ID Date Author Subject Text Attachments
  72   Sun Oct 9 15:49:41 2016 JL Tain et alPower shutdownDue to maintenance operations of the Wako
electrical
company there is a risk of power shutdowns
  
  71   Sun Oct 9 04:20:47 2016 JL Tain et alNoiseWe check for the appearance of spurious signals
in the preamplifiers.
 noHV.pdf161008_0642_noHV.pdf 
  70   Sat Oct 8 01:18:51 2016 JL Tain et alDACQWe increased the pretrigger delay for ADC5
from 350 to 400
  
  68   Fri Oct 7 10:42:52 2016 JL Tain et alNoiseWe investigate the effect on the noise in
ORNL tubes of using a differential PA.
 ORNL-DiffPreamp.pdf 
  67   Fri Oct 7 08:35:15 2016 JL Tain et alNoiseLow amplitude noise component.

The figure shows the composition of the low
 noiseDifferentTubes2.pdf 
  66   Fri Oct 7 08:09:47 2016 JLTain et alBackgroundBackground measurement overnight
Start: Oct-6 2242 Stop: Oct-7 10:45
 Bckg-1st.pdf161007_1045_bck.pdf 
  65   Thu Oct 6 14:50:30 2016 JL Tain, A Tolosa, A Tarifeno,...252CfFirst measurement with 252Cf source to check
the calibration.
AIDA was in place so the source was at the
 252Cf-1st.pdf161006_2235_252Cf.pdf 
  64   Thu Oct 6 14:43:47 2016 JL Tain, A Tarifeno, A Tolosa, J Agramunt, N Brewer, S Go, ...ElectronicsWe mount back all preamplifiers
Initially we used all the PA coming from
US, the repaired and the new ones.
  
  63   Thu Oct 6 02:03:32 2016 JL TainSTARTWe started the assembly of BRIKEN and AIDA
detectors in their final position
on Tuesday October 4:
 6x 
  62   Thu Aug 18 23:32:59 2016 NT BrewerNew preamps arrived at Oak Ridge and tested working.Collaborators,

Attached is a phone photo of example
signals from the new preamps with 3 3He tubes
 IMG_20160818_145801.jpgIMG_20160803_160430.jpg 
  Draft   Thu Aug 18 22:39:35 2016 NT BrewerNew preamps arrived at Oak Ridge and tested working.Collaborators,

Attached is a phone photo of example
signals from the new preamps with 3 3He tubes
 IMG_20160818_145801.jpg 
  60   Fri Jul 29 09:52:28 2016 Keishi Matsuiaccuracy of Cf-252's intensity in RIKEN According to the reply from Japan
Radioisotope Association, the accuracy of
the Cf-252's intensity is +0%/-15%.
 IMG_9350.JPG 
  59   Fri Jul 22 12:50:29 2016 J.L. TainEND20/JUL/2016 20:00 
End of the test measurements
  
  58   Wed Jul 20 17:21:59 2016 J. Agramunt, A. TolosaDACQDACQ configuration parameters

The last configuration file used was: 160718Conf_BrikenFull_cal5.xlsx
 160718Conf_BrikenFull_cal5.xlsx 
  57   Wed Jul 20 17:18:59 2016 J.L. Tain, J. Agramunt, A. Tarifeņo, A. Tolosa, K. Gabor, S. Go, K. Matsui...ElectronicsMeasurement with preamplifiers after drying.

Amplifiers are brought back after ~12h and
 Bkg-afterPAdrying.pngV2A4C3-SpuriousSignal.png 
  56   Wed Jul 20 17:05:59 2016 J.L. Tain, J. Agramunt, A. Tarifeņo, A. Tolosa, ...BackgroundBackground measurement with remaining tubes
(95) overnight
 Bkg-with95tubes.png 
  55   Wed Jul 20 16:55:48 2016 K.Gabor, K. Matsui, A. TarifeņoElectronicDrying of preamplifiers

PA8, PA9 and PA10 are removed and brought
  
  54   Wed Jul 20 16:50:12 2016 J.L. Tain, J. Agramunt, A. Tarifeņo, A. Tolosa, S. Go...252CfMeasurement of the 252Cf source at the central
position
  
  53   Wed Jul 20 16:40:57 2016 S. Go, J.Agramunt, A.Tolosa, J.L. Tain,...CLOVERCalibration and resolution check

CLOVER detectors were calibrated in energy
 152Eu.png 
  52   Wed Jul 20 16:12:58 2016 S. Go, ...CLOVERMounting of the CLOVER detectors in position

CLOVER G7: right of beam
 DSC_2522.JPGDSC_2523.JPGDSC_2524.JPG 