12
Thu Jul 28 16:00:43 2016
Sarah
List of to-dos
Process alpha data
- Compare pulser width and alpha width
to calibration spectra (shaping amp with
13
Sun Jul 31 13:43:56 2016
Sarah
Alpha spectra
Pulser set to 100 pps.
Shaping amp:
Gain: 1x1.0x50
14
Sun Jul 31 14:32:34 2016
Sarah
DEED1 Alpha calibration checks (205168)
DEED1: (rebin x2 -> 1 bin = 4
ch)
Pulser (DAQ):
15
Sun Jul 31 15:02:57 2016
Sarah
DEED6 Alpha calibration checks (205168)
DEED6: (1 bin = 2 ch)
16
Sun Jul 31 15:56:32 2016
Sarah
DEED16 Alpha calibration checks (205169)
***note that DEED 16 was on old sampling
rate for 205168- so use next run, also DEED
9-12 not plugged in***
17
Tue Aug 2 08:14:26 2016
Sarah
Leakage currents spreadsheet (26/07- 01/08)
Steady for dE, E. Possibly rising
on PHDI- monitor closely.
18
Wed Aug 3 09:48:31 2016
Sarah
EFED10 alpha calibration checks
19
Wed Aug 3 14:48:09 2016
Sarah
Leakage currents 02.08 - 03.08
02.08:
dE = 0.03 uA
E = 0.03 uA
20
Mon Aug 8 11:02:13 2016
Sarah
Leakage currents 08.08.16
E 0.03 uA
dE 0.04 uA
PHDI 0.05 uA
21
Tue Aug 9 15:57:52 2016
Sarah
Leakage currents 09.08.16
Morning - 9am
E= 0.03uA
dE= 0.04uA
22
Thu Aug 11 08:19:37 2016
Sarah
Leakage currents 10.8.16
At lunchtime (12.45)
E = 0.03 uA
dE = 0.04 uA
23
Wed Aug 17 15:10:05 2016
Sarah
Leakage currents 12.08.16
E = 0.03uA
dE = 0.04uA
PHDI = 0.06uA
25
Fri Sep 2 12:01:57 2016
Sarah
Leakage currents 02.09.16
E 0.03
dE 0.05
PHDI 0.12
26
Fri Sep 2 12:03:40 2016
Sarah
SPD card changed
14 bit card replaced for DEED 9-12, to
prevent issue with pulser arriving before
gamma flash.
27
Fri Sep 9 10:01:18 2016
Sarah
Leakage currents 09.09.16
EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA
31
Thu Oct 6 11:07:47 2022
Nikolay Sosnin
Change of sample/Addition of pulser
Changed from LiF 4 to LiF 3 after running
with LiF 4 overnight (run title on n_TOF
DAQ was not updated to refelect the change,
32
Thu Oct 6 11:45:39 2022
Nikolay Sosnin
Assembly Setup Days 1 and 2
Photographs of assembly up to the first
pulser test with LiF3.
25x
33
Thu Oct 6 14:58:29 2022
Nikolay Sosnin
Change of Pulser Delay
Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 1.75 microsecond delay from gamma flash
34
Fri Oct 7 17:17:08 2022
Nikolay Sosnin
Change of Pulser Delay
Still using pulser triggered from protons.
12 microsecond delay from protons to gamma-flash
+ 11 microsecond delay from gamma flash to
35
Fri Oct 7 20:04:30 2022
Nikolay Sosnin
Change of Pulser Setting
The pulser has been switched from triggering
from beam trigger to running at a 10 Hz rate,
and will now appear in random places in signal