AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DESPEC, Page 34 of 37  ELOG logo
Entry  Wed Jan 23 08:12:01 2019, CA, TD, NH, VP, January 22nd 2019 220119_18W.png220119_pulserpeaks.png220119_stats.png220119_Temp.png
Attachment 1 - 1.8.W waveform spectra with pulser signal

Attachment 2 - 1.8.L pulser peak spectra
Entry  Wed Jan 23 09:25:55 2019, CA, TD, NH, VP, MACB and setup pics 23.01.19 11x
Pictures of leaking cooling pipe

MACB switch settings
Entry  Wed Jan 23 17:03:08 2019, CA, TD, NH, VP, January 23rd 2019 6x
Post White Rabbit update

Attachment 1 - 1.8.W pulser waveform spectra for all FEE64
Entry  Thu Jan 24 10:21:26 2019, CA, TD, NH, VP, January 24th 2019 7x
10.30 AIDA setup and DAQ start complete
      writing to file TapeData/NULL/R1
Entry  Thu Jan 24 17:16:32 2019, CA, TD, NH, VP, MACB time switch settings 50668223_286084358731841_9104059387265155072_n.jpgdespecmacb.pdf
AIDA@DESPEC MACB time switch settings before and after WR are as follows.

Attachment 1 - MACB 1-4 from left to right
Entry  Fri Jan 25 09:54:12 2019, CA, TD, NH, VP, 25th January 2019 8x
09.30: AIDA still running, not writing to file
       Still running ok
       No water leaks
Entry  Wed Oct 30 08:06:49 2019, CA, TD, NH, DSSSD stack 6x
Ribbon cables fitted with kapton PCB couplers -> 3 isolated + 1 non-isolated for each cable length/DSSSD

Ribbon cable lengths:
Entry  Wed Oct 30 11:51:08 2019, CA, TD, NH, Detector biasing bias30Oct.png30Octbias2.pnghvsketch.pdf
12.51 - detector bias and leakage currents - detector 3 has no current
                                           - other detectors ok
Entry  Thu Oct 31 09:00:58 2019, CA, TD, NH, Thursday 31 October 14x
10.05 DSSSD # 1-3 detector biases & leakage currents OK - see attachment 1
      Ambient temperature +21.2 deg C, d.p. +3.4 deg C, RH 31.2%
Entry  Fri Nov 1 10:46:13 2019, CA, TD, NH, Friday 1st November 2019 6x
11.46 - attachments 1,2,3: bias/leakage currents, good event statistics and fee temperatures (respectively)
        before removing aluminium foil upstream of AIDA
Entry  Fri Nov 1 15:24:40 2019, CA, TD, NH, Summary - 29.10-1.11.19 

3x MSL type BB18(DS)-1000 installed 
    Reply  Fri Nov 1 15:45:04 2019, CA, TD, NH, Summary - 29.10-1.11.19 
>

> - evidence of c. 1MHz extrinsic noise for most FEE64s
    Reply  Fri Nov 1 18:09:03 2019, CA, TD, NH, Summary - 29.10-1.11.19 
> >
> > 
> > - evidence of c. 1MHz extrinsic noise for most FEE64s
Entry  Sat Mar 13 07:08:52 2021, CA, TD, LS, March 13th 08:00 - 17:00 20x
ASIC settings 2019Dec19-16.19.51
      DSSSD#1 slow comparator 0xa
      DSSSD#2 slow comparator 0xa
Entry  Mon Dec 10 11:09:53 2018, CA, TD, Scintillator pictures/system checks for 07.12.18 14x
11.12 System wide checks ok (attachment 1)
      FEE temperatures ok (attachment 2)
      bias/leakage currents ok (attachment 3)
Entry  Mon Apr 1 08:50:35 2019, CA, TD, Monday April 1st 2019 - BEAM START 18x
09.28 System wide checks - aida06 global clock failure (check clock status)

                         - aida02 , aida04, aida06 fail calibration (ADC calibration)
Entry  Wed Apr 3 15:24:06 2019, CA, TD, report - low inquire save state 030419_1614_savestate.png
On Save/Restore Module Settings Tab - "inquire save state" returns an error. See attachment 1.
Entry  Mon Mar 8 09:45:20 2021, CA, TD, Analysis R7_20 (new version of NewMerger with min info code 4 & 5 data items) R7_20R7_20_verbose

An analysis of file R6_70 can be found at https://elog.ph.ed.ac.uk/DESPEC/177 attachment 19
We observe c. 80M ADC data items per 2Gb file and c. 160M info code 4 & 5 data items.
Entry  Thu May 13 07:10:17 2021, CA, TD, May 13th 08:00 - 16:00 shift 34x
08:10 all system wide checks ok *except*

      all FEE64 modules fail ADC calibration
Entry  Thu Apr 11 15:28:10 2019, CA, OH, CB, TD, Offline analysis of 290319 files R13 and R16 6x
X projection of high energy channel ADC hits from R13 (attachment 1)

XY hit pattern from R13 (attachment 2)