ID |
Date |
Author |
Subject |
Text |
 |
114
|
Sat Nov 11 23:30:25 2017 |
RG MB | Run 101 |
Header: CH2 #30+25, Beam energy 4.0
MeV/u
Ender:
====================================================
Run
number : 101
Date : 12/11/2017
Start |
|
115
|
Sun Nov 12 01:28:26 2017 |
RG MB | Run 102 - Junk | Header: CH2 #30+25, Beam energy 4.0 MeV/u
Ender: Run stopped short as the RF cavity
tripped
|
|
116
|
Sun Nov 12 01:46:23 2017 |
RG MB | Run 103 | Header: CH2 #30+25, beam energy 4.0 MeV/u
Ender: Run stopped as the beam went off.
Noticed on the HI det scalar
|
|
117
|
Sun Nov 12 04:22:57 2017 |
RG MB | Run 104 | Header: CH2 #30+25, beam energy 4.0 MeV/u
Ender:
====================================================
|
|
118
|
Sun Nov 12 06:23:36 2017 |
RG MB | Run 105 | Header: CH2 #30+25, beam energy 4.0 MeV/u
Ender: run ends OK to change beam energy
from 4.0MeV/u to 4.29MeV/u
|
|
175
|
Thu Nov 16 11:20:51 2017 |
RG CLW MD | Run 162 -HI det calibration | Header: 4alpha source - Heavy Ion detector
calibration
Ender:
|
|
176
|
Thu Nov 16 15:14:39 2017 |
RG CLW MD | Run 165 Pulse Walkthrough dE p-side | Header: Pulser walkthrough, dE p-side
Ender: positive pulser, fall time 1ms, delay
250 ns, 1.6 V in steps of 0.2, 250 Hz
|
|
177
|
Thu Nov 16 15:24:42 2017 |
RG CLW MD | Run 166 Pulse Walkthrough dE n-side | Header: Pulser walkthrough, dE n-side
Ender: negative pulser, rise time 0.05 us,
fall time 1ms, delay .5 us,ref INT, width |
|
178
|
Thu Nov 16 15:33:24 2017 |
RG CLW MD | Run 168 Pulse Walkthrough E p-side | Header: Pulser walkthrough, E p-side
Ender: positive pulser, fall time 1ms, delay
250 ns, 6 V in steps of 0.5, 250 Hz
|
|
180
|
Thu Nov 16 15:43:48 2017 |
RG CLW MD | Run 169 Pulse Walkthrough E n-side | Header: Pulser walkthrough, E n-side
Ender: negative pulser, rise time 0.05 us,
fall time 1ms, delay .5 us,ref INT, width |
|
181
|
Thu Nov 16 15:57:29 2017 |
RG CLW MD | Run 170 Pulse Walkthrough HI p-side | Header: Pulser walkthrough, HI p-side
Ender: positive pulser, fall time 1ms, delay
250 ns, 10 V in steps of 1, 250 Hz
|
|
182
|
Thu Nov 16 16:06:07 2017 |
RG CLW MD | Run 171 Pulse Walkthrough HI n-side | Header: Pulser walkthrough, HI n-side
Ender: negative pulser, rise time 0.05 us,
fall time 1ms, delay .5 us,ref INT, width |
|
183
|
Thu Nov 16 16:14:04 2017 |
RG CLW MD | Run 172 Pulse Walkthrough HI n-side | Header: Pulser walkthrough, HI n-side
Ender: Change to digital pulser to check
as non-linearity was observed at low amplitudes. |
|
184
|
Thu Nov 16 16:24:29 2017 |
RG CLW MD | Run 173 Pulse Walkthrough HI n-side | Header: Pulser walkthrough, HI n-side, trigger
on HI detector this time
Ender: Change to digital pulser to check |
|
169
|
Wed Nov 15 11:33:31 2017 |
RG CLW | Run 155 - calibration del E | Header: 4alpha source run for delE detector
calibration
Ender:
|
|
172
|
Wed Nov 15 15:41:41 2017 |
RG CLW | Run 157 - EJunk | Header: 4alpha source
Ender:
====================================================
|
|
173
|
Wed Nov 15 16:05:25 2017 |
RG CLW | Run 159 - E detector calibration | Header: 4alpha source run for E det calubration
Ender:
====================================================
|
|
174
|
Wed Nov 15 16:24:35 2017 |
RG CLW | Run 160 - strip numbering E detector | Header: 4alpha source off center (to the top)
Ender:
====================================================
|
|
73
|
Thu Nov 9 17:35:32 2017 |
RG | Run 67 |
Header: 4.7 MeV/u and CH2_30+25.
Ender:
====================================================
Run
number : 67
Date : 09/11
Start time : |
|
34
|
Tue Oct 24 09:27:24 2017 |
Peter Black, DK | Safety words |
Plate 1. Contents of chamber |
|