AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DTAS, Page 4 of 8  ELOG logo
ID Date Author Subjectdown Text Attachments
  109   Mon Jun 10 04:18:24 2019 Ale, JoseNew Configuration FileFile:  20190610_1145_Conf_DTAS.xlsx

Several changes and corrections
 20190610_1145_Conf_DTAS.xlsx 
  115   Mon Jun 10 12:48:01 2019 Ale, JoseNew Config fileConf file with new calibration:
20190610_2035_Conf_DTAS.xlsx
 6x 
  113   Mon Jun 10 10:44:36 2019 Ale, JoseNew Conf file with new calibrationFile: 20190610_1835_Conf_DTAS.xlsx   
  126   Sun Jun 16 01:36:08 2019 VictorMm 100Sn beam   Mm_beam_ON_100Sn_runs9-11.pngMm_beam_ON_100Sn_runs9-11_zoom.pngMm_beam_ON_100Sn_runs9-11.CMm_beam_ON_100Sn_runs9-11_linear.png 
  141   Mon Jun 17 06:28:06 2019 VictorMC number of implants           Counts in DTAS
Proposal   2730 
4 days     888
 MC_100Sn_days.png 
  96   Tue Jun 4 06:25:51 2019 A. AlgoraLead shielding was "upgraded"With the help of Tom the additional lead
pieces were put. So now the hole in the lead
shielding matches the hole in the polyethylene
  
  44   Fri May 24 07:57:51 2019 A. AlgoraLead shielding heigth increasedThe aluminium plate of 3 cm thickness arrived
and the lead shielding was dismounted and
mounted again. We left a narrower hole in
  
  66   Wed May 29 02:07:20 2019 A. AlgoraIrradiation for 24NaIrradiation of two pieces of aluminium
of 80 mm x 40 mm x 10 mm will be performed
at the second BigRips dipole.
  
  2   Tue May 14 13:16:33 2019 JLTHardware setup   11x 
  56   Mon May 27 07:34:58 2019 A. AlgoraHV statusEMPTY00    │  
0.0 V 1500.0 uA    0.5 V   
0.5 uA Off               
  
  5   Wed May 15 06:53:52 2019 Nacher Kiss AlgoraHV settingEMPTY00      │0.0   
V 1500.0 uA    0.5 V   
0.5 uA Off               
  
  111   Mon Jun 10 09:58:42 2019 Jose, AleGain matchingWe have corrected small gain changes by changing
the HV of detectors. Attached are the new
values
 Screenshot_from_2019-06-10_17-58-00.pngScreenshot_from_2019-06-10_17-57-56.png 
  67   Wed May 29 07:04:19 2019 A. AlgoraF11 plastic connectedF11 plastic has been connected to our dacq
as it was in the earlier BRIKEN setting.

The detector cables were followed
  
  7   Wed May 15 08:11:46 2019 Tolosa, Nacher, Algora, KissEnergy resolutions
Using getSigmaCal.cxx macro to check energy
resolutions...
 getSigmaCal.cxxcalFit5.root 
  22   Mon May 20 09:39:23 2019 A. AlgoraDynode 08 threshold changedDynode 08 threshold was changed from 675
to 790. Now the rate in this detector is
fine.
  
  14   Thu May 16 06:59:51 2019 Algora Kiss NacherDet 3Det 3 moved, both Anode and Dynode. So
we have changed the HV cable to test if there
are no more jumps. We used cable 9 and it
  
  4   Wed May 15 06:40:16 2019 Algora, Kiss, Nacher DTAS aligned and calibratedSignal cables (long cables, from preamp
to digitizer) of channels 13 and 16 were
changed. For the moment they have not been
 Screenshot_from_2019-05-15_14-29-57.pngScreenshot_from_2019-05-15_14-30-57.pngScreenshot_from_2019-05-15_14-31-25.pngScreenshot_from_2019-05-15_14-31-55.png 
  25   Tue May 21 02:20:26 2019 A. AlgoraCs measurement, Cs401, 4763Start: 10:25

Stop: 11:26

lmd: Cs137_source_201905211025_052.dl
 201905211126_137Cs.root 
  102   Fri Jun 7 09:37:15 2019 The same teamCs for the AIDA synch testStart: 17:41

Stop: 18:17

AIDA files: R19_1 (@17:57)
  
  103   Fri Jun 7 12:35:14 2019 Jorge, AlvaroCorrelation time AIDA_DTAS for 60Co sourceFiles at mars /home/briken/190607AidaTasTest60Co  AidaDTAS60CoTest.pdf 
ELOG V3.1.4-unknown