AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  AIDA, Page 40 of 44  ELOG logo
Entry  Mon May 4 01:23:48 2015, TD, Unable to obtain Data Acqusition Statistics frame 
Got the error Server Internal Error
while trying to obtain /DataAcquisitionControl/DataAcquisitionStats.tml. 
can't read "cgiNUMdata": no such variable     while executing "InsertLog "cgidata= ([llength $cgidata]) $cgiNUMdata""
    Reply  Mon May 4 02:03:24 2015, TD, Unable to obtain Data Acqusition Statistics frame 


    
        
            Quote:
        
        
            

           Got the error Server Internal Error
Entry  Mon May 4 01:27:56 2015, JA, TD, AE, CG & JLT, Monday 4 May 2015 16x

09.18 SN changed degrader to 5.7mm Al (4mm + all variable degraders + additional 1mm)
Entry  Sun May 3 01:32:18 2015, JA, TD, AE, CG, VP & JLT, Sunday 3 May 2015 

09.19 Beam off on arrival, now back
      R51 running
Entry  Sat May 2 19:20:59 2015, AE, run R51 online spectra ADClow_vs_Ch_R51online.pngADChigh_vs_Ch_R51online.pngX_implant_R51online.pngE_implant_R51online.pngTraking_implant_R51online.png
Online spectra to monitor condition during run R51.

Position and energy spectra indicate implantation in 2nd DSSD. 
Entry  Sat May 2 19:17:25 2015, AE, time-stamp for event reconstruction time_stamp_dist_disc.pngevt_time_stamp_disc_R51.pngXY_implant_disc_R51.pngevt_time_stamp_slowcomp_R51.pngXY_implant_slowcomp_R51.png
Some first analysis of building events to look for implants and decays

Using both DISC and slow comparator values for time-stamp (whatever is available). Clearly there are some ADC
Entry  Sat May 2 14:41:20 2015, JA, TD, AE, CG, VP & JLT, MUSIC detector signals MUSIC_lowE.pngMUSIC_highE_log.png
Adjusted setting of MUSIC detector signals during break
 
MUSIC ---> (16dB att)  --> Lemo split --->  J13
Entry  Sat May 2 02:04:50 2015, JA, TD, AE, CG, VP & JLT, Saturday 2 May 2015 50x
0055: Degrader changed. 1mm removed.
            1.4mm total
0537: R38 ends  nnaida11 slow comparator 0x20 -> 0x40          LEC fast comparator -> 0xff
Entry  Thu Apr 30 15:28:25 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser LYCCA_High_Energy.png
I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards test input. The test capacitor is 30pF.
I was going to explore the effect of the thresholds on the pulser peak.
I notice that the spectra look like those taken in RIKEN and not a single peak. In the 1GeV range I would interpret this as noise but since this
    Reply  Thu Apr 30 17:43:36 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser 
I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards 
test input. The test capacitor is 30pF.
       Reply  Thu Apr 30 20:21:20 2015, Patrick Coleman-Smith, High Energy Spectra from LYCCA with pulser 
> I have an eight FEE64 system now in place on the LYCCA chamber with a PB-5 pulser going into the adapter cards 
> test input. The test capacitor is 30pF.
Entry  Thu Apr 30 16:20:54 2015, JA, LHB, TD, AE, CG & VP, Friday 1 May 2015 
      diode link threshold 0xca -> 0xb6
                           0x11 -> 0x2c 
Entry  Thu Apr 30 03:00:48 2015, TD, Degrader changes 

From 20.00 29.4.15
Entry  Thu Apr 30 02:11:19 2015, TD, Example waveforms with heavy-ion beam 7x

1 - nnaida1 DSSSD#3 p+n (pulser?)
2 - nnaida1 DSSSD#3 p+n heavy ion
Entry  Thu Apr 30 01:06:44 2015, JA, LHB, TD, AE, CG & VP, Thursday 30 April 2015 16x
Overnight
      Degrader OUT
      DAQ ran OK - data file R22
Entry  Wed Apr 29 18:12:02 2015, AE, online analysis code 8x
A first online analysis code is running now in Desktop 4 aidas1

The source code and executable are in 
Entry  Wed Apr 29 11:34:09 2015, Patrick Coleman-Smith, Fast Trigger timings against Pulser Input and LEC/MEC Fast Comparator threshold setting 
I have tried the latest version ( 26 ) of the FEE64 code and carried out some measurements of the Fast Trigger delay from the Pulser signal ( not the
Pulser Trigger out ) and observed the following.
The pulser gives a centroid of 28217 in the histogram.
Entry  Wed Apr 29 11:00:29 2015, TD, Wednesday 29 April 2015 - R20 screenshots 10x
1230: Attachments 

19.00 Screenshots taken during R20
Entry  Wed Apr 29 10:01:27 2015, Patrick Coleman-Smith, Fast Trigger output fault in FEE64 FPGA logic 
 The Fast Trigger output of the FEE64 is formed from the OR of the four OR16 signals ( one from each of the ASICs.
The logic levels of the OR16 signals are active low in the FPGA and so if the are OR'd together then the output is inactive if any one of the ASICs
is inactive.
Entry  Wed Apr 29 01:03:41 2015, JA, LHB, TD, AE, CG & VP, Wednesday 29 April 2015 16x
Overnight
      Beam tuning, PID tests - beam stopped in scintilator detector + 1" thick Pb bricks 
      DAQ ran OK (not to disk)
Entry  Tue Apr 28 11:22:25 2015, VP, RPI 
replace RPI with model B+.  4 USB ports + 4 port switch
 
The RPI system has been replaced by a model B+ which has 4 internal USB ports
Entry  Tue Apr 28 06:25:13 2015, JA, LHB, TD, AE & CG, Tuesday 28th April progress 6x
28/04/15
1420: Carried out ASIC optimisation tests to find best shaping time. Chose system wide shaping time of 0x6.
           Waveforms of example FEEs/channels attachments 1-6.
Entry  Tue Apr 28 05:59:48 2015, AE, "beta" trigger from MACB Trigger outputs 6x
We've constructed a beta trigger with the signals from the p-side of the three DSSDs (OR of all fast
discriminator channels of each FEE).
ELOG V3.1.4-unknown