Entry  Thu Aug 31 08:36:34 2023, CB, NEG activation  
Found CARME at 50C, a bit cooler than expected, probably due to invasive tent changes yesterday to mount missing wires. Increased heaters temperature
to 300C

 
Entry  Wed Feb 23 09:50:19 2022, Laszlo, Thanassis, Moving detector in 
We are moving the detector in run 56
Entry  Wed Feb 14 08:44:32 2024, CB AR JM, Motors test and turbo ON 11x
Run number changed 09:44 - Now run 23

Moving motors with the injection

Ring signal very weird, moving in for short time and staying out for 15+ seconds.
Entry  Fri Oct 8 17:56:35 2021, CB RSS, Motors test 20211008_184731.jpg20211008_184731.jpg
Attempted first motor test in XHV. Wired and connected limit switches and string potentiometer.

Set up raspberry pi to control motors (.124). Set up pi for remote headless access.

Moved jumper on Teknic hub from 1 to 2 motors configuration.
Entry  Tue Oct 12 09:22:37 2021, RSS TD + OG DR, Motors problem solved IMG_4971.JPGIMG_4970.JPG
Neg and ion cables were taken off and were put in the box.

Top support was taken off.

Motors are rotating again. Have to be careful with the position of the limit switches.
Entry  Mon Sep 6 14:13:17 2021, CB ML, Motors mounted - first attempt 20210906_113522.jpg20210906_113519.jpg20210906_115601.jpg20210906_152607.jpg20210906_143944.jpg
Mounted both  motors on CARME. Started 
with outside motor.
Entry  Sun Jun 25 14:30:06 2023, JM, TD, Motors bias test 
The motors were moved using the pneumatic only, in and out for several cycles to gauge the effect on the vacuum. For the left arm no change in pressure
was observed. For the right arm a small increase of 0.04e-7 mbar was observed which was quickly reduced by the turbo. 

The detectors were then biased to see if movement had any effect on the leakage current (large effects were observed in 2021 beamtime). Movement
Entry  Sat Sep 4 15:54:50 2021, CB RSS, Motor mounting preparation 20210904_162517.jpg20210904_162520.jpg
Prepared the motors to be mounted and 
found all components required. No issues. 
May have to partly dismount again to fix 
Entry  Wed Feb 7 10:09:14 2024, CB, JG, EM, Morning Shift  Screenshot_from_2024-02-07_11-10-08.pngScreenshot_from_2024-02-07_11-10-59.pngScreenshot_from_2024-02-07_11-15-53.pngScreenshot_from_2024-02-07_11-20-38.png
11:00

Changed slow comp threshold to 0x32 (500 keV). Checkloaded.

 
Entry  Fri Apr 18 08:17:38 2025, JM, More testing 15x
09:10

Arrived at GSI. Leakage currents status same as before, DSSD4 is still fluctuating. DSSD1 and DSSD3 currents are definitely lower again compared
to previous days. I am convinced they are decreasing over time, whether this will be enough for our measurement....
Entry  Mon Aug 9 12:36:00 2021, TD, RSS, ABD, Monday 9 August 7x

Attachments 1-5 - CARME shipment in CRYRING hall
                  XHV chambers nearest to YR09
Entry  Mon Apr 7 08:59:41 2025, TD, Monday 7 April 8x

10.00 FEE64 power ON
      CARME IE514 OFF
Entry  Mon Jan 29 15:32:08 2024, TD, JM, Monday 29 January contd. 16x

Test + and test - daisy chain cabling extended from DSSSD #1 to #2 to DSSSD #1 to DSSSD #4
 terminated by 50 Ohm at end of daisy chain
Entry  Mon Jan 29 08:52:07 2024, TD JM, Monday 29 January 32x

09.50 CARME IE514 5.1e-11 mbar ( ambient temperature 16 deg C )
Entry  Mon Nov 28 13:14:33 2022, AR TD, Monday 28 November 12x
 
Entry  Mon Feb 28 14:47:52 2022, CB, TD, Monday 28 February 15:00-23:00 17x

15.51 1.8.W spectra 20ms, 2ms, 200us, 20us FSR - attachments 1-8
Entry  Sun Apr 28 23:12:11 2024, TD, Monday 28 April 21x
00.09 DAQ continues data file R3_21

      DSSSD bias & leakage current OK - attachment 1
Entry  Mon Oct 2 08:41:43 2023, TD, Monday 2 October 6x
09.35 CARME IE514 1.95e-8 mbar, ambient temperature 20.8 deg C

      CARME bakeout monitor, ELOTECH R4000 temperature controller front panel and Grafana bakeout dashboard- attachments 1-3
Entry  Mon May 15 07:34:22 2023, TD, Monday 15 May 
08.35 DSSSD#3 bias -149.95V leakage current -6.418uA temperature +19.6 deg C ( https://web-docs.gsi.de/~lestinsk/tempplot.php )

DSSSD#3 bias OFF
Entry  Mon Jan 15 18:51:28 2024, JG, DR, TD, Monday 15 January 

Cooling water manifolds