Thu Apr 11 08:27:21 2024, JB, TD, 11 April noise tests 48x
|
TO-DO for 11.04.2024
- Try bringing bPlast drain wire ground back to the PSU ground for PN 300 and R&SRMP4040.
- Recheck the downstream detector bias and ground scheme.
-
9:27 Restarted AIDA and hit go at 9:54. Situation the same as it was in the evening of 10.04.2024. 10 out of 16 FEE64s in good condition. Waveforms of aida16,
TEMP OK - HV OK. See attachments 1-6.
10:20 We grounded the output of the R&SRMP4040 to to the drain wire ground of the bPlast ribbon cables and the output of the PN 300 PSU that is powering the booster boards. Results given by attachments 7 -11. We only saw a marginal improvement in the overall noise condition.
10:32 We connected the ground of the frame to the drain wire ground, that is also mutually connected to the ground of the R&SRMP4040 output ground and PN 300 output ground. Results given by attachments ???. We did not see any improvement in the overal noise condition.
11.00 DSSSD HV OFF
FEE64 power OFF
Check seating of all adaptor PCBs and drain/ground wires secured - generally OK
Restart
1.8.W spectra - 20us FSR - attachments 15-16
per FEE64 Rate spectra - attachment 17
10/16 < 20k, max 110k
ADC data item stats - attachment 18
Incremental improvement.
11.45 DSSSD HV OFF
FEE64 power OFF
test - daisy chain removed
Restart
1.8.W spectra - 20us FSR - attachments 20-21
per FEE64 Rate spectra - attachment 19
10/16 < 20k, max 210k
ADC data item stats - attachment 22
overall somewhat worse
12.20 DSSSD HV OFF
FEE64 power OFF
Re-install test - daisy chain, Tighten aida04 DSSSD ribbon cable drain wire.
Restart
1.8.W spectra - 20us FSR - attachments 23-24
per FEE64 Rate spectra - attachment 25
ADC data item stats - attachment 26
10/16 < 20k, max 110k
Status quo ante
aida04 & aida08 1*W & 2*W spectra - 200us FSR - attachments 27-31
large transients observed for aida04 1*W - cable or ASIC fault?
aida16 **W spectra - 200us FSR - attachments 32-35
all channels apopear to be working but mix of high/low noise channels for asics #3-4, asics #1-2 all appear high noise
14.00 DSSSD HV OFF
FEE64 power OFF
Disconnect ribbon cables from aida04 adaptor PCB
Restart
n+n FEE64 1.8.W spectra - 20us FSR - attachments 37
per FEE64 Rate spectra - attachment 36
ADC data item stats - attachment 38
Implies origin of large transients observed in aida04 asic#1 is downstream of the FEE64 adaptor PCB, i.e. ribbon cable or DSSSD.
14.40 DSSSD HV OFF
FEE64 power OFF
re-connect ribbon cables from aida04 adaptor PCB
1x pin J2 slightly bent - straightended with screwdriver - FFSD connector insertion OK
Restart
n+n FEE64 1.8.W spectra - 20us FSR - attachments 40-41
per FEE64 Rate spectra - attachment 42-43
ADC data item stats - attachment 39
10x < 20k, max 120k
aida11 asic#4 1.8.W spectra - 200us FSR - attachment
no large transients observed
DSSSD #1 & #2 bias from -120V to -100V
ADC data item stats - attachment 40
9x < 20k, max 220k (aida08)
per FEE64 Rate spectra - attachment 41
17.15 bPlas ON -
Current bPlast ground configuration:
bPlas current ground configuration - drainwires of all ribbon cables excluding short side (cont. with snout) are grounded back to the bPlast R&SRMP4040 PSU, on the 29 V output. 4 V PSU to booster boards are floating, output of PN 300 is grounded to the PSU. The mesytec PSU, that also powers bPlast SiPMs at
29V is not grounded to anything but the frame. Snout is currently light tight, I suspect internal radiation from FATIMA.
It is noted that bPlast current draw fluctuated significantly (+/- 300 mV) as a result of thresholds set to the detector. I tried to set the thresholds HIGH to stabilise the bPlast detector as the power draw is fluctuating greatly.
AIDA noise very good
ADC data item stats - attachment 42
12x < 20k, max 83k (aida04)
per FEE64 Rate spectra - attachment 43
To Do list
- separate 29V (low current) and 4V (high current) return paths/ground refs
- The mesytec PSU that powers the bPlast detector is running to frame, it might be an idea to ground ribbon c
|
Tue Apr 23 09:21:01 2024, PP, 10:20 checks - aida02 is down 8x
|
Aida02 is down. Contacted Nick.
The rest looks stable, see screenshots.
10:53 CEST (NH): Rebooted aida02 via telnet
Resync ASIC clocks
All system wide checks look ok
ASIC threshold => 0x14
Go > All 16 writing to merger, looks OK
aida02 went down again 11:35 CEST
Rebooted with same procedure and is back again |
Sun Apr 28 22:52:06 2024, Marc, 0:00-08:00 Monday 29 April 7x
|
Just another manic magic Monday, ....
Taking over Betool's AIDA shift. All is good.
This shift's first hour has been eventless. Temperatures, Rates, bias, all look good.
01:15: AIDA04 is down again. DAQ shift crew informed.
01:27: AIDA04 is back and shift crew has been informed.
01:30 Checks:
Bias and leakage current - Attachment 1-2
Temperatures - Attachment 3
ADC Data item - Attachment 4
Rate Spectra - Attachment 5
UCESB - Attachment 6
Timestamp checks - Attachement 7
06:00 It has run very smoothly.
|
Mon Mar 9 13:50:08 2020, LS, CA, DK, 09/03/2020 system checks 13x
|
14:52 Attachment 1 shows low energy spectra. AIDA06 shows strange baseline, possible double-hit?
15:06 Systems checks fine.
Master clock failed (no master clock)
all checks passed
memory checks all around 38k as normal
Attachment 2: Temperature check all normal except aida01 virtex temp slightly over 65 degrees
Attachment 3: Good event stats seem normal except downstream SSD seems to be high around 200k
Attachment 4: leakage currents seem normal at expected values
15:16 Merger working for all FEEs
tape server is on but no storage
data rate is around 25 MB per second (high but consistent with the high stats of downstream SSD)
ASIC controls checked and are all OK
15.48 low energy pulsar peak FWHM
fee FHWM
1 89.08
2 132.06
3 70.73
4 81.84
5 62.86
6 79.92
7 122.13
8 73.31
9 198.39
10 115.53
11 100.55
12 144.04
ALL FEEs in downstream SSD are high
16:21 included low energy pulsar peaks (Attachments 5 & 6) and waveforms for all FEEs (Attachments 7 & 8)
16:25 included rates, note not to common scale in y (attachment 9)
ASIC settings file 2019Dec19-16.19.51 but some others are on 2019Oct31-13.24.23
Did not seem completely reproducible?
We carefully checked all the individual FEE and ASIC settings, and they are all the same (except shaping reference), with NO 0xad
Now we made sure they are all using 2019Dec19-16.19.51 (which we had saved first on a good one)
19:15 Update
There is a safety interlock box in S4 to monitor humidity, dew point, temperature, etc for safety.
It had a loose solder connection, and when someone moved it out of the way, the interlock was tripped.
After some debugging, the interlock is now in a more stable condition, but a lot of power was cut from AIDA systems
One unusual thing was that one of the RPi systems got a full /var/messages (or similar) and ate all the available disk space
This meant that ssh -X (to, e.g., activate putty) could not work, giving a permission denial error (ssh connection was allowed, but not X11 forwarding)
Now we have brought back up the AIDA systems and should run through the checks
Most system checks look good (except some calibration errors)
Temps were running high until we reloaded the ASIC settings, then the temperatures began to cool
Bias and leak currents attached as #10
Temps as #11
Stats as #12
19:50 Started writing to disk so that we can do an implantation depth profile. Will analyse near online using AIDASort.
21:45 Stopped writing to file -> Runs where AIDA thickness were investigated corresponds to R3_62 to R3_72
A rough method using the rates histogram was used to judge roughly when depositing in each histogram - see attachment 12 (Stopping in 2)
Can match to the FRS files to work out degrader thickness with timestamps (File stopped at Mon 09 Mar 2020 09:44:51 PM CET
21:51 AIDA running to no storage again |
Wed Apr 24 09:04:55 2024, TD, 08:00-16:00 Wednesday 24 April 33x
|
09.56 DAQ continues data file S100_alpha/R18_122
FRS setting 162Eu
DSSSD bias & leakage current OK - attachments 1-2
FEE64 temperatures OK - attachment 3
aida02 ASIC temp - known fault
All system wide checks OK *except* as shown - attachments 4-6
WR timestamps OK - attachment 7
ASIC settings aida01 & aida02 - attachments 8-9
ADC, DISC, PAUSE, RESUME, WR & Correlation Scaler data time stats - attachments 10-15
per FEE64 Rate spectra - attachments 16-18
unusually can observe HEC Rates esp. in DSSSD #1
per p+n FEE64 1.8.L spectra - attachments 19-21
aida09 pulser peak width 61 ch FWHM
common x/y scale => peak height proxy for width => all p+n FEE64s similar pulser peak widths
per n+n FEE64 1.8.L spectra - attachment 22
per FEE64 1.8.H spectra - attachments 23-24
per FEE64 1.8.W spectra - 20us FSR - attachments 25-26
only aida08 & aida09 currently updating - ASIC check load and/or DAQ STOP/GO required?
Merger, TapeServer etc - attachments 27-28
ucesb - attachments 29-30
spill cycle reported as 3.5s, extraction 1.5s
10.36 All histograms & stats zero'd
BNC PB-5 settings - attachment 31
DSSSD bias & leakage current - Grafana Alerting - attachment 32
can observe bias & leakage current in greater detail
DSSSD #1 bias stable, c. 10s nA micro structure observed in leakage current
DSSSD #2 bias c. 10mV variations, micro structure observed in leakage current but smaller variations cf. DSSSD#1
10.46 analysis of data file R18_131
max dead time 12% aida04, 6% aida02, all others 0.1% or less
no timewarps
HEC data item rates 1.6kHz - correcting for spill cycle => 2.3kHz in spill (online analysis shows no HEC events observed outside spill)
assume typical HEC event multiplicity = 3 => implant rate ~ 760Hz in spill or 2700 implants per spill
SC42 L/R currently report c. 2kHz
|
Wed Jun 12 06:17:23 2024, TD, 08:00-16:00 Wednesday 12 June 24x
|
07:10 DSSSD bias & leakage current OK - attachment 1
FEE64 temperatures OK - attachment 2
ADC data items stats OK - attachment 3
per FEE64 Rate spectra - attachment 4
Merger, TapeServer etc - attachment 5
per p+n FEE64 1.8.L spectra - attachment 6
aida09 pulser peak width 68 ch FWHM
07.13 peak area 25253 total area 27548 in 221mins => 1.9-2.1Hz => deadtime < 5% or less which is consistent with data file analysis below
analysis data file S181/R6_274 - attachment
max FEE64 deadtime 24% aida08
HEC data rate 4.5kHz, LEC data rate 2.284M
14.00 DAQ crashed by accident
FEE64s power cycled
DAQ restarted
data file S181/R7
DSSSD bias & leakage current OK - attachments 8-9
FEE64 temperatures OK - attachment 10
ADC data item stats - attachment 11
WR timestamps OK - attachment 12
All system wide checks *except* as reported attachments 13-15
per FEE64 Rate spectra - attachment 16
per p+n FEE64 1.8.L spectra - attachment 17
aida09 pulser peak width 66 ch FWHM
per FEE64 1.8.H spectra - attachments 18-19
per FEE64 1.8.W spectra - 20us FSR - attachment 20-21
Merger, TapeServer etc - attachments 22-23
data file S181/R7_16
analysis data file S181/R7_16
max deadtime 7.3% aida08, all other FEE64s < 2%
LEC data rate 1.877M HEC data rate 4.7k |
Tue Apr 23 07:27:18 2024, PP, 08:00-16:00 Tuesday 24 April shift 8x
|
Checks 08:00-08:30
Screenshots are attached and everything looks OK. |
Tue Jun 11 10:03:48 2024, TD, NH, 08:00-16:00 Tuesday 10 June 23x
|
10.57 DSSSD bias & leakage current OK - attachment 1
FEE64 temps OK - attachment 2
ADC, MBS correlation scaler data item stats - attachments 3-4
ADC 9x < 20k, max 243k aida08
ASIC settings aida01 & aida02 - attachments 5-6
ALL system wide checks OK *except* attachments 7-8
WR timestamps OK - attachment 9
BNC PB-5 settings - attachment 10
per FEE64 Rate spectra - attachment 11
per p+n FEE64 1.8.L spectra - attachment 12
aida09 pulser peak width 57 ch FWHM
per FEE64 1.8.H spectra - attachments 13-14
per FEE64 1.8.W spectra - 20us FSR - attachments 15-16
no p+n FEE64 wavefroms - reason unknown
Merger, TapeServer etc - attachments 17-18
11.25 Lost control of aida-gsi window system
All command terminals lost, could not start new command terminals
aida-gsi restart
FEE64 power cycle
DSSSD bias cycle
Note file manager, calculator apps now working as expected
12.11 DAQ starts
data file S181/R6
ASIC settings 2024Apr19-15.22.49
BNC PB-5 Pulser
Amplitude 10.0V
Attenuation x10
Fall time 1ms
Frequency 2Hz
Polarity + (connected to test + signal daisy chain to all p+n FEE64s)
Sync ASIC clocks OK
All system wide checks OK *except* aida02 FPGA/WR decoder - attachments 19-20
per FEE64 1.8.W spectra - 20us FSR - attachments 21-22
12.29 analysis data file S181/R6_9 - attachment 23
max dead time c. 2% (aida08)
15:34 For some reason the AIDA MBS wasn't connecting to the time sorter (or a check stream) [NH]
Try to reset the AIDA MBS
Due to confusion the AIDA Merger was rebooted too, while the DAQ was running, this broke all the FEEs -> Powecycled
Synced ASIC clocks, fixed all waveforms
Masked all discriminators
All looks ok -> Sending back to MBS and back in DESPEC DAQ |
Thu Apr 25 08:26:50 2024, TD, 08:00-16:00 Thursday 25 April 42x
|
09.56 DAQ continues data file S100_alpha/R18_387
FRS switching settings
DSSSD bias & leakage current OK - attachments 1
FEE64 temperatures OK - attachment 2
aida02 ASIC temp - known fault
All system wide checks OK *except* as shown - attachments 3-5
WR timestamps OK - attachment 6
ADC, PAUSE, RESUME & Correlation Scaler data time stats - attachments 7-10
per FEE64 Rate spectra - attachments 11
per p+n FEE64 1.8.L spectra - attachments 12-13
aida09 pulser peak width 57 ch FWHM
common x/y scale => peak height proxy for width => all p+n FEE64s similar pulser peak widths
per n+n FEE64 1.8.L spectra - attachment 14
per FEE64 1.8.H spectra - attachments 15-16
per FEE64 1.8.W spectra - 20us FSR - attachments 17-18
only aida08 & aida09 currently updating - ASIC check load and/or DAQ STOP/GO required?
Merger, TapeServer etc - attachments 19-21
BNC PB-5 settings - attachment 22
10.07 data file S100_alpha/R20
new run for new FRS setting
10.08 all histograms, stats, merger stats and data link stats zero'd
10.10 ADC data item stats (beam OFF) - attachment 23
11/16 < 20k, max 129k (aida08)
10.31 analysis of data file R18_349 (closed 06.00 this morning)
max deadtime 12% (aida04)
no timewarps
HEC data item rate 1.7kHz
11.00 tuning 168dy FRS setting
ucesb - attachment 24
spill length 3.5s, extraction time 1.5s
11.30 degraders now set to implant in AIDA DSSSDs
high rates expected
per FEE64 Rate spectra - attachment 25
ADC data item stats - attachment 26
Merger etc - attachment 27
in spill rates to MBS up 30+Mb/s, 2.5M data item/s merged
DSSSD bias & leakage current - attachment 28
c. few hundred nA step in leakage current
analysis of data file R20_33 - attachment 29
max deadtime 18% (aida08)
no timewarps
HEC data item rate 4.1kHz (c. 2.4x previous FRS setting)
Correcting for spill cycle => 5.9kHz in spill (online analysis shows no HEC events observed outside spill)
assume typical HEC event multiplicity = 3 => implant rate ~ 2.0kHz in spill or 6800 implants per spill
SC42 L/R currently report c. 4.5kHz
Note that we currently see a higher fraction of events in DSSSD#2 cf. previous setting so multiplicity assumption may be low
If we assume multipicity = 6 => implant rate ~ 1.0kHz in spill or 3200 implants per spill
we are probably somewhere in between
12.50 DSSSD bias & leakage current - Grafana - attachment 30
leakage current ramping, spill micro structure observable
FEE64 temperatures OK - attachment 31
ADC data item stats - attachment 32
per FEE64 Rate spectra - attachment 33
Merger etc - attachment 34
14.56 analysis of data file R20_106 - attachment 35
max deadtime c. 18% (aida04 & aida08), c. 12% (aida03), c. 11% (aida06), c. 9% (aida02 & aida13), c. 6% (aida05), all others <2%
no timewarps
HEC data item rate 4.2kHz
15.40 DSSSD bias & leakage current - Grafana - attachments 36-37
leakage current ramping, spill micro structure observable
FEE64 temperatures OK - attachment 38
ADC data item stats - attachment 39
per FEE64 Rate spectra - attachment 40
Merger etc - attachment 41
ucesb - attachment 42
15.57 all histograms zero'd
|
Sun Apr 28 06:57:59 2024, Magda Satrazani, 08:00-16:00 Sunday 28 April 36x
|
Took over the shift from Marc.
10.51 Added screenshots to illustrate erroneous data from Grafana (AIDA) - attachments 18-19
Compare to the CAEN HV control terminal (attachment 15) which shows the expected values. Have email'd Nic & Helena. TD
10.55 Noticed that the CAEN HV control terminal is showing the corerct data but on the wrong line of the display (attachment 15). Enter commands q (quit) and d (display) to restart display - the correct data now appears on the correct line (attachment 20).
Grafana (AIDA) is now reporting data correctly too (attachment 21).
Summary - CAEN HV terminal display issue ( c. 10.05 - 10.55 )
Note the correct data/values continued to be shown. Leakage current shown correctly by both Grafana and CAEN HV control throughout.
Conclude this was a display issue - not a change in the operating parameters of the CAEN N1419ET.. Data should be OK.
14.45 analysis data file R21_500 - attachment 36
max deadtime 22% (aida11), 16% (aida04), 7% (aida02), 6% (aida08), 6% (aida06) , all others < 1%
no timewarps
HEC data item rate 2.7kHz
|
Sat Apr 27 04:59:31 2024, TD, 08:00-16:00 Saturday 27 April 37x
|
06.00 DAQ continues file S100_alpha/R20_740
FRS setting 162Eu
DSSSD bias & leakage current - Grafana - attachments 1-2
leakage currents tracking S4 ambient temperature
FEE64 temperatures OK - attachment 3
All system wide checks OK *except*
as reported - attachments 4-5
*all* ADCs not calibrated (not calibrated post-synchronise ASIC clocks at most recent restart)
WR timestamps OK - attachment 6
ADC, PAUSE, RESUME, Correlation scaler data item stats OK - attachments 7-10
per FEE64 Rate spectra - attachment 11
per p+n FEE64 1.8.L specra - attachments 12-13
aida09 pulser peak width 55 ch FWHM (~38keV FWHM)
per FEE64 1.8.H spectra - attachments 14-15
Merger, TapeServer etc - attachments 16-17
12Mb/s to disk
ucesb - attachment 18
spill length 3.5s, extraction 1.5s
06.30 analysis data file R20_748 - attachment 19
max deadtime 12%
no timewarps
HEC data item rate 2.1kHz
06.35 new run file S100_alpha/R21
09.30 DAQ continues - file S100_alpha/R21_83
DSSSD bias & leakage currents - Grafana - attachment 20
FEE64 temperatures OK - attachment 21
ADC data item stats OK - attachments 22
per FEE64 Rate spectra - attachment 23
Merger etc - attachments 24
ucesb - attachment 25
spill length 3.5s, extraction 1.5s
09.50 per FEE64 1.8.W spectra - 20us FSR - attachments 26-27
no significant change in electronic noise cf. start of run
per p+n FEE64 1.8.L spectra - attachment 28
aida09 pulser peak width 62 ch FWHM
common x/y scale - peak heoght proxy for width
13.57 DAQ continues file R21_141
DSSSD bias & leakage current - Grafana - attachments 29-30
FEE64 temperatures OK - attachment 31
ADC data item stats OK - attachments 32
per p+n FEE64 1.8.L spectra - attachment 33
aida09 pulser peak width 55 ch FWHM (~39keV FWHM)
per FEE64 Rate spectra - attachment 34
Merger etc - attachments 35
ucesb - attachment 36
spill length 3.5s, extraction 1.5s
14.15 analysis data file R21_144 - attachment 35
max deadtime 16% (aida04)
no timewarps
HEC data item rate 2.0kHz |
Fri Jun 14 06:22:39 2024, TD, 08:00-16:00 Friday 14 June 23x
|
07.23 All histograms & stats zero'd
DAQ continues data file S181/R8_35
analysis data file R8_35 - attachment 1
max deadtime 4.8% (aida08), all other FEE64s < 3%
LEC data rate 1.677M HEC data rate 3.7k
08.46 DSSSD bias & leakage current OK - attachments 2-3
FEE64 temps OK - attachment 4
ADC data item stats - attachment 5
per FEE64 Rate spectra - attachment 6
per p+n FEE64 1.8.L spectra - attachment 8
aida09 pulser peak width 65 ch FWHM
per FEE64 1.8.H spectra - attachment 7 & 10
per FEE64 1.8.W spectra - 20us FSR - attachment 9 & 11
Merger, TapeServer etc - attachments 12-13
data file S181/R8_72
10.51 DSSSD bias & leakage current OK - attachments 14
FEE64 temps OK - attachment 15
ADC data item stats - attachment 16
per FEE64 Rate spectra - attachment 17
10.54 analysis data file R8_122 - attachment 18
max deadtime 7.8% (aida08), all other FEE64s < 3%
ADC data rate 1.88M, HEC data rate 4.7k
14.24 DSSSD bias & leakage current OK - attachments 18
FEE64 temps OK - attachment 19
ADC data item stats - attachment 20
per FEE64 Rate spectra - attachment 21
aida02 no data
14.28 merger restarted and DAQ running OK
14.38 analysis data file R8_213 - attachment 22
max deadtime 6.6% (aida08), all other FEE64s < 3.5%
ADC data rate 1.935M, HEC data rate 3.6k |
Thu Jun 13 06:49:54 2024, Magda Satrazani, 08:00 - 16:00 Thursday 13 June 2024 40x
|
Took over the shift from Marc.
08:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 1-2
FEE64 temperatures ok - attachment # 3
ADC data item stats - attachment # 4
Merger ok - Attachement # 5
Tape service - attachement # 6
10:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 7-8
FEE64 temperatures ok - attachment # 9
ADC data item stats - attachment # 10
Merger ok - Attachement # 11
Tape service - attachement # 12
12:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 13-14
FEE64 temperatures ok - attachment # 15
ADC data item stats - attachment # 16
Merger ok - Attachement # 17
Tape service - attachement # 18
12.34 analysis data file S181/R7_610 - attachment 19
max deadtime 8.7% (aida08), all other FEE64s < 2.7%
LEC data rate 2.000M, HEC data rate 4.7k
12.52 per p+n FEE64 1.8.L spectra - attachment 20
aida09 pulser peak width 63 ch FWHM
per FEE64 1.8.H spectra - attachments 21-22
per FEE64 1.8.W spectra - 20us FSR - attachments 23-24
13.00 all histograms zero'd
14:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 19-20
FEE64 temperatures ok - attachment # 21
ADC data item stats - attachment # 22
Merger ok - Attachement # 23
Tape service - attachement # 24
13.01 Beam OFF for S4 access
ADC data item stats - attachment 25
per FEE64 Rate spectra - attachment 26
14.12 analysis data file R7_654 - attachment 27
max deadtime 3.9% (aida08), all other FEE64s < 3%
LEC data rate 1.817M, HEC data rate 2.5k
14.00 data file R7_649 - attachment 28
max deadtime 4.5% (aida08), all other FEE64s < 3%
LEC data rate 1.756M, HEC data rate 2.5k
16:00 FULL CHECK
DSSSD bias & leakage current ok - attachment # 25-26
FEE64 temperatures ok - attachment # 27
ADC data item stats - attachment # 28
Merger ok - Attachement # 29
Tape service - attachement # 30 |
Fri Apr 26 07:01:26 2024, Norah, 08:00 - 16:00 Friday 26 April    
|
10:00 Checks:
All seems smooth.
DSSD bias and leakage current ( Attachment 1)
FEE64 temperatures (Attachment 2)
Per FEE64 Rate spectra (Attachment 3)
ADC data item stats -(Attachment 4)
Ucesb (Attachment 5)
10:21
Aida05 was zero not reading had to call Nic to fix it.
10:34
Now, Aida05 is running well.
.......................................................
12:00 Checks:
Everything appears to be going smoothly, and I took screenshot of them.
12:28, Aida02 showed as not reading , had to email Nic to fix it.
12:30, it resumed reading and returned to normal operation.
.........................................................
14:00 Checks:
Everything is going well , and I have captured screenshots of each one.
......................................................
16:00 Checks:
All seems smooth, and I took screenshot of them.
|
Mon Jun 10 07:15:48 2024, Dan, 08.00-16.00 Monday 10th June 50x
|
8am checks
temps ok - attachment 2
rates ok - attachment 8
voltage ok - attachment 5
merger ok - attachment 6
9am checks
temps ok - attachment 10
rates ok - attachment 9
voltage ok - attachment 12
merger ok - attachment 11
(Ignore Grafana plots 13-43 inc - not refreshed)
9.16 beam stopped to optimise beam intensity
10.00 checks - still no beam
temps ok - attachment 17
rates ok - attachment 15+16
voltage ok - attachment 14
merger ok - attachment 18
11.00 checks - still no beam
temps ok - attachment 23
rates ok - attachment 21+22
voltage ok - attachment 20
merger ok - attachment 24
12pm checks
temps ok - attachment 28
rates ok - attachment 26+27
voltage ok - attachment 29
merger ok - attachment 30
12.45 - beam back
temps ok - attachment 34
rates ok - attachment 32+33
voltage ok - attachment 35
merger ok - attachment 36
2pm checks
temps ok - attachment 40
rates ok - attachment 38+39
voltage ok - attachment 41
merger ok - attachment 42
/tmp/R4_276 added - attachment 44
max deadtime 10.5% (aida08)
n+n FEE64s deadtime
3pm checks
temps ok - attachment 48
rates ok - attachment 46+47
voltage ok - attachment 45+50
merger ok - attachment 49 |
Mon Jun 3 14:40:34 2024, JB, NH, 03 June 2024 10x
|
15:40 reseated FEE64s adaptors of aida01, aida09, aida13 & aida16.
TEMP OK. HV OK. System wide checks all passed excl. aida07 ADC calibration, see attached.
Histograms and rates look same as previous, reseating aida01 seems to have worked. aida16 still unhappy.
re-reseated aida16. 16:19 - appears to have fixed the problem in the channel.
Pulser test + connected.
bPlast ground removed from frame.
To-do:
- Need clarification about links connected on AIDA n+n FEE64 adaptor boards. Currently, the situation is given by the attachment 8 & 9.
- Fix BB7 grounding, continuity between snout and frame observed.
- Pulser walkthrough for n+n, can do p+n when convienient.
18.30 Noted FEE64 ADC stats now significantly higher ( attachments 9-10 ) cf. earlier this afternoon (attachments 1-2)
DSSSD bias OFF. FEE64 power OFF.
|
Tue Apr 23 22:37:46 2024, TD, 00:00-08:00 Wednesday 24 April 18x
|
23.34 23.4.24
DSSSD bias & leakage current OK - attachment 2
FEE64 temperatures OK - attachment 2
ADC data item stats - attachment 3
per FEE64 rate spectra - attachments 4
Merger etc - attachment 5
03.41 fDSSSD bias & leakage current OK - attachment 6
FEE64 temperatures OK - attachment 7
ADC data item stats - attachment 8
per FEE64 rate spectra (off and on spill) - attachments 9-10
Merger etc - attachment 11
03.54 analysis data file R18_67 - attachment 12
max deadtime 11% (aida04)
HEC data item rate c. 1.5kHz
no timewarps
0.35 fDSSSD bias & leakage current OK - attachment 13
FEE64 temperatures OK - attachment 14
ADC data item stats - attachment 15
per FEE64 rate spectra - attachments 16
Merger etc - attachment 17
03.54 analysis data file R18_96 - attachment 18
max deadtime 12% (aida04)
HEC data item rate c. 1.6kHz
no timewarps |
Tue Jun 11 23:13:44 2024, TD, 00:00-08:00 Wednesday 11 June 18x
|
00.08 DSSSD bias & leakage current OK - attachment 1
FEE64 temperatures OK - attachment 3
ADC data items stats OK - attachment 2
per FEE64 Rate spectra - attachment 7
per p+n FEE64 1.8.L spectra - attachments 6
aida09 pulser peak width 63 ch FWHM
Merger, TapeServer etc - attachments 4-5
analysis data file S181/R6_274 - attachment 8
max FEE64 deadtime 19% aida08
HEC data rate 3.8kHz, LEC data rate 2.258M
per FEE64 1.8.W spectra - 20us FSR - attachments 9-10
03.12 Merger, TapeServer etc - attachments 11-12
before & after Merger restart
per FEE64 Rate spectra - attachment 13
ADC data items stats OK - attachment 14
aida02 zero rate
FEE64 temperatures OK - attachment 15
DSSSD bias & leakage current OK - attachment 16
analysis data file S181/R6_372 - attachment 17
max FEE64 deadtime 22% aida08
HEC data rate 4.4kHz, LEC data rate 2.295M
03.32 all histograms zero'd
03.57 per p+n FEE64 1.8.L spectra - attachment 18
25 mins = 1500 @ 2Hz = 3000 cf. peak area c. 3000 => deadtime low |
Wed Apr 24 21:39:51 2024, TD, 00:00-08:00 Thursday 25 April 12x
|
22.43 24.4.24
DSSSD bias & leakage current OK - attachment 1
FEE64 temperatures OK - attachment 2
ADC data item stats - attachment 3
per FEE64 rate spectra - attachments 4
Merger etc - attachment 5
analysis of data file R18_266 - attachment 6
max dead time 12% (aida04)
no timewarps
HEC data item rate 1.7kHz
03.37 DSSSD bias & leakage current OK - attachments 7-8
FEE64 temperatures OK - attachment 9
ADC data item stats - attachment 10
per FEE64 rate spectra - attachments 11
Merger etc - attachment 12 |
Wed Jun 12 23:00:16 2024, Marc, 00:00-08:00 Thursday 13 June 23x
|
Starting a new night shift - All good
1am full check:
DSSSD bias & leakage current ok - attachment # 1-2
FEE64 temperatures ok - attachment # 3
ADC data item stats - attachment # 4
Merger ok - Attachement # 5
Tape service - attachement # 6
2:30am: AIDA02 FEE stopped working. DESPEC main DAQ was alerted and remobe AIDA from timestitcher while I was restarting AIDA DAQ.
2:45am: AIDA02 FEE is back and AIDA has been added to the timestitcher again in the main DAQ.
The AIDA runs at the time of the crash to look at are R7_348, 349.
All spectra were zeroed at this time and checked.
4:00 am full check:
DSSSD bias & leakage current ok - attachment # 7-8
FEE64 temperatures ok - attachment # 9
ADC data item stats - attachment # 10
Merger ok - attachement # 11
Tape service - attachement # 12
Spectra - attachement # 13
ucesb - attachement # 14
6:00am full check:
DSSSD bias & leakage current ok - attachment # 15-16
FEE64 temperatures ok - attachment # 17
ADC data item stats - attachment # 18
Merger ok - attachement # 19
Tape service - attachement # 20
Spectra - attachement # 21
ucesb - attachement # 22
6:30 the nearline/offline analysis team reported possible noise issue in DSSD#2 and asked if the threshold were changed at any point. I can't find any mention of changes in the elog.
I've not done a setup of the all DAQ when AIDA02 fee crashes earlier this morning. I just did a setup of the merger. Thus I don't think the threshold have changed when I stopeed and restarted the DAQ.
I can see that currently slow comparator threshod are set to 0xa for most of the DSSD2 fees except for AIDA06 which is set to 0xf. I'm not sure this is the thershold we would need to increase. Something to check during the next shift.
In the UCESB window I can see that the number of decay in DSSD2 is double the number of decay in DSSD1 while the number of implant is similar. Looking at other shift it looks that this was alsready the case in prvious shifts.
07.06 analysis of data file S181/R7_457 - attachment 23
max deadtime 5.8% aida08, all other FEE64s < 1.4%
LEC data rate 1.788M, HEC data rate 4.3k
|
|