  708   Sat May 31 10:46:42 2025 TDRun 38 - remote monitoring
11.40 DAQ continues
      File G22-205/R38

      ASIC settings
       slow comparator 0x32 all FEE64s

      DSSSD bias & leakage current OK - attachments 1-2

      FEE64 temps OK - attachment 3

      ADC data item stats OK - attachment 4

      WR timestamps OK - attachment 5

      per FEE64 Rate spectra - attachment 6

      Merger & Tape Server - attachments 7-8
       filesystem /mnt/data1 4.7Tb remaining

      Online analysis - per DSSSD energy spectra - elastic peak max count / channel c. 250-300Hz - attachment 9

      CRYRING vacuum & temperature - attachments 10-12
       YR09 e-target gauge indicates vacuum transients from high e-11 to low e-9mbar presumably due to high density D2 target

11.42 All histograms & stats zero'd


17.36 DSSSD bias & leakage current OK - attachments 13-14

      FEE64 temps OK - attachment 15

      ADC data item stats OK - attachment 16

      per FEE64 Rate spectra - attachment 17

      per FEE64 1.8.L spectra - attachments 18-19
       aida11 p+n pulser peak width 63 ch FWHM 
       aida03 n+n pulser peak width 85 ch FWHM

      Merger - attachment 20

      Online analysis spectra - elastic peak max count / channel c. few Hz - attachment 21
       rates much lower than earlier - no beam and/or no target - alert JM
Attachment 1: Screenshot_from_2025-05-31_11-40-15.png
Screenshot_from_2025-05-31_11-40-15.png
Attachment 2: Screenshot_from_2025-05-31_11-40-34.png
Screenshot_from_2025-05-31_11-40-34.png
Attachment 3: Screenshot_from_2025-05-31_11-41-01.png
Screenshot_from_2025-05-31_11-41-01.png
Attachment 4: Screenshot_from_2025-05-31_11-41-18.png
Screenshot_from_2025-05-31_11-41-18.png
Attachment 5: Screenshot_from_2025-05-31_11-42-27.png
Screenshot_from_2025-05-31_11-42-27.png
Attachment 6: Screenshot_from_2025-05-31_11-43-50.png
Screenshot_from_2025-05-31_11-43-50.png
Attachment 7: Screenshot_from_2025-05-31_11-44-54.png
Screenshot_from_2025-05-31_11-44-54.png
Attachment 8: Screenshot_from_2025-05-31_11-45-10.png
Screenshot_from_2025-05-31_11-45-10.png
Attachment 9: Screenshot_from_2025-05-31_11-46-08.png
Screenshot_from_2025-05-31_11-46-08.png
Attachment 10: Capture.PNG
Capture.PNG
Attachment 11: Capture_2.PNG
Capture_2.PNG
Attachment 12: Capture_3.PNG
Capture_3.PNG
Attachment 13: Screenshot_from_2025-05-31_17-26-17.png
Screenshot_from_2025-05-31_17-26-17.png
Attachment 14: Screenshot_from_2025-05-31_17-03-49.png
Screenshot_from_2025-05-31_17-03-49.png
Attachment 15: Screenshot_from_2025-05-31_17-03-18.png
Screenshot_from_2025-05-31_17-03-18.png
Attachment 16: Screenshot_from_2025-05-31_17-03-38.png
Screenshot_from_2025-05-31_17-03-38.png
Attachment 17: Screenshot_from_2025-05-31_17-26-42.png
Screenshot_from_2025-05-31_17-26-42.png
Attachment 18: Screenshot_from_2025-05-31_17-27-39.png
Screenshot_from_2025-05-31_17-27-39.png
Attachment 19: Screenshot_from_2025-05-31_17-27-39.png
Screenshot_from_2025-05-31_17-27-39.png
Attachment 20: Screenshot_from_2025-05-31_17-36-49.png
Screenshot_from_2025-05-31_17-36-49.png
Attachment 21: Screenshot_from_2025-05-31_17-37-07.png
Screenshot_from_2025-05-31_17-37-07.png
  593   Thu Jun 6 05:44:45 2024 DR YL DB LB CB JMRun 38 - 15N Tests

06:45

All system checks OK

Target density 3.4e11

11:50

System checks OK.

No beam in the ring yet. Althoug some injection may be taking place at low intensities

Target density appears much more stable than before.

Density currently just above 1e11 at/cm2

Note maintanace is required to appc025 so anydesk is currently down.

 

13:13

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Attachments 1-5 (also waveforms)

 

15:00

Merger OK, Tape server OK

ADC data item statistics DO NOT looks as before. NOT OK

FEE temperatures look OK

System checks OK

Leakage current stable

Attachments 6-8

15:16

Notice the statistics for aida01-aida04 (DDSD 0, top left) were counting extremely high in the previous check (attachment 6). Previous rate was 0-1 counts.

We tried ASIC check load three times but not effect on the rate.

We then tried 'shaking the detectors' by moving the left pneumatic in and out again.

Rates go back to normal levels (0-1 counts)

 

Attachment 1: Screenshot_from_2024-06-06_13-05-55.png
Screenshot_from_2024-06-06_13-05-55.png
Attachment 2: Screenshot_from_2024-06-06_13-06-24.png
Screenshot_from_2024-06-06_13-06-24.png
Attachment 3: Screenshot_from_2024-06-06_13-07-46.png
Screenshot_from_2024-06-06_13-07-46.png
Attachment 4: Screenshot_from_2024-06-06_13-08-40.png
Screenshot_from_2024-06-06_13-08-40.png
Attachment 5: Screenshot_from_2024-06-06_13-09-03.png
Screenshot_from_2024-06-06_13-09-03.png
Attachment 6: Screenshot_from_2024-06-06_14-59-23.png
Screenshot_from_2024-06-06_14-59-23.png
Attachment 7: Screenshot_from_2024-06-06_14-59-34.png
Screenshot_from_2024-06-06_14-59-34.png
Attachment 8: Screenshot_from_2024-06-06_14-59-49.png
Screenshot_from_2024-06-06_14-59-49.png
  707   Sat May 31 09:58:21 2025 JMRun 38

10:56

Run 38 started.

D+ beam deuterium target. D+ beam energy is 1.5 MeV/u. (beam calc calculation is 1.5160 MeV/u)

Beam calc - Attachment 1

Target density is about 8.5e12 at/cm2 after moving nozzle this morning.

All four detectors positioned fully out and stationary.

Left potentiometer = 18.86 mm

Right potentiometer = 19.8 mm

Ring cycle time is 1 minute. Note we see some hydrogen in in the spectrum, this disapears after a few seconds.

Target T1=30K, T2=31.9K.

Nozzle position x=-2.89, z=1.72 mm

YR09-Etarget pressure = 2.37e-10 mbar.

Cooler set value = 846V, 15 mA. Read value = 847.378V, 13.105mA

Detector 4 looks OK at the moment.

Beam position. Vertical =0.0mm , Horizontal=2.5mm

11:05

All checks OK

Data rate is ~300 kB/sec.

Leakage currents - attachments 2,3

17:56

Rates have dropped significantly. Do not see elastics peak. No beam?

18:23

Check in with HKR. The thunder and lightning storm appears to have knocked out the beam from 17:30 until 18:10.

Beam is now back with an intensity of 2e8 pps.

I have also adjusted the nozzle of the gas target slightly and recovered target pressure of 1e13 from 3e11 at/cm2. This has been stable for the last 15 minutes. I think during shifts we will require some nozzle modifications. It is not vital at higher energies but for energies during the week, we will need.

We again see the very nice elastic scattering pattern on our detector. I am concerned we may be some shadowing on our detector giving rise to the observed circle? Attachment 5

20:30

Checks all OK

Target density in last 30 mins ~1e13 at/cm2

DSSD4 still looking good and  stable

23:00

All checks OK.

Detectors all stable

Target density still in 1e13 range.

We have accumulated lots of stats! This run should provide an excellent run for energy calibration using elastics and reaction peaks.

We run overnight and change energy in the morning

01:00

All checks OK

Detectors stable

Target density stable 1e13.

05:00

All good still

07:05

Run stopped to change energy. Gas target off.

final statistics plot attached.

Leakage currents overnight also. DSSD4 had two transients during the night but recovered.

Attachment 1: beamCalc-D2.png
beamCalc-D2.png
Attachment 2: Screenshot_from_2025-05-31_11-07-00.png
Screenshot_from_2025-05-31_11-07-00.png
Attachment 3: Screenshot_from_2025-05-31_11-06-50.png
Screenshot_from_2025-05-31_11-06-50.png
Attachment 4: Screenshot_from_2025-05-31_17-55-33_1.png
Screenshot_from_2025-05-31_17-55-33_1.png
Attachment 5: Screenshot_from_2025-05-31_18-26-29.png
Screenshot_from_2025-05-31_18-26-29.png
Attachment 6: Screenshot_from_2025-05-31_23-04-18.png
Screenshot_from_2025-05-31_23-04-18.png
Attachment 7: Screenshot_from_2025-06-01_07-10-13.png
Screenshot_from_2025-06-01_07-10-13.png
Attachment 8: Screenshot_from_2025-06-01_07-10-21.png
Screenshot_from_2025-06-01_07-10-21.png
Attachment 9: Screenshot_from_2025-06-01_07-10-30.png
Screenshot_from_2025-06-01_07-10-30.png
Attachment 10: Screenshot_from_2025-06-01_07-30-28.png
Screenshot_from_2025-06-01_07-30-28.png
  592   Wed Jun 5 13:34:02 2024 JMRun 37 - Change in thresholds

14:20

Target nozzle currently being replaced. No beam

We have decided to switch to 15N beam from now on.

Beam energy for 15N is significantly higher than deuteron beam so we have increased the thresholds (slow comparator) slightly for all detectors to 500 keV (0x32).

ADC data item rates - attachment 1

Run 37 started. Alpha background

Data rate ~ 200 kb/sec

17:44

All system checks OK

20:00

All system checks OK

23:30

All system checks OK

01:25

All system checks OK

03:25

All system checks OK.

Target is stable at 3.5e11, with T1=29 K

05:30

All system checks OK

Target density has slowly drifted down, and is now 1.2e11

Attachment 1: Screenshot_from_2024-06-05_14-36-44.png
Screenshot_from_2024-06-05_14-36-44.png
  706   Fri May 30 21:49:08 2025 JM, NP, CBRun 37

22:49

Run 37 started.

D+ beam deuterium target. D+ beam energy is 2 MeV/u. (beam calc calculation is 1.9211 MeV/u)

Target density is about 1.3e12 at/cm2. FLuctuations between 1e12 and 1e13 at/cm2.

All four detectors positioned fully out and stationary.

Left potentiometer = 18.86 mm

Right potentiometer = 19.8 mm

Ring cycle time is 1 minute. Note we see some hydrogen in in the spectrum, this disapears after a few seconds.

Target T1=30K, T2=31.9K.

Nozzle position x=-3.11, z=1.77 mm

YR09-Etarget pressure = 1.04e-10 mbar.

Cooler set value = 1126V, 15 mA. Read value = 1068V, 13.22 mA

Detector 4 is still a bit unstable in its leakage current but the data coming through looks good. Some crap is periodically written to disk when leakage current spikes. Attachment 1,2 for leakage currents.

23:30

Checks OK - high but managable rates from DSSD4

01:00

Checks OK - DSSD4 has settled down. Leakage current attachment 1

Ex energy histograms - attachment 2

X2go check on gas target shows density has dropped to 5e11 at/cm2 in last half an hour. 

03:56

Checks OK

DSSD had more issues but once more settled

Temps OK

Rates OK

DAQ continuing

06:00

Checks OK

08:00

We can now change to 1.5 MeV/u no storage mode enabled. 

Attachment 1: Screenshot_from_2025-05-31_00-56-32.png
Screenshot_from_2025-05-31_00-56-32.png
Attachment 2: Screenshot_from_2025-05-31_00-58-40.png
Screenshot_from_2025-05-31_00-58-40.png
Attachment 3: Screenshot_from_2025-05-31_06-16-50.png
Screenshot_from_2025-05-31_06-16-50.png
  591   Wed Jun 5 13:21:45 2024 JM, CBRun 36 - pulser walkthrough

14:00

Access to the cave as Nikos and Andreas have begun work on the target.

Run 36 started - pulser walkthrough.

Pulser amplitudes of 8, 7, 6, 5, 4, 3, 2, 1

Attachment 1 - pn channels

Attachment 2 - nn channels

Attachment 3 - pn channels (zoom)

Attachment 4 - nn channels (zoom)

Best pn channel looks like AIDA09 - pulser width 63

Worst pn channel looks like AIDA14 - pulser width 148

Best nn channel looks like AIDA12 - pulser width 58

Worst nn channel looks like AIDA16 - pulser width 246

This is approximately the same as pulser widths before the beam time.

Attachment 1: Screenshot_from_2024-06-05_14-20-18.png
Screenshot_from_2024-06-05_14-20-18.png
Attachment 2: Screenshot_from_2024-06-05_14-21-26.png
Screenshot_from_2024-06-05_14-21-26.png
Attachment 3: Screenshot_from_2024-06-05_14-27-43.png
Screenshot_from_2024-06-05_14-27-43.png
Attachment 4: Screenshot_from_2024-06-05_14-25-44.png
Screenshot_from_2024-06-05_14-25-44.png
  705   Fri May 30 20:47:47 2025 JM, CB, NPRun 36

21:47

Run 36 started.

D+ beam deuterium target. D+ beam energy is 2 MeV/u.

Target density is about 1.6e12 at/cm2. FLuctuations between 1e12 and 1e13 at/cm2.

Detectors are now IN with the servo motors only. Detectors are stationary.

Left potentiometer = 36.54 mm

Right potentiometer = 37.96 mm

Ring cycle time is 1 minute. Note we see some hydrogen in in the spectrum, this disapears after a few seconds.

Target T1=30K, T2=31.9K.

Nozzle position x=-3.12, z=1.72 mm

YR09-Etarget pressure = 2.29e-10 mbar.

Cooler set value = 1126V, 15 mA. Read value = 1068V, 13.22 mA

Detector 4 is still a bit unstable in its leakage current but the data coming through looks good. Some crap is periodically written to disk when leakage current spikes.

We will run like this for an hour then move detectors back out for overnight run.

after 1 hour of beamtime we stop.

Attachment 1 - xy plot

Attachment 2 - energy histogram NUCLEAR

Attachment 1: Screenshot_from_2025-05-30_22-45-48.png
Screenshot_from_2025-05-30_22-45-48.png
Attachment 2: Screenshot_from_2025-05-30_22-46-48.png
Screenshot_from_2025-05-30_22-46-48.png
  520   Fri Feb 16 22:03:27 2024 TDRun 35 - night shift
22.51 DAQ continues file G22-86/R35_36

      DSSSD bias OK - attachments 1-2

      FEE64 temperatures - attachments 3-4
      CRYRING hall ambient temperature 20
      FEE64 temps tracking ambient temperature - aida01, aida03, aida09 and aida15 - all ( just ) over 65 deg C

      All system wide checks OK

      WR timestamps OK - attachment 5

      ADC, DISC and PAUSE data item stats - attachments 6-8
       hot channels aida01 ( 91k ), aida04 ( 12k ), aida15 ( 11k ) 

      per FEE64 Rate spectra - attachments 9-10
       aida04 & aida13 only FEE64s with significant rates and systematic rate variation with channel #

      per FEE64 1.8.L, 1.8.H and 1.8.W 20us FSR spectra - attachments 11-16

      Merger, Merger stats and TapeServer OK - attachments 17-19

23.16 All histograms, stats and merger stats zero'd

      Online analysis spectra - attachments 21-26
       only the inner quadrants of the 4x DSSSDs are correctly mapped - attachment 21
       observe double peak structure in DSSSD0 rate spectra - radiation damage most forward lab angle strips? - attachment 24

23.23 restart online analysis - zero spectra

23.30 YR12DTIC 2.5e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 4e11/cm2
      See attachments 27-34



01.30 DAQ continues file G22-86/R35_39

      FEE64 temperatures - attachments 35-36

      ADC data item stats - attachment 37

      DSSSD leakage currents - attachment 38

      YR12DTIC 2.5e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 4.1e11/cm2


03.05 YR12DTIC 2.2e7/s
      YR09 vacuum 7e-11 - 1.2e-10 mbar
      density 3.5e11/cm2

      DAQ continues file G22-86/R35_42

      DSSSD leakage currents - attachment 39

      FEE64 temperatures - attachments 40-41

      ADC data item stats - attachment 42

05.05 DAQ continues file G22-86/R35_47

      YR12DTIC 2.5e7/s
      density 3.8e11/cm2

      DAQ continues file G22-86/R35_42

      DSSSD leakage currents - attachment 43

      FEE64 temperatures - attachments 44-45

      ADC data item stats - attachment 46

      per FEE64 Rate spectra - attachments 47-48
       aida12 asic #1 and # 2 HEC activity 
       and following Check ASIC load aida12

      ADC data item stats - attachment 49


Shift Summary

Beam, target density and vacuum appear to have been stable overnight

FEE64 temperatures continue to cycle

Evidence of some radiation damage DSSSDD 0 presumably for most forward lab angle strips?

aida12 asic #1 and #2 high rate HEC activity - fixed by ASIC check load
Attachment 1: Screenshot_from_2024-02-16_22-51-27.png
Screenshot_from_2024-02-16_22-51-27.png
Attachment 2: Screenshot_from_2024-02-16_22-52-15.png
Screenshot_from_2024-02-16_22-52-15.png
Attachment 3: Screenshot_from_2024-02-16_22-53-02.png
Screenshot_from_2024-02-16_22-53-02.png
Attachment 4: Screenshot_from_2024-02-16_22-54-10.png
Screenshot_from_2024-02-16_22-54-10.png
Attachment 5: Screenshot_from_2024-02-16_22-55-11.png
Screenshot_from_2024-02-16_22-55-11.png
Attachment 6: Screenshot_from_2024-02-16_22-55-38.png
Screenshot_from_2024-02-16_22-55-38.png
Attachment 7: Screenshot_from_2024-02-16_22-55-55.png
Screenshot_from_2024-02-16_22-55-55.png
Attachment 8: Screenshot_from_2024-02-16_22-56-24.png
Screenshot_from_2024-02-16_22-56-24.png
Attachment 9: Screenshot_from_2024-02-16_22-57-14.png
Screenshot_from_2024-02-16_22-57-14.png
Attachment 10: Screenshot_from_2024-02-16_22-57-37.png
Screenshot_from_2024-02-16_22-57-37.png
Attachment 11: Screenshot_from_2024-02-16_22-58-23.png
Screenshot_from_2024-02-16_22-58-23.png
Attachment 12: Screenshot_from_2024-02-16_22-59-08.png
Screenshot_from_2024-02-16_22-59-08.png
Attachment 13: Screenshot_from_2024-02-16_22-59-46.png
Screenshot_from_2024-02-16_22-59-46.png
Attachment 14: Screenshot_from_2024-02-16_23-00-33.png
Screenshot_from_2024-02-16_23-00-33.png
Attachment 15: Screenshot_from_2024-02-16_23-01-18.png
Screenshot_from_2024-02-16_23-01-18.png
Attachment 16: Screenshot_from_2024-02-16_23-01-59.png
Screenshot_from_2024-02-16_23-01-59.png
Attachment 17: Screenshot_from_2024-02-16_23-02-21.png
Screenshot_from_2024-02-16_23-02-21.png
Attachment 18: Screenshot_from_2024-02-16_23-02-36.png
Screenshot_from_2024-02-16_23-02-36.png
Attachment 19: Screenshot_from_2024-02-16_23-02-48.png
Screenshot_from_2024-02-16_23-02-48.png
Attachment 20: Capture.PNG
Capture.PNG
Attachment 21: Screenshot_from_2024-02-16_23-18-08.png
Screenshot_from_2024-02-16_23-18-08.png
Attachment 22: Screenshot_from_2024-02-16_23-18-22.png
Screenshot_from_2024-02-16_23-18-22.png
Attachment 23: Screenshot_from_2024-02-16_23-18-34.png
Screenshot_from_2024-02-16_23-18-34.png
Attachment 24: Screenshot_from_2024-02-16_23-19-00.png
Screenshot_from_2024-02-16_23-19-00.png
Attachment 25: Screenshot_from_2024-02-16_23-19-13.png
Screenshot_from_2024-02-16_23-19-13.png
Attachment 26: Screenshot_from_2024-02-16_23-19-26.png
Screenshot_from_2024-02-16_23-19-26.png
Attachment 27: Capture.PNG
Capture.PNG
Attachment 28: 20240216_222850.jpg
20240216_222850.jpg
Attachment 29: 20240216_222907.jpg
20240216_222907.jpg
Attachment 30: 20240216_222736.jpg
20240216_222736.jpg
Attachment 31: 20240216_222950.jpg
20240216_222950.jpg
Attachment 32: 20240216_222747.jpg
20240216_222747.jpg
Attachment 33: 20240216_222928.jpg
20240216_222928.jpg
Attachment 34: 20240216_222941.jpg
20240216_222941.jpg
Attachment 35: Screenshot_from_2024-02-17_01-24-57.png
Screenshot_from_2024-02-17_01-24-57.png
Attachment 36: Screenshot_from_2024-02-17_01-26-57.png
Screenshot_from_2024-02-17_01-26-57.png
Attachment 37: Screenshot_from_2024-02-17_01-27-34.png
Screenshot_from_2024-02-17_01-27-34.png
Attachment 38: Screenshot_from_2024-02-17_01-29-05.png
Screenshot_from_2024-02-17_01-29-05.png
Attachment 39: Screenshot_from_2024-02-17_03-07-38.png
Screenshot_from_2024-02-17_03-07-38.png
Attachment 40: Screenshot_from_2024-02-17_03-08-05.png
Screenshot_from_2024-02-17_03-08-05.png
Attachment 41: Screenshot_from_2024-02-17_03-08-57.png
Screenshot_from_2024-02-17_03-08-57.png
Attachment 42: Screenshot_from_2024-02-17_03-09-26.png
Screenshot_from_2024-02-17_03-09-26.png
Attachment 43: Screenshot_from_2024-02-17_05-06-46.png
Screenshot_from_2024-02-17_05-06-46.png
Attachment 44: Screenshot_from_2024-02-17_05-07-11.png
Screenshot_from_2024-02-17_05-07-11.png
Attachment 45: Screenshot_from_2024-02-17_05-08-19.png
Screenshot_from_2024-02-17_05-08-19.png
Attachment 46: Screenshot_from_2024-02-17_05-09-42.png
Screenshot_from_2024-02-17_05-09-42.png
Attachment 47: Screenshot_from_2024-02-17_05-11-03.png
Screenshot_from_2024-02-17_05-11-03.png
Attachment 48: Screenshot_from_2024-02-17_05-11-27.png
Screenshot_from_2024-02-17_05-11-27.png
Attachment 49: Capture.PNG
Capture.PNG
  519   Fri Feb 16 10:02:41 2024 JM, OF, CB, AR, EMRun 35 - cooled beam on target

11:01

Run 35 started cooled beam on target

Detectors IN (left arm pot =36.5 mm, right arm pot = 70.49 mm)

Electron cooler voltage 751.4 this corresponds to 1.3436 MeV/u. This should be on the peak of the resonance.

Target density is 3.75e11 at/cm2, ring pressure looks OK YR09 1.43e-10 mbar.

Horizontal beam position is -7.5 mm, vertical beam position is 0.0 mm. Same as run 33.

Beam is in the ring for 8 seconds and total cycle time between injections is 12 seconds. Same as run 33

Beam injection looks stable. ~2e7 injected and no missed injections so far.

Merger OK, Tape server OK

Merger statistics zero'd

All histograms and statistics zero'd, monitoring code reset.

ADC data item statistics looks as before, very few counts until injection into the ring. OK

FEE temperatures look OK

System checks OK

Leakage current trending upwards, same as previous elog.

13:33

FEE temperatures OK - all FEEs at least 1.5C below vertex warning

ADC data items statistics OK

Merger and Tape server OK

Target density 3.8e11 at/cm2, ring pressure stable.

Ring injections look very stable

Leakage current now decreasing (attachment 1)

Monitoring code xy and energy histograms (attachment 2+3)

15:03

System wide checks ok. Merger ok. Temperatures ok.

Attatchment 4: Stats

Attatchment 5: Temperatures

Attatchments 6-9: Waveforms.

Attatchment 10: Leakage current

Attatchment 11: lowenergyEytotal plots

17:09

System wide check ok. Merger ok. Temperature ok.

Attachment 12: Stats

Attachment 13: Temperatures

Attachment 14-18: Waveforms (Layout 7: strange behaviour in aida01, went to ASIC Control and did "Check ASIC control" three times, which resolved the problem)

Attachment 19: Leakage current

Attachment 20: lowenergyEytotal plots

Gas pressure was going up a little bit: changed Y position of the nozzle from 1000 to 950.

17:55

The gas jet target pressure started to fall sharply at 17:34 and went down to zero within 2 minutes.

It came back while it we were changing the nozzle position but at 17:49 fell to zero again.

Currently waiting for Nikos to came and have look at it.

18:10

Target back in place and has a density of 4.04e11. Beam transformer looks similar to pre plummeting target density.

 

 

18.55 Check ASIC load FEE64 aida16 asic#3 HEC channels active

 Following check load merger rate decreased significantly.

19:14

Gas density remains stable around 4e11 after the incident at 17:34 and the beam transformer singal looks ok too. Gas pressure ok.

Merger: All aidas turn green but the merger has decreased significantly (too about 306 000 items/sec) as mentioned above.

System wide check ok. Temperature ok.

Attachment 21: Stats

Attachment 22: Temperatures

Attachment 23-26: Waveforms

Attachment 27: Leakage current

 

 

 

 

Attachment 1: Screenshot_from_2024-02-16_13-44-25.png
Screenshot_from_2024-02-16_13-44-25.png
Attachment 2: Screenshot_from_2024-02-16_13-46-26.png
Screenshot_from_2024-02-16_13-46-26.png
Attachment 3: Screenshot_from_2024-02-16_13-46-52.png
Screenshot_from_2024-02-16_13-46-52.png
Attachment 4: Screenshot_from_2024-02-16_14-56-20.png
Screenshot_from_2024-02-16_14-56-20.png
Attachment 5: Screenshot_from_2024-02-16_14-56-38.png
Screenshot_from_2024-02-16_14-56-38.png
Attachment 6: Screenshot_from_2024-02-16_14-58-01.png
Screenshot_from_2024-02-16_14-58-01.png
Attachment 7: Screenshot_from_2024-02-16_14-58-31.png
Screenshot_from_2024-02-16_14-58-31.png
Attachment 8: Screenshot_from_2024-02-16_14-59-59.png
Screenshot_from_2024-02-16_14-59-59.png
Attachment 9: Screenshot_from_2024-02-16_15-00-11.png
Screenshot_from_2024-02-16_15-00-11.png
Attachment 10: Screenshot_from_2024-02-16_15-00-54.png
Screenshot_from_2024-02-16_15-00-54.png
Attachment 11: Screenshot_from_2024-02-16_15-02-24.png
Screenshot_from_2024-02-16_15-02-24.png
Attachment 12: Screenshot_from_2024-02-16_16-54-55.png
Screenshot_from_2024-02-16_16-54-55.png
Attachment 13: Screenshot_from_2024-02-16_16-55-17.png
Screenshot_from_2024-02-16_16-55-17.png
Attachment 14: Screenshot_from_2024-02-16_16-56-23.png
Screenshot_from_2024-02-16_16-56-23.png
Attachment 15: Screenshot_from_2024-02-16_16-57-08.png
Screenshot_from_2024-02-16_16-57-08.png
Attachment 16: Screenshot_from_2024-02-16_16-58-01.png
Screenshot_from_2024-02-16_16-58-01.png
Attachment 17: Screenshot_from_2024-02-16_17-04-41.png
Screenshot_from_2024-02-16_17-04-41.png
Attachment 18: Screenshot_from_2024-02-16_17-06-07.png
Screenshot_from_2024-02-16_17-06-07.png
Attachment 19: Screenshot_from_2024-02-16_17-08-45.png
Screenshot_from_2024-02-16_17-08-45.png
Attachment 20: Screenshot_from_2024-02-16_17-20-51.png
Screenshot_from_2024-02-16_17-20-51.png
Attachment 21: Screenshot_from_2024-02-16_19-10-26.png
Screenshot_from_2024-02-16_19-10-26.png
Attachment 22: Screenshot_from_2024-02-16_19-10-39.png
Screenshot_from_2024-02-16_19-10-39.png
Attachment 23: Screenshot_from_2024-02-16_19-11-56.png
Screenshot_from_2024-02-16_19-11-56.png
Attachment 24: Screenshot_from_2024-02-16_19-12-21.png
Screenshot_from_2024-02-16_19-12-21.png
Attachment 25: Screenshot_from_2024-02-16_19-12-50.png
Screenshot_from_2024-02-16_19-12-50.png
Attachment 26: Screenshot_from_2024-02-16_19-13-32.png
Screenshot_from_2024-02-16_19-13-32.png
Attachment 27: Screenshot_from_2024-02-16_19-14-12.png
Screenshot_from_2024-02-16_19-14-12.png
  521   Sat Feb 17 06:19:27 2024 JM, CBRun 35 - contd

07:10

FEE temperatures OK

System checks OK
Merger and tape server OK
Statistics look OK,
Rates in the detectors from the mointoring code indicate we have beam on target.

Detector leakge current appears to be following same pattern as yesterday -> temperature (attachment 1)

Merger stats (attachment 2) - quite a few more pause / resume statements than normal - noise last night?

Target density appears stable over the last 3 hours ~3.8e11 at/cm2, ring pressure stable YR09 ~1.5e-10 mbar

Beam injection looks stable over the last few hours.

09:08

FEE temperatures OK -aida03 and aida09 0.5 C over 65C warning.

system checks OK

ADC data item stats  OK

Spectrum browser rate (attachment 3)

Merger and Tape server OK

Monitoring  xy and energy histograms since zero'd last night (attachments 4+5)

Target density slight drop to ~3.5e11 at/cm2. Pressure in the ring stable. CB attempting to optimise target density and ring pressure.

Beam injection into the ring still good

11:04

FEE temperatures OK

System checks OK

ADC data items and spectrum browser rates OK

Target density ~4.6e11 at/cm2, ring pressure looks OK ~1e-10 mbar

Beam injection still good.

Merger and tape server OK

12:45

Beam injection over last 2 hours has been stable

Target density 4.75e11 and stable. ring pressures are stable.

FEE temperatures OK

System checks OK

ADC data items stats and spectrum browser rates look OK

Merger and tape server OK

14:01

We wish to test the beam ahlo on injection so are ending run

Run stopped.

Attachment 1: Screenshot_from_2024-02-17_07-20-01.png
Screenshot_from_2024-02-17_07-20-01.png
Attachment 2: Screenshot_from_2024-02-17_07-21-27.png
Screenshot_from_2024-02-17_07-21-27.png
Attachment 3: Screenshot_from_2024-02-17_09-09-35.png
Screenshot_from_2024-02-17_09-09-35.png
Attachment 4: Screenshot_from_2024-02-17_09-13-44.png
Screenshot_from_2024-02-17_09-13-44.png
Attachment 5: Screenshot_from_2024-02-17_09-14-35.png
Screenshot_from_2024-02-17_09-14-35.png
  588   Tue Jun 4 18:08:04 2024 Boudefla Dounia - CB - LB - SDRun 34

19:08

Beam energy = 3 MeV.

Horizontal beam position = 4.0 mm, vertical beam position = 0.0 mm.

Target density ~ fluctuating

Beam intensity at inj ~ 1.7e7

Detectors are positioned IN. Left arm = 36.54, right arm =  64.60 mm

MBS signals saved from motors code

Histograms and stats zero'd, monitoring code restarted.

Beam in the ring ~ 6 minutes.

Pressure in YR09 E target ~ 4.36e-11 mbar.

 

 

Merger error recovered

White rabbit time stamps

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

21:27

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

23:00

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Statistics attachment 5

Merger attachment 6

 

00:42

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Density is oscillating between E10 and low E11.

attachment 7 is statistics, attachment 8 is temperature, attachment 9 is merger, attachment 10 is spectrum browser.

 

02:20

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Density is oscillating between E10 and low E11. ( last 15 minutes below 2E10)

attachment 11 -13

 

From 2:00 target density falls below 2E10 and started decreasing to the E9 range. At 2:40 we started playing with x-y to get to higher density. At 3:30 we are at 5/6E10 and waiting to see if it stabilizesto that or if it needs more playing.

04:06

Target density being 1-2E11 since 5 minutes

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Attachment 14 statistics, attachment 15 merger

 

05;53

Target density 1E10, sometimes e11, before going down to low E10 and we need to play a bit with x-y to recover it

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Attachment 16-18

 

07:35

Target density 2.5E11, after changiny y position to 1000

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

09:00

Target density has not improved despite efforts last night. Mid 10 - low 11 density range. We have asked HKR to remove beam from the ring and allow access so Nikos can change the nozzle.

Beam off now, access granted. Will begin warming nozzle. Internal cave work on changing nozzle expected to start at 11

Run stopped.

Final monitoring code histogram attached

 

Attachment 1: Screenshot_from_2024-06-04_19-07-40.png
Screenshot_from_2024-06-04_19-07-40.png
Attachment 2: Screenshot_from_2024-06-04_19-11-14.png
Screenshot_from_2024-06-04_19-11-14.png
Attachment 3: Screenshot_from_2024-06-04_21-26-45.png
Screenshot_from_2024-06-04_21-26-45.png
Attachment 4: Screenshot_from_2024-06-04_21-26-50.png
Screenshot_from_2024-06-04_21-26-50.png
Attachment 5: Screenshot_from_2024-06-04_22-40-39.png
Screenshot_from_2024-06-04_22-40-39.png
Attachment 6: Screenshot_from_2024-06-04_22-43-21.png
Screenshot_from_2024-06-04_22-43-21.png
Attachment 7: Screenshot_from_2024-06-05_00-44-49.png
Screenshot_from_2024-06-05_00-44-49.png
Attachment 8: Screenshot_from_2024-06-05_00-45-21.png
Screenshot_from_2024-06-05_00-45-21.png
Attachment 9: Screenshot_from_2024-06-05_00-45-41.png
Screenshot_from_2024-06-05_00-45-41.png
Attachment 10: Screenshot_from_2024-06-05_00-47-33.png
Screenshot_from_2024-06-05_00-47-33.png
Attachment 11: Screenshot_from_2024-06-05_02-21-37.png
Screenshot_from_2024-06-05_02-21-37.png
Attachment 12: Screenshot_from_2024-06-05_02-22-15.png
Screenshot_from_2024-06-05_02-22-15.png
Attachment 13: Screenshot_from_2024-06-05_02-22-44.png
Screenshot_from_2024-06-05_02-22-44.png
Attachment 14: Screenshot_from_2024-06-05_04-06-59.png
Screenshot_from_2024-06-05_04-06-59.png
Attachment 15: Screenshot_from_2024-06-05_04-07-43.png
Screenshot_from_2024-06-05_04-07-43.png
Attachment 16: Screenshot_from_2024-06-05_05-55-15.png
Screenshot_from_2024-06-05_05-55-15.png
Attachment 17: Screenshot_from_2024-06-05_05-55-49.png
Screenshot_from_2024-06-05_05-55-49.png
Attachment 18: Screenshot_from_2024-06-05_05-56-34.png
Screenshot_from_2024-06-05_05-56-34.png
Attachment 19: Screenshot_from_2024-06-05_09-04-45.png
Screenshot_from_2024-06-05_09-04-45.png
  587   Tue Jun 4 15:25:36 2024 BD US CBRun 33

16:26

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Nicos came in to optimize target density.

 

18:39

aida02 in the MERGER aka aida03 elsewhere has a red background, but still appears to be transferring data. Rates are fine. Temps are fine. System wide checks unchanged.

See attachments. Checkloaded x2 - no difference. Unclear what the issue is.

Attachment 1: Screenshot_from_2024-06-04_18-33-23.png
Screenshot_from_2024-06-04_18-33-23.png
Attachment 2: Screenshot_from_2024-06-04_18-33-38.png
Screenshot_from_2024-06-04_18-33-38.png
Attachment 3: Screenshot_from_2024-06-04_18-35-26.png
Screenshot_from_2024-06-04_18-35-26.png
Attachment 4: Screenshot_from_2024-06-04_18-36-55.png
Screenshot_from_2024-06-04_18-36-55.png
  586   Tue Jun 4 14:13:17 2024 JM, CB, DB, USRun 32- beam only background

15:15

Run 32 started - Beam, no target

Beam energy = 3 MeV.

Horizontal beam position = 4.0 mm, vertical beam position = 0.0 mm.

Beam intensity at inj ~ 2.5e7

Detectors are positioned IN. Left arm = 36.54, right arm =  64.60 mm

Histograms and stats zero'd, monitoring code restarted.

Beam in the ring ~ 5 minutes.

Pressure in YR09 E target ~ 4.5e-11 mbar.

Motors code crashed. Beam removed from ring to re-home detectors.

 

15:20

Beam in the ring again, detectors homed, no target

Detectors have been set up to send signals on injection / dump

15:35

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

  702   Thu May 29 18:04:47 2025 LB, CB, PMH, JMRun 32,33,34

Oven temperature increased, current up to 3.5E7 pps.

Found beam-target overlap setting horizontal bump in RO9 to -2.5mm.

Target T1 30.5K, density increasing to 2.6E11 at/cm2.

19:08 Run 32 start

Moving left detectors (79.69->34.66mm).

Beam energy 1.85 MeV/u nominal

Electron cooler actual values: voltage 1.051 kV,  current 0.013215 uA, [voltage divider G35 1.0504 kV]

Stopped run, beam was still in bunch mode.

19:15 Run 33 start

All checks Ok.

Target at 3E11 at/cm2

Attachment 1-2 with rates and temperatures

 

20:20

Target density 3.4E11 at/cm2. Beam around 2.2-3.6E7 pps.

Checks ok! Spectra attached in att.3.

21:25

all good. Target density 4E11 at/cm^2

22:24

All checks are OK

Noted some variability in the injection intensity. For 15 minutes about half of shots were below 1e7. Perhaps some variability due to end of lithium in oven or increased temperture. 

Beam calc with read values - Attachment 4

01:30

All checks OK. Injection intensity has stabilised ~2E7

Target density is stable ~4e11 at/cm2

02:44

Suddenly see very high rates in DSSD4. Detector had tripped. Tried to re-bias but kept tripping.

Set to 70V, leakage current is about 17uA but fluctuates quite wildly. Set to 50V and leakage current is about 6uA but again has wild fluctuations. Not sure of the cause, this detector is not moving and is far from the beam.

Decided to turn detector off to try and protect it. We can  re-bias and monitor in the day tomorrow when we do not have beam on target.

This detector has tripped previously but was able to be re-biased at the time. See attachments 5 and 6 for the detector leakage currents.

New Run started R34.

Same conditions as before. DSSD4 turned off. To stop crap writing to disk I have set the corresponding FEEs to the MEC.

In principle we do not need this detector now as it is not moving to see the reaction.

Note I also observed in the system messages we semi regularly get a DHCP request from aida11. It seems to be functioning fine as I see the pulser signal in the spectrum browser. May be worth following up on at a later date. See attachment 7

All other checks OK

Data rate is now ~140 kB/sec

03:15

Tried to bias DSSD4 again. Leakage currents appear fine again.

Left for 5 minutes to gauge stability -> seems fine.

03:22

Have returned aida13, 14, 15, 16 back to LEC.  Maintaing the same run (34)

Scratch that. 03:27 detector tripped again. Will just leave it off tonight. Turned those FEEs back to MEC.

06:00

I have quickly looked at Run 33. We clearly see the 7Be again in both detectors. Locus on detector much smaller than at higher energies. 

All checks OK

07:07

Run stopped, switching to deuterium.

Detectors moved out

Shutter for gas target off.

Moved to next run -> no storage mode.

Attachment 1: Screenshot_from_2025-05-29_19-16-09.png
Screenshot_from_2025-05-29_19-16-09.png
Attachment 2: Screenshot_from_2025-05-29_19-12-46.png
Screenshot_from_2025-05-29_19-12-46.png
Attachment 3: Screenshot_from_2025-05-29_20-23-50.png
Screenshot_from_2025-05-29_20-23-50.png
Attachment 4: beamCalc.png
beamCalc.png
Attachment 5: Screenshot_from_2025-05-30_02-37-55.png
Screenshot_from_2025-05-30_02-37-55.png
Attachment 6: Screenshot_from_2025-05-30_02-51-21.png
Screenshot_from_2025-05-30_02-51-21.png
Attachment 7: Screenshot_from_2025-05-30_02-38-10.png
Screenshot_from_2025-05-30_02-38-10.png
  585   Tue Jun 4 06:56:02 2024 DFF, PC, LB, JM,NP,ABRun 31 contd

8:13

Since 6:40 the target density dramatically dropped to 10^9 since then it has been unstable and did not recover. Currently it is around 8e8.

09:00

Target density has been increased to the high -10, very low -11 region. We will keep this run going unless the density is increased further.

 

10:21

Beam energy = 3 MeV.

Horizontal beam position = 4.0 mm, vertical beam position = 0.0 mm.

Target density ~ 1e9 at/cm2 (no target, get lost quite quckly)

Beam intensity at inj ~ 1.7e7

Detectors are positioned IN. Left arm = 36.54, right arm =  64.60 mm

Histograms and stats zero'd, monitoring code restarted.

Beam in the ring ~ 6 minutes.

Pressure in YR09 E target ~ 4.36e-11 mbar.

 

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

target density has been fluctuating between E9 to E12. We can very clearly see the increase in elastic counts on our detector during high density periods.

Attachment 1 - rate plots at 1E12 at/cm2

Attachment 2 - rate plots at 1E9 at/cm2

 

12:26

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

After reaching a density of > 10^12 a bit before 11:00, the valve got closed. When a valve is closed, can be observed a dramatic change in the plot and one of the three green ligths of atps7vaccrz1 (0,2,4) is turned off. Nikos opened it, and now it seems stable again around 1e11.

 

14:07

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

15:05

Run stopped as target density is rubbish. Might as well get beam background

Attachment 1: Screenshot_from_2024-06-04_10-53-58.png
Screenshot_from_2024-06-04_10-53-58.png
Attachment 2: Screenshot_from_2024-06-04_10-58-02.png
Screenshot_from_2024-06-04_10-58-02.png
  584   Tue Jun 4 00:04:39 2024 DR, EHRun 31

Beam energy = 3 MeV

Horizontal beam position = 4.0 mm, vertical beam position = 0.0 mm.

Beam intensity at inj ~ 2.5e7

Detectors are positioned IN. Left arm = 36.54, right arm =  64.60 mm

Cycle time ~ 6 minutes

 

01:05

Target density still very unstable

 

02:45

Target density has dropped to ~1e9 and has been at that level for 30 minutes. We will try to move the target a bit and see if we can get an increase. Target position is currently x=-12400, y=2900

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

 

04:15

We were able to recover some target, but it is still very unstable. The new position is x=-12800, y=2000

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

 

06:15

Target still unstable, fluctuating around the 5e10 region

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

  701   Thu May 29 14:39:52 2025 CB LB PMHRun 31

15:40

Waiting for Serge to come in to change beam energy.

Remaining at the same beam energy and settings as before, except RIGHT arm now moving.

Run 31

37.96 -> 83.69 mm

 

16:53

Serge arrived. Run ended. Motors out. No storage.

Temps OK

Rates OK

 

 

Attachment 1: Screenshot_from_2025-05-29_15-41-46.png
Screenshot_from_2025-05-29_15-41-46.png
Attachment 2: Screenshot_from_2025-05-29_15-42-11.png
Screenshot_from_2025-05-29_15-42-11.png
Attachment 3: Screenshot_from_2025-05-29_15-42-49.png
Screenshot_from_2025-05-29_15-42-49.png
Attachment 4: Screenshot_from_2025-05-29_16-58-12.png
Screenshot_from_2025-05-29_16-58-12.png
Attachment 5: Screenshot_from_2025-05-29_16-58-16.png
Screenshot_from_2025-05-29_16-58-16.png
Attachment 6: Screenshot_from_2025-05-29_16-58-18.png
Screenshot_from_2025-05-29_16-58-18.png
Attachment 7: Screenshot_from_2025-05-29_16-58-21.png
Screenshot_from_2025-05-29_16-58-21.png
Attachment 8: Screenshot_from_2025-05-29_16-58-23.png
Screenshot_from_2025-05-29_16-58-23.png
Attachment 9: Screenshot_from_2025-05-29_16-58-26.png
Screenshot_from_2025-05-29_16-58-26.png
  700   Wed May 28 16:40:48 2025 EH, SN, LB, OF, EBM, CBRun 28/29/30 - 1.88 MeV/A

We start a new run with real data taking condititon: beam is ok, target density is 1e12 cm-2, detectors are moving in-out periodically.

 

Cooler voltage setpoint 1066.6 V. Read value 1068 V.

Current read = 0.01325 uA

Beam energy = 1.88 MeV/u (from HKR)

Attachment 1 - beamcalc with nominal values

Attachment 32 - beamcalc with actual values

 

Right arm at 19.80 mm

Left  arm IN at 77.56 mm (OUT 32.77 mm)

vertical beam position 0.0 mm

horizontal beam position  -3.0mm

Beam intensity ~1.8e+7 particles.

Target density ~1e12 at/cm2

Target temperatures: T1=31.4 K T2=35.1 K

 

17:48

aida01 fault      0x0 :      0x1 :      1  
FPGA Timestamp error counter test result: Passed 15, Failed 1

All checks OK.

The electron current from beamcalc is the setvalue.

 

18:51

aida01 fault      0x0 :      0x1 :      1  
FPGA Timestamp error counter test result: Passed 15, Failed 1

All checks OK.

20:20

aida01 fault      0x0 :      0x1 :      1  
FPGA Timestamp error counter test result: Passed 15, Failed 1

All checks OK.

22:02

         Base         Current         Difference
aida01 fault      0x0 :      0x1 :      1  
FPGA Timestamp error counter test result: Passed 15, Failed 1

All checks OK.

 

23:13

All checks OK. Target stabilized at ~6.7E11 at/cm^2

00:23

All checks good.

01:01

We are observing what seems to be a steady decrease of the target density, currently at around 5e11 at/cm2, whihc also seems to be following a decrease in the temperature T2.

1;40

All checks good. Spectra attached in att. 18. Target density still decreasing (3.7E11 at/vcm2)2

2:54

All checks ok. Attached rates and spectra in att. 19-20. target density decreased as continued, now around 2.5E11 at/cm^2.

We tried to move a bit around the nozzle/target, no effect.

Gone back to original value of x=1000, y=-4200.

Moreover, the screen with the program to move the detector seems to be bugged (gray background, a double window): however, the potentiometer value is chnaging and I see the usual effect of detector moving on the statistics, so i think it is fine

3:38

Checks Ok. Target 2.5E11 at/cm2

4:05

The bug disappeared

4:56

Target density is now 1.9E11 at/cm2. It is very low with respect to before, but our reasoning is that nothing can be done about it at night anyway (apart from moving the nozzle, which we tried without effect). O. pointed out that the beam lifetime is still such that the beam is gone before the next injection.

Checks ok. Attachments 21-22 spectra and xy plot. Some structure in top left?

06:00

All check ok. Target density 1.8E11 at/cm2

6:49

all goo, target 1.7E11 at/cm2

07:30

All checks ok, except timestamp (15 passed, 1 failed, see screenshot)

8:30

Tried moving the nozzle. Minor improvement in target density only. x=-1000 y=-4200

Stopped writing to disk while moving nozzle and stopped the motors. Restarted everything and moved to run 29 - no differences vs. 28.

09:11

Temps OK.

Nautilus does not respond to user commands. Attempint to make it work again without rebooting.

10:05

Stopped to reconsider which arm we are moving. Started to move arms around. Decided to stick with left arm.

Started run 30. Same as 28 and 29.

 

10:30

Temps OK - attach

Rates OK - attach

Stats OK (taken with arm in) - attach

Current histogram attached

 

11:40

Something happened to leakage currents. We see an increase in the top-right detector (which recovered) and a decrease in the bottom-right. Neither is moving.

No changes to left arm detectors, which are moving.

Temperature in the cave stable. No effects on the DAQ.

Temps OK

Rates in aida06 at 10k. Fast discriminator at 100k. Checkloaded. OK. Other rates fine.

Will keep monitoring.

 

11:50

aida06 fast discriminator over 100k. Checkloaded x2. OK now. Other rates fine.

No changes to leakage current.

 

13:20

Temps OK

Rates OK (aida 06 is no longer counting fast)

Leakage current stable

 

14:20

Run continues OK

Temps OK

Stats OK


Attachment 1: Screenshot_2025-05-28_17-51-17.png
Screenshot_2025-05-28_17-51-17.png
Attachment 2: Screenshot_from_2025-05-28_17-47-21.png
Screenshot_from_2025-05-28_17-47-21.png
Attachment 3: Screenshot_from_2025-05-28_17-49-00.png
Screenshot_from_2025-05-28_17-49-00.png
Attachment 4: Screenshot_from_2025-05-28_17-49-11.png
Screenshot_from_2025-05-28_17-49-11.png
Attachment 5: Screenshot_from_2025-05-28_17-49-30.png
Screenshot_from_2025-05-28_17-49-30.png
Attachment 6: Screenshot_from_2025-05-28_17-49-41.png
Screenshot_from_2025-05-28_17-49-41.png
Attachment 7: Screenshot_from_2025-05-28_18-52-35.png
Screenshot_from_2025-05-28_18-52-35.png
Attachment 8: Screenshot_from_2025-05-28_18-52-46.png
Screenshot_from_2025-05-28_18-52-46.png
Attachment 9: Screenshot_from_2025-05-28_18-52-56.png
Screenshot_from_2025-05-28_18-52-56.png
Attachment 10: Screenshot_from_2025-05-28_18-53-04.png
Screenshot_from_2025-05-28_18-53-04.png
Attachment 11: Screenshot_from_2025-05-28_18-53-34.png
Screenshot_from_2025-05-28_18-53-34.png
Attachment 12: Screenshot_from_2025-05-28_20-21-22.png
Screenshot_from_2025-05-28_20-21-22.png
Attachment 13: Screenshot_from_2025-05-28_22-04-57.png
Screenshot_from_2025-05-28_22-04-57.png
Attachment 14: Screenshot_from_2025-05-28_22-04-40.png
Screenshot_from_2025-05-28_22-04-40.png
Attachment 15: Screenshot_from_2025-05-28_22-04-26.png
Screenshot_from_2025-05-28_22-04-26.png
Attachment 16: Screenshot_from_2025-05-28_22-04-36.png
Screenshot_from_2025-05-28_22-04-36.png
Attachment 17: Screenshot_from_2025-05-28_22-04-52.png
Screenshot_from_2025-05-28_22-04-52.png
Attachment 18: Screenshot_from_2025-05-29_01-43-22.png
Screenshot_from_2025-05-29_01-43-22.png
Attachment 19: Screenshot_from_2025-05-29_02-53-41.png
Screenshot_from_2025-05-29_02-53-41.png
Attachment 20: Screenshot_from_2025-05-29_02-54-03.png
Screenshot_from_2025-05-29_02-54-03.png
Attachment 21: Screenshot_from_2025-05-29_05-00-39.png
Screenshot_from_2025-05-29_05-00-39.png
Attachment 22: Screenshot_from_2025-05-29_05-00-13.png
Screenshot_from_2025-05-29_05-00-13.png
Attachment 23: Screenshot_from_2025-05-29_07-31-25.png
Screenshot_from_2025-05-29_07-31-25.png
Attachment 24: Screenshot_from_2025-05-29_07-30-25.png
Screenshot_from_2025-05-29_07-30-25.png
Attachment 25: Screenshot_from_2025-05-29_07-30-10.png
Screenshot_from_2025-05-29_07-30-10.png
Attachment 26: Screenshot_from_2025-05-29_07-29-42.png
Screenshot_from_2025-05-29_07-29-42.png
Attachment 27: Screenshot_from_2025-05-29_08-41-51.png
Screenshot_from_2025-05-29_08-41-51.png
Attachment 28: Screenshot_from_2025-05-29_10-30-00.png
Screenshot_from_2025-05-29_10-30-00.png
Attachment 29: Screenshot_from_2025-05-29_10-30-03.png
Screenshot_from_2025-05-29_10-30-03.png
Attachment 30: Screenshot_from_2025-05-29_10-30-16.png
Screenshot_from_2025-05-29_10-30-16.png
Attachment 31: Screenshot_from_2025-05-29_10-30-19.png
Screenshot_from_2025-05-29_10-30-19.png
Attachment 32: screenshot-2025-05-29_11-13-385986126969656182153.png
screenshot-2025-05-29_11-13-385986126969656182153.png
Attachment 33: Screenshot_from_2025-05-29_11-38-07.png
Screenshot_from_2025-05-29_11-38-07.png
Attachment 34: Screenshot_from_2025-05-29_11-38-10.png
Screenshot_from_2025-05-29_11-38-10.png
Attachment 35: Screenshot_from_2025-05-29_11-44-55.png
Screenshot_from_2025-05-29_11-44-55.png
Attachment 36: Screenshot_from_2025-05-29_11-44-55.png
Screenshot_from_2025-05-29_11-44-55.png
Attachment 37: Screenshot_from_2025-05-29_14-19-52.png
Screenshot_from_2025-05-29_14-19-52.png
  513   Wed Feb 14 14:59:13 2024 JM, CB, NP, ML, AG, ABRun 27 -Beam on target optimisation

Run 27 Started to check optimsation of the beam - target overlap.

Beam intensity at injection is roughly 1e7 particles

Target density apporx 4.2e11 atoms/cm2 and stable.

Ring pressure is below 1e-10 mbar for all ring sections and stable

First optimisation procedure was to vary the horizontal beam position and see the effect on the count rate in detector #0 (top left) (see elog 509). Beam position was scanned from -9 and -4. Attachment 1 shows the maximum in count rate around the -7.5 position. 

Second optimisation procedure was to change the time ions are allowed to circulate in the ring before being dumped. The count rate over 5 minutes in detector #0 (top left) at ~20 MeV was used as a gauge. This is the only part of the cycle we can control.

Time (s)    Counts

2               148

3               200

4               178

Attachment 1: Target-overlap-scan-optimized.pdf
Target-overlap-scan-optimized.pdf Target-overlap-scan-optimized.pdf Target-overlap-scan-optimized.pdf
  580   Mon Jun 3 11:46:07 2024 SD, SHB, JM, CN, EMRun 27

12:46 (attachments 1-4)

Run 27 started - Beam no target

Beam energy = 3 MeV

Horizontal beam position = 7.0 mm, vertical beam position = 0.0 mm.

Beam intensity at inj ~ 2.5e7

Detectors are positioned IN pneumatic only. Left arm = 62.71, right arm =  64.60 mm

Histograms and stats zero'd, monitoring code restarted.

Beam in the ring ~ 7 minutes.

Beam on BPM looks to be better than at previous energy.

Pressure in YR09 E target ~ 4.5e-11 mbar.

 

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

13:45 (attachments 5-8)

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

 

 

15:15(attachments 9-12)

Merger OK, Tape server OK

ADC data item statistics looks as before. OK

FEE temperatures look OK

System checks OK

Leakage current stable

Target density 1e10 atoms/cm2. Still working on the target.

 

 

Attachment 1: Screenshot_from_2024-06-03_12-48-03.png
Screenshot_from_2024-06-03_12-48-03.png
Attachment 2: Screenshot_from_2024-06-03_12-48-37.png
Screenshot_from_2024-06-03_12-48-37.png
Attachment 3: Screenshot_from_2024-06-03_12-49-13.png
Screenshot_from_2024-06-03_12-49-13.png
Attachment 4: Screenshot_from_2024-06-03_12-49-47.png
Screenshot_from_2024-06-03_12-49-47.png
Attachment 5: Screenshot_from_2024-06-03_13-45-42.png
Screenshot_from_2024-06-03_13-45-42.png
Attachment 6: Screenshot_from_2024-06-03_13-46-49.png
Screenshot_from_2024-06-03_13-46-49.png
Attachment 7: Screenshot_from_2024-06-03_13-47-32.png
Screenshot_from_2024-06-03_13-47-32.png
Attachment 8: Screenshot_from_2024-06-03_13-47-51.png
Screenshot_from_2024-06-03_13-47-51.png
Attachment 9: Screenshot_from_2024-06-03_15-16-51.png
Screenshot_from_2024-06-03_15-16-51.png
Attachment 10: Screenshot_from_2024-06-03_15-17-49.png
Screenshot_from_2024-06-03_15-17-49.png
Attachment 11: Screenshot_from_2024-06-03_15-18-19.png
Screenshot_from_2024-06-03_15-18-19.png
Attachment 12: Screenshot_from_2024-06-03_15-22-14.png
Screenshot_from_2024-06-03_15-22-14.png
ELOG V3.1.4-unknown