
common x/y scale => peak height proxy for peak width
per n+n FEE64 1.8.L spectra - attachment 7
aida01 pulser peak width 70 ch FWHM
per FEE64 1.8.W spectra - 20us FSR - attachments 8-11
Summary
All FEE64s appear to be working (except aida05 which has c. 8 missing channels) with pulser - which
validates the FEE64, ASICs and adaptor PCB.
Electronic noise c. 50keV FWHM for aida01 & aida03 - other FEE64s better/worse.
Preamplifier noise appears to be similar for all FEE64s which may suggest an issue with the test signal chain
Note
1) e-target is starting up
2) have identified some instances of poor CARME cable management/routing see https://elog.ph.ed.ac.uk/CARME/545
EG&G Ortec 448 Pulser
Amplitude 50,000
Normalise 5.00
x5 attenuator IN
t_r 100ns
tau_d 50us
Polarity +
Frequency relay line (50Hz)
Cooknell SA1 Summing Amplifier
inverted output to test - daisy chain
Current ASIC settings saved to 2024Apr24-14.14.03
14.48 Pulser OFF
All histograms & stats zero'd
LEC slow comparator 0x64 -> 0xff
HEC fast comparator 0x2 -> 0x5
background alpha run to validate signal path from DSSSD to FEE64 adaptor PCB
22.18 Start Merger & TapeServer - attachments 12-14
DSSSD bias & leakage current OK - attachment 21
ambient temperature 16.0 deg C
FEE64 temperatures OK - attachment 15
WR timestamps OK - attachment 16
ADC data item stats OK - attachment 17
per FEE64 Rate spectra - attachment 18
per p+n FEE64 1.8.L spectra - attachments 19-20 |
Attachment 1: Screenshot_from_2024-04-24_13-43-29.png
|
|
Attachment 2: Screenshot_from_2024-04-24_13-44-02.png
|
|
Attachment 3: Screenshot_from_2024-04-24_13-45-01.png
|
|
Attachment 4: Screenshot_from_2024-04-24_13-45-28.png
|
|
Attachment 5: Screenshot_from_2024-04-24_13-45-46.png
|
|
Attachment 6: Screenshot_from_2024-04-24_13-47-59.png
|
|
Attachment 7: Screenshot_from_2024-04-24_13-52-50.png
|
|
Attachment 8: Screenshot_from_2024-04-24_13-55-02.png
|
|
Attachment 9: Screenshot_from_2024-04-24_13-55-32.png
|
|
Attachment 10: Screenshot_from_2024-04-24_13-56-48.png
|
|
Attachment 11: Screenshot_from_2024-04-24_13-55-59.png
|
|
Attachment 12: Screenshot_from_2024-04-24_22-19-55.png
|
|
Attachment 13: Screenshot_from_2024-04-24_22-20-16.png
|
|
Attachment 14: Screenshot_from_2024-04-24_22-20-30.png
|
|
Attachment 15: Screenshot_from_2024-04-24_22-21-58.png
|
|
Attachment 16: Screenshot_from_2024-04-24_22-22-22.png
|
|
Attachment 17: Screenshot_from_2024-04-24_22-22-57.png
|
|
Attachment 18: Screenshot_from_2024-04-24_22-23-27.png
|
|
Attachment 19: Screenshot_from_2024-04-24_22-24-37.png
|
|
Attachment 20: Screenshot_from_2024-04-24_22-25-30.png
|
|
Attachment 21: Screenshot_from_2024-04-24_22-27-58.png
|
|
543
|
Tue Apr 23 17:44:41 2024 |
TD | Tuesday 23 April |
18.43 ASIC settings 2024Feb08-15.59.09
aida06 pulser peak width 66 ch FWHM |
Attachment 1: Screenshot_from_2024-04-23_18-53-39.png
|
|
Attachment 2: Screenshot_from_2024-04-23_18-56-31.png
|
|
Attachment 3: Screenshot_from_2024-04-23_18-58-49.png
|
|
Attachment 4: Screenshot_from_2024-04-23_18-59-18.png
|
|
Attachment 5: Screenshot_from_2024-04-23_19-02-02.png
|
|
Attachment 6: Screenshot_from_2024-04-23_19-05-12.png
|
|
Attachment 7: Screenshot_from_2024-04-23_19-05-42.png
|
|
Attachment 8: Screenshot_from_2024-04-23_19-06-15.png
|
|
Attachment 9: Screenshot_from_2024-04-23_19-10-40.png
|
|
Attachment 10: Screenshot_from_2024-04-23_19-14-23.png
|
|
Attachment 11: Screenshot_from_2024-04-23_19-16-12.png
|
|
Attachment 12: Screenshot_from_2024-04-23_19-16-46.png
|
|
542
|
Fri Apr 19 02:47:59 2024 |
TD | Friday 19 April |
03.45
10.01
10.05 DSSSD bias OFF
FEE64 power OFF |
Attachment 1: Screenshot_from_2024-04-19_03-45-09.png
|
|
Attachment 2: Screenshot_from_2024-04-19_03-46-43.png
|
|
Attachment 3: Screenshot_from_2024-04-19_03-47-13.png
|
|
Attachment 4: Screenshot_from_2024-04-19_03-48-48.png
|
|
Attachment 5: Screenshot_from_2024-04-19_10-53-30.png
|
|
Attachment 6: Screenshot_from_2024-04-19_10-53-54.png
|
|
Attachment 7: Screenshot_from_2024-04-19_10-54-37.png
|
|
Attachment 8: Screenshot_from_2024-04-19_10-57-32.png
|
|
Attachment 9: Screenshot_from_2024-04-19_10-58-15.png
|
|
Attachment 10: Screenshot_from_2024-04-19_10-59-15.png
|
|
Attachment 11: Screenshot_from_2024-04-19_11-00-45.png
|
|
Attachment 12: Screenshot_from_2024-04-19_11-04-21.png
|
|
541
|
Thu Apr 18 13:34:06 2024 |
TD, JG | Thursday 18 April |
14.30
per FEE64 1.8.L spectra
aida11 pulser peak width 52 ch FWHM
14.45 EG&G Ortec 448 Pulser OFF
all stats & histograms zero'd
alpha background
22.00 DSSSD bias and leakage current OK - attachment 10
FEE64 temperatures OK - attachment 11
ADC data item stats - attachment 12
per FEE64 Stat spectra - attachment 13
Comparison of attachment 9 (per FEE64 Rate spectra with pulser) indicates significant issues (downstream of adaptor PCB) for DSSSD #1
Possible issues asics #3 aida01 and possible adaptor PCB misalignment aida05 |
Attachment 1: Screenshot_from_2024-04-18_14-22-41.png
|
|
Attachment 2: Screenshot_from_2024-04-18_14-23-10.png
|
|
Attachment 3: Screenshot_from_2024-04-18_14-23-51.png
|
|
Attachment 4: Screenshot_from_2024-04-18_14-24-18.png
|
|
Attachment 5: Screenshot_from_2024-04-18_14-27-33.png
|
|
Attachment 6: Screenshot_from_2024-04-18_14-28-26.png
|
|
Attachment 7: Screenshot_from_2024-04-18_14-31-14.png
|
|
Attachment 8: Screenshot_from_2024-04-18_14-32-31.png
|
|
Attachment 9: Screenshot_from_2024-04-18_14-43-27.png
|
|
Attachment 10: Screenshot_from_2024-04-18_21-57-51.png
|
|
Attachment 11: Screenshot_from_2024-04-18_21-58-31.png
|
|
Attachment 12: Screenshot_from_2024-04-18_21-59-11.png
|
|
Attachment 13: Screenshot_from_2024-04-18_21-59-35.png
|
|
540
|
Wed Mar 6 10:47:11 2024 |
JG, TD | Wednesday 6 March - PEXARIA5 WR test |
Courtesy Nik Kurz, JG has installed a PEXARIA5 PCIe card adjacent to CARME - BuTIS single-mode fibre input
and HDMI output to root MACB input for distribution to the other MACBs and FEE64s.
The PEXARIA5 card provides equivalent functionality to the VETAR2 VME module that we have used to date.
Further information https://www.gsi.de/fileadmin/EE/Module/EXPLODER/pexaria5_14.pdf
Cooling water ON
Via Anydesk startup MIDAS and FEE64s
Power ON
DSSSD HV OFF ( not required for WR test )
FEE64 temperatures OK - attachment 1
All system wide checks OK
Info code 4 & 5 stats OK - attachments 2 & 3
10:48:46 WR timestamps OK - attachment 4
Timestamp (ns) converted to (s) corresponds to 09.49.22 GMT 6.3.24 which appears to be correct
11.00 Power OFF |
Attachment 1: temps.PNG
|
|
Attachment 2: stats_1.PNG
|
|
Attachment 3: stats_2.PNG
|
|
Attachment 4: wr_0949.PNG
|
|
539
|
Wed Feb 21 07:38:32 2024 |
TD | Wedneday 21 February |
10.54 23.2.24 Bias OFF |
Attachment 1: Screenshot_from_2024-02-20_18-40-08.png
|
|
Attachment 2: Screenshot_from_2024-02-20_21-30-08.png
|
|
Attachment 3: Screenshot_from_2024-02-21_01-00-13.png
|
|
Attachment 4: Screenshot_from_2024-02-21_05-10-07.png
|
|
Attachment 5: Screenshot_from_2024-02-21_08-30-06.png
|
|
Attachment 6: Screenshot_from_2024-02-21_20-45-58.png
|
|
Attachment 7: Screenshot_from_2024-02-21_20-46-12.png
|
|
Attachment 8: Screenshot_from_2024-02-22_00-51-21.png
|
|
Attachment 9: Screenshot_from_2024-02-22_14-02-29.png
|
|
Attachment 10: Screenshot_from_2024-02-22_14-02-44.png
|
|
Attachment 11: Screenshot_from_2024-02-22_19-00-08.png
|
|
Attachment 12: Screenshot_from_2024-02-22_19-00-31.png
|
|
Attachment 13: Screenshot_from_2024-02-23_11-53-32.png
|
|
Attachment 14: Screenshot_from_2024-02-23_11-53-45.png
|
|
Attachment 15: Capture_10.55.PNG
|
|
Attachment 16: Capture_18.00.PNG
|
|
Attachment 17: Capture_13.04.PNG
|
|
Attachment 18: Capture_23.52.PNG
|
|
Attachment 19: Capture_19.46.PNG
|
|
Attachment 20: Capture_07.30.PNG
|
|
Attachment 21: Capture_04.10.PNG
|
|
Attachment 22: Capture_00.00.PNG
|
|
Attachment 23: Capture_20.30.PNG
|
|
Attachment 24: Capture_17.40.PNG
|
|
538
|
Tue Feb 20 14:12:32 2024 |
JM | Shutdown |
CARME DAQ shutdown. FEEs turned OFF and all MIDAS server windows closed.
Detector bias turned OFF.
Final leakage current plot - attachment 1 |
Attachment 1: Screenshot_from_2024-02-20_15-11-40.png
|
|
537
|
Tue Feb 20 13:20:44 2024 |
OF, AG, JG, ML | R48 status check |
Doing afternoon check. Checked the leakage currents, all ok. Attachment 1
Temperatures ok, attchment 2
System wide check, all correct.
Statistics ok (as far as we can tell) attachment 3
Spectrum browser ok, attachment 4
Checked merger, spinner spinning...
Beam current is around 2.2 E7 and the target dencity is 6.3E11 cm2. |
Attachment 1: Screenshot_from_2024-02-20_14-22-05.png
|
|
Attachment 2: Screenshot_from_2024-02-20_14-22-49.png
|
|
Attachment 3: Screenshot_from_2024-02-20_14-29-39.png
|
|
Attachment 4: Screenshot_from_2024-02-20_14-34-55.png
|
|
536
|
Tue Feb 20 09:57:57 2024 |
OF, AG, ML | Run 48 status check |
Doing morning check. Checked the leakage currents, all ok. Attachment 1
Temperatures ok, attchment 2
System wide check, all correct.
Statistics ok (as far as we can tell) attachment 3
Spectrum browser ok, attachment 4
Checked merger, spinner spinning...
Attachment 5 shows the BPM scope (i.e. induced signals from the ion buchnes) for the duration of injection, bunching, acceleration, debunching.
Beam current is around 2.5E7 and the target dencity is 6.3E11 cm2. |
Attachment 1: Screenshot_from_2024-02-20_11-06-48.png
|
|
Attachment 2: Screenshot_from_2024-02-20_11-08-05.png
|
|
Attachment 3: Screenshot_from_2024-02-20_11-12-26.png
|
|
Attachment 4: Screenshot_from_2024-02-20_11-13-58.png
|
|
Attachment 5: 2024-02-20_11-37-46-304.png
|
|
535
|
Tue Feb 20 09:51:37 2024 |
JM | Run 48 beam on target |
Run 48 started |
534
|
Tue Feb 20 08:41:08 2024 |
OF, AG | still no beam CRYRING |
We have mosty empty injections into CRYRING. Only sporadically the beam with good intensity is injected.
Michael Lestinsky is currently working on the problem. |