Entry  Thu May 20 07:03:02 2021, CA, Thursday May 20th 08:00 - 16:00 shift 40x
08:00 CA takes over

08:04 DAQ continues ok - writing to file R14_989

09:30 all system wide checks ok *except* WR decoder status;

      
		 Base 		Current 	Difference
aida05 fault 	 0x500 : 	 0x56a : 	 106  
White Rabbit error counter test result: Passed 15, Failed 1

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

09:34 temperatures ok - attachment 1
      stats ok - attachment 2
      bias/leakage currents ok - attachment 3
      R14_1016 analysis - max deadtime ~4.3% - attachment 4

11:30 all system wide checks ok *except* WR decoder status;

		 Base 		Current 	Difference
aida05 fault 	 0x500 : 	 0x56b : 	 107  
White Rabbit error counter test result: Passed 15, Failed 1

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

11:34 temperatures ok - attachment 5
      stats ok - attachment 6
      bias/leakage currents ok - attachment 7
      R14_1052 analysis - max deadtime ~3.6% - attachment 8

13:05 beam optimisation currently taking place
      DAQ continues ok and writing to file R14_1085

13:17 no beam

13:28 all system wide checks ok, WR decoder status difference same as entry at 11:30.

13:31 temperatures ok - attachment 9
      stats ok - attachment 10
      bias/leakage currents ok - attachment 11
      R14_1085 analysis (beam off) - max deadtime ~1.34% - attachment 12

13:37 beam is back - rate spectra - attachment 13
      DAQ ok - writing to file R14_1088

13:43 analysis of R14_1088 - max deadtime back up to ~4.5% - attachment 14

14:21 beam off - issue with UNILAC
      DESPEC also report issues with their DAQ
      AIDA continues to forward data to MBS ok - lower rates while beam off

14.30 1.8.H spectra - attachments 16-18
      1.8.L spectra - attachments 19-22
       aida01 pulser peak width 99 ch FWHM
      Rate spectra - attachment 23
      Grafana - DSSSD bias & leakage currents past 7 days - attachment 24
      DSSSD bias & leakage currents - attachment 25
      Merger/Tape Server/Merger stats - attachment 26



14.41 All histograms & stats zero'd

14.55 Lost Activity Monitors - attachments 27, 28 & 35
      Stats - ADC data items, disc, good wave, WR 28-47, pause, correlation scaler

15:00 beam is back

15:05 AIDA writing to file R14_1108
      ADC data items - attachment 36

15:27 system wide checks ok *except* WR decoder status

      		 Base 		Current 	Difference
aida05 fault 	 0x500 : 	 0x56c : 	 108  
White Rabbit error counter test result: Passed 15, Failed 1

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

15:30 temperatures ok - attachment 37
      stats ok - attachment 38
      bias/leakage currents ok - attachment 39
      R14_1113 analysis (beam off) - max deadtime ~4% - attachment 40
Entry  Thu Mar 7 11:09:05 2024, HA, JB, CC, TD, MG, Thursday 7 March 
Snout assembly

DSSSDs

Upstream   3208-10/3208-18/3208-20
Downstream 3131-5/3131-10/3131-12

p+n junction side bias continuity checked OK for *all* wafers
 all c. 22 Ohm as expected

n+n Ohmic side bias continuity checked OK for both DSSSDs
 upstream 73 Ohm, downstream 92 Ohm

n+n Ohmic side bias wafer #2 
 positioned at top of snout assembly ( lower stage snout side marked 'T' )

p+n junction side faces downstream


Distances

Using top edge of lower stage snout as reference

ref - middle of upstream bPlas 8.0cm
ref - upstream DSSSD 11.0cm
ref - downstream DSSSD 12.0cm
ref - middle of downstream bPlas 14.0cm

Measurements consistent to +/-1mm between LHS and RHS of snout assembly as viewed from top side 


13.00 At this position the Kapton PCBs bulged in/out and there was some concern that when the upper stage
snout was installed it would the Kapton PCBs into the 'active' area. It was decided to move the 2x bPlas
and 2x DSSSDs c. 5mm downstream.

Jeroen and Phillip cut sections from 4x PEEK 6mm spacers so that they would clip onto 3mm dia support rods.

We raised the assembly fro the inter stage and inserted the modified spacers between the inter stage and 
the other spacers above. The Kapton PCBs now run fairly straight to the DSSSD connectors.

Distances re-measured as

Using top edge of lower stage snout as reference

ref - middle of upstream bPlas 8.6cm
ref - upstream DSSSD 11.5cm
ref - downstream DSSSD 12.4cm
ref - middle of downstream bPlas 14.5cm
Entry  Thu Apr 7 12:42:14 2022, OH, NH, TD, Thursday 7 April 8x
Re-assembled triple snout re-installed on the AIDA stand - DSSSD ribbon cables and grounds re-connected.
FEE64 adaptor PCB LKs per https://elog.ph.ed.ac.uk/DESPEC/409

Attachments 1 & 2 1.8.L spectra
  p+n FEE64 aida10 pulser peak width 97 ch FWHM
  n+n FEE64 aida04 pulser peak width 550 ch FWHM

Attachment 3 rate spectra
  missing channels aida01, aida07 & aida11 - misaligned ERNI and/or Samtec connectors?

Attachments 4 & 5 1.8.W spectra 

Attachment 6 ADC data item rates
 aida10 OK, all others c. 300-400k

Attachment 7 FEE64 temperatures OK

Attachment 8 DSSSD bias & leakage currents OK
Entry  Thu Jun 6 11:13:29 2024, TD, Thursday 6 June 9x
12.09 DSSSD bias & leakage current - attachment 1

      FEE64 temperatures OK - attachment 2

      ADC data item stats - attachment 3
      8x < 20k, max 247k aida08

      per FEE64 Rate spectra - attachment 4

12.16 all histograms & stats zero'd


21.08 DSSSD bias & leakage current - attachments 5-6

      FEE64 temperatures OK - attachment 7

      ADC data item stats - attachment 8
      8x < 20k, max 230k aida08

      per FEE64 Rate spectra - attachment 9


      
Entry  Fri Mar 5 22:53:05 2021, OH, Thursday 5th of March 
There has been no beam for much of the day. It was lost at 13:00 and not regained until 22:00 German time.
At some point during the day the White Rabbit timestamp cable was unplugged from AIDA. This caused it lose correlation with the rest of the system.
At first a reset and setup was performed to try and regain correlation but that did not prove successful.
A full powercycle was then performed at ~22:30 German time which upon restarting the DAQ solved the issue.

The plan is to overnight run some fragments, for the purposes of observing the isomers. This data is not essential and as such we will not be writing to disk.

Beam plug is in front of AIDA. This is causing a huge spike in the Ge.
Entry  Thu Oct 31 09:00:58 2019, CA, TD, NH, Thursday 31 October 14x
10.05 DSSSD # 1-3 detector biases & leakage currents OK - see attachment 1
      Ambient temperature +21.2 deg C, d.p. +3.4 deg C, RH 31.2%

10.15 DSSSD stack as follows

      DSSSD  serial  thickness  depletion 
      #              (um)       voltage (V)
      1      3208-7  1019       125              upstream
      2      3208-13 1020       120
      3      3208-14 1020       130              downstream

11.30 AIDA power relays sequenced on
      
      DAQ start

      system wide checks ok

11.33 attachment 2 - fee temperatures - ok

      attachment 3 - good event statistics with slow comparator threshold = 100

      attachment 4 - good event statistics with slow comparator threshold = 50

      attachment 5 - good event statistics with slow comparator threshold = 20

      attachment 6 - good event statistics with slow comparator threshold = 10
     
13.51 attachment 7 - Rates
                   - aida09 1 ASIC not working (no data)

      attachment 8 - good event statistics

      attachments 9/10 - 1.8.L spectra
                       - no peak observed in aida09

      attachments 11/12 - 1.8.W spectra
                        - waveform only observed in naida 2,4,7,8,12

      pulser peak widths -   FEE         width(ch)
                              1             71
                              2             96
                              3             66
                              4             79
                              5             74
                              6             96
                              7             89
                              8             83
                              9           no peak
                              10            82
                              11            153
                              12            120

17.26 FATIMA moved upstream around AIDA

      attachment 13 - good event statistics

      ASIC check-load performed

      attachment 14 - good event statistics following checkload
Entry  Thu Jun 3 10:16:39 2021, TD, Thursday 3 June 8x
11.19 Hot HEC channels multiple FEE64s
      ASIC check fixes

      System wide checks OK * except*

		 Base 		Current 	Difference
aida01 fault 	 0x8940 : 	 0x8941 : 	 1  
aida02 fault 	 0x9b32 : 	 0x9b33 : 	 1  
aida03 fault 	 0xf266 : 	 0xf267 : 	 1  
aida04 fault 	 0x579b : 	 0x579c : 	 1  
White Rabbit error counter test result: Passed 12, Failed 4

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

Returned 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0  
Mem(KB) :	4	8	16	32	64	128	256	512	1k	2k	4k
aida01 :     11      4      2      2      2      2      2      3      2      4      7   : 41516
aida02 :     10      7      2      0      1      2      2      3      2      4      7   : 41408
aida03 :     10      8      2      2      2      4      1      4      2      3      7   : 40008
aida04 :      5      4      4      2      2      3      1      4      2      3      7   : 39860
aida05 :     12      3      2      2      1      2      2      3      2      4      7   : 41448
aida06 :     15      9      2      2      3      2      1      3      2      4      7   : 41380
aida07 :     12      8      1      2      2      3      3      2      2      4      7   : 41408
aida08 :      9      6      3      1      2      3      3      2      2      4      7   : 41380
aida09 :     15      6      1      1      2      2      2      3      2      4      7   : 41500
aida10 :     15      6      3      2      1      3      3      2      1      4      7   : 40348
aida11 :      8      2      1      1      1      3      1      3      2      4      7   : 41248
aida12 :     18      3      2      1      3      3      2      2      2      4      7   : 41184
aida13 :      7      4      1      4      3      4      3      3      1      4      7   : 41100
aida14 :     18      6      1      4      3      4      2      2      1      4      7   : 40392
aida15 :      7      7      1      3      1      2      1      3      2      4      7   : 41220
aida16 :      4      4      2      3      3      3      2      4      1      4      7   : 41200

Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same

 FEE : aida01 =>   Options file size is 1026 	 Last changed Wed Jun 02 16:27:30 CEST 2021
 FEE : aida02 =>   Options file size is 1025 	 Last changed Sun May 23 00:19:21 CEST 2021
 FEE : aida03 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:43:50 CEST 2021
 FEE : aida04 =>   Options file size is 1025 	 Last changed Fri May 14 16:54:56 CEST 2021
 FEE : aida05 =>   Options file size is 1025 	 Last changed Mon May 17 06:25:41 CEST 2021
 FEE : aida06 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:43:59 CEST 2021
 FEE : aida07 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:02 CEST 2021
 FEE : aida08 =>   Options file size is 1025 	 Last changed Sun May 23 00:16:54 CEST 2021
 FEE : aida09 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:08 CEST 2021
 FEE : aida10 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida11 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida12 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida13 =>   Options file size is 1025 	 Last changed Fri May 07 19:40:34 CEST 2021
 FEE : aida14 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida15 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida16 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021


      Grafana - DSSSD bias & leakage current - most recent 7 days - attachment 1
      1.8.W spectra - 20us FSR - attachments 2 & 3
      ADC data items - attachment 4
      FEE64 temperatures OK - attachment 5
      DSSSD bias & leakage currents OK - attachment 6
      Merger/Tape Server/Merger statistics - attachment 7
       no merger errors reported since previous restart

11.43 Fixed merger issue which stopped output from merger - see https://elog.ph.ed.ac.uk/DESPEC/36

13.09 analysis of file S496/R31_16 - attachment 8
       max deadtime 0.31% aida04
Entry  Thu May 27 12:25:53 2021, TD, Thursday 27 May 9x
13.29 DAQ continues - file S496/R18_443
      alpha background

      All system wide checks OK *except*

FEE64 module aida06 global clocks failed, 6
 Clock status test result: Passed 15, Failed 1

Understand status as follows
Status bit 3 : firmware PLL that creates clocks from external clock not locked
Status bit 2 : always logic '1' 
Status bit 1 : LMK3200(2) PLL and clock distribution chip not locked to external clock
Status bit 0 : LMK3200(1) PLL and clock distribution chip not locked to external clock
If all these bits are not set then the operation of the firmware is unreliable

		 Base 		Current 	Difference
aida01 fault 	 0x82b0 : 	 0x82b2 : 	 2  
aida02 fault 	 0xfe72 : 	 0xfe74 : 	 2  
aida03 fault 	 0x97f4 : 	 0x97f6 : 	 2  
aida04 fault 	 0x950 : 	 0x952 : 	 2  
aida05 fault 	 0x8e93 : 	 0x8e95 : 	 2  
aida06 fault 	 0x545a : 	 0x545c : 	 2  
aida07 fault 	 0xc04d : 	 0xc04f : 	 2  
aida08 fault 	 0xa0f7 : 	 0xa0f9 : 	 2  
White Rabbit error counter test result: Passed 8, Failed 8

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

Returned 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0  
Mem(KB) :	4	8	16	32	64	128	256	512	1k	2k	4k
aida01 :      2      7      7      1      3      2      2      2      2      4      6   : 37008
aida02 :      3      1      5      1      3      4      3      3      2      4      6   : 37956
aida03 :      2      6      5      6      2      4      2      3      3      3      6   : 36808
aida04 :     24     12      5      5      4      3      2      3      3      3      6   : 36912
aida05 :      8      1      9      3      2      2      2      2      2      4      6   : 37016
aida06 :      3      6      2      2      2      2      2      3      3      4      6   : 38428
aida07 :      6     17      1      2      0      3      3      2      2      4      6   : 37232
aida08 :      4      2      1      2      3      4      3      3      2      4      6   : 37936
aida09 :     15      7      5      2      3      4      3      3      1      4      6   : 37060
aida10 :      7      6      9      2      0      3      3      3      1      4      6   : 36764
aida11 :     19     10      2      0      2      3      3      3      1      4      6   : 36796
aida12 :     11      6      4      2      2      4      2      3      2      4      6   : 37724
aida13 :     17      9      2      0      0      4      2      2      2      4      6   : 37036
aida14 :     15      4      7      1      1      3      2      2      2      4      6   : 37036
aida15 :      9      6      1      2      1      3      3      4      2      4      6   : 38244
aida16 :     11     11      8      2      0      3      2      2      2      4      6   : 37060

Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same

 FEE : aida01 =>   Options file size is 1026 	 Last changed Sun May 23 12:04:25 CEST 2021
 FEE : aida02 =>   Options file size is 1025 	 Last changed Sun May 23 00:19:21 CEST 2021
 FEE : aida03 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:43:50 CEST 2021
 FEE : aida04 =>   Options file size is 1025 	 Last changed Fri May 14 16:54:56 CEST 2021
 FEE : aida05 =>   Options file size is 1025 	 Last changed Mon May 17 06:25:41 CEST 2021
 FEE : aida06 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:43:59 CEST 2021
 FEE : aida07 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:02 CEST 2021
 FEE : aida08 =>   Options file size is 1025 	 Last changed Sun May 23 00:16:54 CEST 2021
 FEE : aida09 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:08 CEST 2021
 FEE : aida10 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida11 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida12 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida13 =>   Options file size is 1025 	 Last changed Fri May 07 19:40:34 CEST 2021
 FEE : aida14 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida15 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021
 FEE : aida16 =>   Options file size is 1014 	 Last changed Thu Apr 29 14:44:57 CEST 2021

      Grafana - DSSSD bias & leakage current - most recent 7 days - attachment 1
      Lost activity monitor - attachment 2
      1.8.W spectra - attachments 3 & 4
      ADC data item stats - attachment 5
      FEE64 temps OK - attachment 6
      DSSSD bias & leakage current OK - attachment 7
      Merger/Tape Server/Merger stats - attachment 8
       no merger errors reported since previous restart

14.30 analysis of file S496/R18_442 - attachment 9
       max deadtime 0.28% aida04
Entry  Thu Jun 23 15:10:17 2022, Philippos Papadakis, Thursday 23 June 16:00-24:00 15x
16:20
System wide checks.
Clock status OK
White Rabbit Error status:
		 Base 		Current 	Difference
aida07 fault 	 0xc4fe : 	 0xc525 : 	 39  
aida08 fault 	 0xf0e9 : 	 0xf166 : 	 125  
White Rabbit error counter test result: Passed 6, Failed 2

FPGA error status:
                 Base 		Current 		Difference
aida07 fault 	 0x11 : 	 0x1c : 	 11  
aida08 fault 	 0x1a : 	 0x23 : 	 9  

Temps OK (attachment 1), Stats OK (attachment 2), Bias and leakage OK (attachment 3)


18:05
System wide checks.
Clock status OK
White Rabbit Error status:
		 Base 		Current 	Difference
aida07 fault 	 0xc4fe : 	 0xc527 : 	 41  
aida08 fault 	 0xf0e9 : 	 0xf177 : 	 142  
White Rabbit error counter test result: Passed 6, Failed 2

FPGA error status:
		 Base 		Current 		Difference
aida07 fault 	 0x11 : 	 0x1c : 	 11  
aida08 fault 	 0x1a : 	 0x24 : 	 10  
FPGA Timestamp error counter test result: Passed 6, Failed 2

Temps OK (attachment 4), Stats OK (attachment 5), Bias and leakage OK (attachment 6)


20:22
System wide checks.
Clock status OK
White Rabbit Error status:
		 Base 		Current 	Difference
aida07 fault 	 0xc4fe : 	 0xc529 : 	 43  
aida08 fault 	 0xf0e9 : 	 0xf17f : 	 150  
White Rabbit error counter test result: Passed 6, Failed 2

FPGA error status:
		 Base 		Current 		Difference
aida07 fault 	 0x11 : 	 0x20 : 	 15  
aida08 fault 	 0x1a : 	 0x25 : 	 11  
FPGA Timestamp error counter test result: Passed 6, Failed 2

Temps OK (attachment 7), Stats OK (attachment 8), Bias and leakage OK (attachment 9)

21:56
System wide checks.
Clock status OK
White Rabbit Error status:
		 Base 		Current 	Difference
aida07 fault 	 0xc4fe : 	 0xc529 : 	 43  
aida08 fault 	 0xf0e9 : 	 0xf186 : 	 157  
White Rabbit error counter test result: Passed 6, Failed 2

FPGA error status:	
		 Base 		Current 		Difference
aida07 fault 	 0x11 : 	 0x21 : 	 16  
aida08 fault 	 0x1a : 	 0x26 : 	 12  

Temps OK (attachment 10), Stats OK (attachment 11), Bias and leakage OK (attachment 12)

23:50
System wide checks.
Clock status OK
White Rabbit Error status:
		 Base 		Current 	Difference
aida07 fault 	 0xc4fe : 	 0xc52e : 	 48  
aida08 fault 	 0xf0e9 : 	 0xf18c : 	 163  
White Rabbit error counter test result: Passed 6, Failed 2

FPGA error status:	
	
			 Base 		Current 		Difference
aida07 fault 	 0x11 : 	 0x21 : 	 16  
aida08 fault 	 0x1a : 	 0x27 : 	 13  
FPGA Timestamp error counter test result: Passed 6, Failed 2

Temps OK (attachment 13), Stats OK (attachment 14), Bias and leakage OK (attachment 15)
Entry  Thu Jun 23 06:56:02 2022, OH, Thursday 23 June 08:00-16:00 11x
07:56 Taken over from AM
      Current White Rabbit Error status:
      		 Base 		Current 	Difference
      aida07 fault 	 0xc4fe : 	 0xc51a : 	 28  
      aida08 fault 	 0xf0e9 : 	 0xf132 : 	 73  
      White Rabbit error counter test result: Passed 6, Failed 2

      FPGA error status:
      			 Base 		Current 		Difference
      aida07 fault 	 0x11 : 	 0x18 : 	 7  
      aida08 fault 	 0x1a : 	 0x20 : 	 6  
      FPGA Timestamp error counter test result: Passed 6, Failed 2

      Likely that at some point AIDA08 will drop out again. I think this occurs if there is a sudden burst of WR errors which causes the merger to drop the link

      Statistics ok - attachment 1
      FEE temperatures ok - attachment 2
      Bias and leakage currents ok - attachment 3
      Analysis of file R3_93 - attachment 4
      Still deadtime in aida02 of ~15%
      Patrick has said he will look into whether we are still sending info code 4 and 5 for every ADC event which could be contributing to the deadtime.
      
      Currently 2.2 TB of space on /media/SecondDrive
      Current data rate of 6.23MB/s
      At current data rate this should last 4 days

08:27 Currently no beam
      Problem with Alvarez 3 now
      Tomorrow will have a 1 hour break due to changing of the source

09:36 Beam back

09:59 System wide checks
		 Base 		Current 	Difference
      aida07 fault 	 0xc4fe : 	 0xc51b : 	 29  
      aida08 fault 	 0xf0e9 : 	 0xf138 : 	 79  
      White Rabbit error counter test result: Passed 6, Failed 2

      			 Base 		Current 		Difference
      aida07 fault 	 0x11 : 	 0x18 : 	 7  
      aida08 fault 	 0x1a : 	 0x20 : 	 6  

      Stats ok - attachment 5
      Temperatures ok - attachment 6
      Bias and leakage currents ok - attachment 7

11:14 FRS group is changing from Hg setting back to Pt

11:36 Back on Pt R3_129

14:14 Stats ok - attachment 8
      Temperature ok - attachment 9
      Bias and leakage currents ok - attachment 10
      System wide checks:
      WR:
      		 Base 		Current 	Difference
      aida07 fault 	 0xc4fe : 	 0xc523 : 	 37  
      aida08 fault 	 0xf0e9 : 	 0xf156 : 	 109  
      White Rabbit error counter test result: Passed 6, Failed 2

      FPGA
      	
			 Base 		Current 		Difference
      aida07 fault 	 0x11 : 	 0x1b : 	 10  
      aida08 fault 	 0x1a : 	 0x20 : 	 6

      Analysis of R3_156 - attachment 11  
Entry  Wed Jun 22 23:18:45 2022, AM, OH, TD, MA, Thursday 23 June 19x
00:00 TD Noticed on the last stats uploaded that AIDA08 had stopped sending signals.
      Attempted to recover restarting merger but this caused 01 to drop out.

00:10 DAQ recovered and AIDA01 recovered with a reboot


01:00 Attachments 1-4, white rabbit failures on aida07 and aida08, otherwise all good

03:00 Attachments 5-9, aida07 and aida08 failures on white rabbit and fpga timestamp, otherwise all good

05:00 Attachments 10-14, aida07 and aida08 failures on white rabbit and fpga timestamp continue, otherwise all good

07:00 Attachments 15-19, aida07 and aida08 failures on white rabbit and fpga timestamp continue, otherwise all good
Entry  Thu Apr 22 11:03:57 2021, JS, Thursday 22nd April: 12:00-16:00 12x
12:00 Taking over from Liam, all is well.

12:10 Beam dropped out for a minute, implantation rate is down a bit, peaking around 300 Hz

12:19 Beam stopped (from GSI log "Run stopped because of a call from HKR stating they have a problematic device which they 
need to check and will need apprx. 15 min.")

12:30
ucesb ok (no beam)
DB No faults
Stats ok.

12:34 In order to fix some ongoing FRS problem no beam expected for at least an hour.

13:00
We are taking intermittent beam while they work on the FRS

DB No faults
ucesb ok  elog:261/1
Current ok elog:261/2
Stats ok  elog:261/3
Temps ok elog:261/4

Clock status test result: Passed 12, Failed 0
Calibration test result: Passed 12, Failed 0
White Rabbit error counter test result: Passed 12, Failed 0

			 Base 		Current 		Difference
aida12 fault 	 0x0 : 	 0x46 : 	 70  
FPGA Timestamp error counter test result: Passed 11, Failed 1

Returned 0 0 0 0 0 0 0 0 0 0 0 0  
Mem(KB) :	4	8	16	32	64	128	256	512	1k	2k	4k
aida01 :     15      6      5      3      2      2      2      3      2      3      7   : 39580
aida02 :     21      7      4      2      2      3      2      3      2      3      7   : 39692
aida03 :     20     10      3      3      0      3      2      3      2      3      7   : 39600
aida04 :      8      7      4      5      2      4      3      2      2      3      7   : 39608
aida05 :     17     14      1      2      3      3      4      2      2      3      7   : 39748
aida06 :     17     10      2      3      2      2      4      2      2      3      7   : 39572
aida07 :     27     10      8      7      2      3      3      2      2      3      7   : 39708
aida08 :      9      6      2      3      2      1      3      3      2      3      7   : 39636
aida09 :      1      2      1      4      0      3      3      2      2      3      7   : 39204
aida10 :      5      8      4      4      2      2      1      3      2      3      7   : 39316
aida11 :      6      4      5      3      2      3      2      2      2      3      7   : 39144
aida12 :     15      5      8      1      0      4      1      3      2      3      7   : 39428


13:32
ucesb ok
DB No faults
Stats ok

14:01
ucesb ok
DB No faults
Stats ok

14.30 analysis of file /TapeData/S460/R50_528 - attachment 5
      cat /var/log/messages | grep /MIDAS - attachments 6 & 7
      Grafana DSSSD bias & leakage currents for last 7 days - attachment 8

14:55
DB No faults 
ucesb ok
Current ok elog:261/9
Stats ok  elog:261/10
Temps ok elog:261/11

FPGA Timestamp Check Error:
			 Base 		Current 		Difference
aida12 fault 	 0x0 : 	 0x4d : 	 77  
FPGA Timestamp error counter test result: Passed 11, Failed 1


15:30
ucesb ok
DB No faults
Stats ok

15:59
ucesb ok elog:261/12
DB No faults
Stats ok
Entry  Thu Apr 22 07:06:37 2021, LPG, Thursday 22nd April: 08:00-12:00 8x
08:01 - Taking over from Corrigan...

ucesb ok!
DB ok!
Stats ok!

08:30

ucesb ok!
DB ok!
Stats ok!

09:15

ucesb ok! elog:260/4
DB ok!
Stats ok!

Leakage currents ok! elog:260/1
Temperatures ok! elog:260/2
MIDAS Rates ok! elog:260/3

System wide checks
Clock ok!
ADC ok!
WR ok!
FPGA 1 fail
Base Current Difference
aida12 fault 0x0 : 0x40 : 64
FPGA Timestamp error counter test result: Passed 11, Failed 1
Memory ok!


09:45

ucesb ok!
DB ok!
Stats ok!

10:30

ucesb ok!
DB ok!
Stats ok!


11:00

ucesb ok! elog:260/5
DB ok!
Stats ok!

Leakage currents ok! elog:260/6
Temperatures ok! elog:260/7
MIDAS Rates ok! elog:260/8

System wide checks
Clock ok!
ADC ok!
WR ok!
FPGA 1 fail
Base Current Difference
aida12 fault 0x0 : 0x42 : 66
FPGA Timestamp error counter test result: Passed 11, Failed 1
Memory ok!


11:30

ucesb ok! elog:260/5
DB ok!
Stats ok!

11:55

ucesb ok!
DB ok!
Stats ok!
Entry  Thu Apr 22 15:18:20 2021, TD, Thursday 22 April 16.00-00.00 36x
16.20 zero all histograms, statistics & merger statistics

      most recent merger error messages

MERGE Data Link (29984): bad timestamp  6 3 0xc1ac7f1c 0x0dce7672 0x00002cda5dce7672 0x16782cda5dce7672 0x16782cda5dcf2032
MERGE Data Link (29984): bad timestamp  6 3 0xc18b7e62 0x0dce7e42 0x00002cda5dce7e42 0x16782cda5dce7e42 0x16782cda5dcf2032
MERGE Data Link (29984): bad timestamp  6 3 0xc1957ebc 0x0dce7e42 0x00002cda5dce7e42 0x16782cda5dce7e42 0x16782cda5dcf2032
MERGE Data Link (29984): bad timestamp  6 3 0xc1b67ecb 0x0dcf0ae2 0x00002cda5dcf0ae2 0x16782cda5dcf0ae2 0x16782cda5dcf2032
MERGE Data Link (29984): bad timestamp  6 3 0xc1957ea3 0x0dcf12b2 0x00002cda5dcf12b2 0x16782cda5dcf12b2 0x16782cda5dcf2032
MERGE Data Link (29984): bad timestamp  6 3 0xc1867fba 0x0b2ee142 0x00002dc9eb2ee142 0x16782dc9eb2ee142 0x16782dc9fad22532
MERGE Data Link (29984): bad timestamp  6 3 0x86800889 0x0ad28158 0x00002dc9eb2ee142 0x16782dc9ead28158 0x16782dc9fad22532
MERGE Data Link (29984): bad timestamp  6 3 0xc1be7e6e 0x0b2ef0e2 0x00002dc9eb2ef0e2 0x16782dc9eb2ef0e2 0x16782dc9fad2c172
MERGE Data Link (29984): bad timestamp  6 3 0xc1b08006 0x0b2f5e42 0x00002dc9eb2f5e42 0x16782dc9eb2f5e42 0x16782dc9fad34502
MERGE Data Link (29984): bad timestamp  6 3 0xc1807de7 0x0ad3c342 0x00002dc9eb2f6de2 0x16782dc9ead3c342 0x16782dc9fad34502
MERGE Statistics counters now cleared

16.21 merger server terminal reset & clear

      TapeData -> /media/ThirdDRive/TapeData

[npg@aidas-gsi bin64]$ df -h
Filesystem            Size  Used Avail Use% Mounted on
/dev/mapper/vg_aidasgsi-lv_root
                       50G   13G   34G  28% /
tmpfs                 7.9G  559M  7.3G   7% /dev/shm
/dev/sda2             477M   42M  410M  10% /boot
/dev/sda1             200M  264K  200M   1% /boot/efi
/dev/mapper/vg_aidasgsi-lv_home
                      401G   79G  302G  21% /home
/dev/mapper/vg_aidas2-lv_home
                      7.2T  3.9T  2.9T  58% /media/1e121361-83d3-4825-b6ae-8700b07e0ca7
/dev/sdd1             7.2T  6.3T  605G  92% /media/SecondDrive
/dev/sdc1             7.2T  3.6T  3.3T  52% /media/ThirdDrive

      at current rate (10.5Mb/s) we have 3.6d remaining 
      
17.40 *all* system wide checks OK *except* FPGA timestamp errors

		 Base 		Current 		Difference
aida12 fault 	 0x0 : 	 0x51 : 	 81  
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last


 Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same

 FEE : aida01 =>   Options file size is 1026 	 Last changed Wed Apr 21 01:51:54 CEST 2021
 FEE : aida02 =>   Options file size is 1014 	 Last changed Fri Apr 16 00:56:20 CEST 2021
 FEE : aida03 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida04 =>   Options file size is 1025 	 Last changed Sat Apr 17 06:07:36 CEST 2021
 FEE : aida05 =>   Options file size is 1025 	 Last changed Fri Apr 16 00:53:25 CEST 2021
 FEE : aida06 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida07 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida08 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida09 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:05 CEST 2021
 FEE : aida10 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:06 CEST 2021
 FEE : aida11 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:05 CEST 2021
 FEE : aida12 =>   Options file size is 1025 	 Last changed Mon Apr 19 09:05:25 CEST 2021

17.43 FEE64 temps OK - attachment 1
      statistics - attachments 2-8
      per FEE64 rate spectra - attachments 9 & 10
      1.8.L spectra - attachments 11-14
      1.8.H spectra - attachments 15-16
      1.8.W spectra 20us FSR - attachments 17-18
      1.8.W spectra 200us, 2ms & 20ms FSR - attachments 19-21, 30-32
      merger, tape server & merger statistics 19-25
      ucesb - attachment 26
      Grafana DSSD biases & leakage currents - attachment 27
      taperserver & tapeserver/merger server terminals - no timewarp errors since c. 15.25 - attachment 28
      DSSSD biases & leakage currents - attachment 29


22.17 *all* system wide checks OK *except*

		 Base 		Current 	Difference
aida01 fault 	 0x3612 : 	 0x3613 : 	 1  
aida02 fault 	 0x523c : 	 0x523d : 	 1  
aida03 fault 	 0xc5cd : 	 0xc5ce : 	 1  
aida04 fault 	 0x14f1 : 	 0x14f2 : 	 1  
aida05 fault 	 0x9a4e : 	 0x9a4f : 	 1  
aida06 fault 	 0xfdd2 : 	 0xfdd3 : 	 1  
aida07 fault 	 0x4a0 : 	 0x4a1 : 	 1  
aida08 fault 	 0xc796 : 	 0xc797 : 	 1  
White Rabbit error counter test result: Passed 4, Failed 8

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

			 Base 		Current 		Difference
aida12 fault 	 0x0 : 	 0x57 : 	 87  
FPGA Timestamp error counter test result: Passed 11, Failed 1
If any of these counts are reported as in error
The ASIC readout system has detected a timeslip.
That is the timestamp read from the time FIFO is not younger than the last

 Collecting the file size of each FEE64 Options CONTENTS file to check they are all the same

 FEE : aida01 =>   Options file size is 1026 	 Last changed Wed Apr 21 01:51:54 CEST 2021
 FEE : aida02 =>   Options file size is 1014 	 Last changed Fri Apr 16 00:56:20 CEST 2021
 FEE : aida03 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida04 =>   Options file size is 1025 	 Last changed Sat Apr 17 06:07:36 CEST 2021
 FEE : aida05 =>   Options file size is 1025 	 Last changed Fri Apr 16 00:53:25 CEST 2021
 FEE : aida06 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida07 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida08 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:04 CEST 2021
 FEE : aida09 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:05 CEST 2021
 FEE : aida10 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:06 CEST 2021
 FEE : aida11 =>   Options file size is 1014 	 Last changed Wed Apr 14 21:52:05 CEST 2021
 FEE : aida12 =>   Options file size is 1025 	 Last changed Mon Apr 19 09:05:25 CEST 2021

Most recent merger errors

MERGE Data Link (29979): bad timestamp  1 3 0xc05080ef 0x0c88aaa2 0x000047aa2c88aaa2 0x167847aa2c88aaa2 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc06f80d7 0x0c88aaa2 0x000047aa2c88aaa2 0x167847aa2c88aaa2 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc0778222 0x0c88b272 0x000047aa2c88b272 0x167847aa2c88b272 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc0598098 0x0c88e152 0x000047aa2c88e152 0x167847aa2c88e152 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc042815b 0x0c894eb2 0x000047aa2c894eb2 0x167847aa2c894eb2 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc05980eb 0x0c899502 0x000047aa2c899502 0x167847aa2c899502 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc075813c 0x0c89e322 0x000047aa2c89e322 0x167847aa2c89e322 0x167847aa2c8a34d2
MERGE Data Link (29979): bad timestamp  1 3 0xc04280d5 0x0c89f2c2 0x000047aa2c89f2c2 0x167847aa2c89f2c2 0x167847aa2c8a34d2
MERGE Actor (29995): Working with 0 from 12 data sources
MERGE Actor (29995): Working with 0 from 12 data sources

22.20 DSSSD biases & leakage currents - attachment 33
      FEE64 temps OK - attachment 34
      statistics - attachments 35
      merger statistics 36

      
Entry  Thu Sep 20 08:57:48 2018, OH, Thursday 20th September 180920_0958_Temp.png180920_1007_Stats.png180920_1042_LowEPulser.png180920_1117_HighEPulser.png
09:57 Alpha run stoppped R2_0 -> R2_2

      Thresholds dropped from 0x64 to 0xa
      Pulser turned on again
      System wide checks ok
      FEE Temp ok - attachment 1
      Bias ok, leakage at 1.485uA at 160V
      Stats in similar place to yesterday - attachment 2

      Low Energy pulser walkthrough
      1.0V to 0.4V in 0.1V steps
      2 minutes per step
      Pulser at 50Hz
10:29 Run started R3_0

10:45 Run stopped R3_2
      1.8.L spectra for low energy pulser walkthrough - attachment 3

11:00
 High Energy pulser walkthrough
      1.8V to 0.V in 0.2V
      2 minutes per step
      Pulser at 50Hz

11:06 Run started R4_0

10:18 Run stopped R4_2
      1.8.L spectra for high energy pulser walkthrough - attachment 4
Entry  Thu May 20 14:56:33 2021, OH, Thursday 20th May 16:00 - 24:00 10x
16:00 p+n threshold 0xc (120keV)
      n+n threshold DSSD2 0x20 (250keV) ASICS 1-3, 0x64 ASIC4
      n+n threshold DSSD2 0x19 (250keV) ASICS 1-3, 0x64 ASIC4

      Dead time has increased from yesterday. From the elog this appears to coincide with their changing of the spill structure.

17:30 Grafana informs us we have hit 10uA on DSSD2. This is fine with the size of the detector

18:12 Gregor noticed that at 18:02 the rate in AIDA increased. This could be related to the autofill starting around now.
      The deadtimes in FEE6 and 8 have risen to around 6.25%.
      Looking at this mornings and yesterday evenings fill times this behavior isn't observed

18:30 The rates still seem to be increased so is unlikely to be due to the filling which finished at least 10 minutes ago

18:49 Have tried raising the thresholds to 0x1a for the y side strips of DSSD2
      This has brought the deadtime of AIDA06 down to 5.53% (This seems to have just been a statistical fluctuation and the rate went back up again in the next file)

18:12 Raised threshold to 0x1b for ASIC1-3 of FEE6 and 8

18:15 System wide checks ok except WR as usual
	
		 Base 		Current 	Difference
aida05 fault 	 0x500 : 	 0x56d : 	 109  
White Rabbit error counter test result: Passed 15, Failed 1

Understand the status reports as follows:-
Status bit 3 : White Rabbit decoder detected an error in the received data
Status bit 2 : Firmware registered WR error, no reload of Timestamp
Status bit 0 : White Rabbit decoder reports uncertain of Timestamp information from WR

      Statistics increased at 18:02 still working on - attachment 2
      FEE temp - attachment 3
      Bias and leakage current - attachment 4


20:51 System wide checks ok - WR same as before
      Statistics still high - attachment 5
      Temperatures ok - attachment 6
      Bias and leakage currents ok - attachment 7 

22:52 Statistics still high - attachment 8
      Temp ok - attachment 9
      Bias and leakage current ok - attachment 10
      System wide checks ok - WR difference still 109
Entry  Thu May 2 00:16:22 2024, TD, NH, Thursday 2 May Screenshot_from_2024-05-02_13-21-07.pngScreenshot_from_2024-05-02_13-22-16.pngScreenshot_from_2024-05-02_13-22-43.png
01.15 FEE64 temperatures OK
      ADC data item stats
       aida02 & aida04 no data
       6/16 < 20k


10.25 FEE64 temperatures OK
      ADC data item stats
       aida02 & aida04 restarted
       7/16 < 20k, max 220k aida16

      all histograms zero'd

13.20 per p+n FEE64 1.8.L spectra - attachment 1
       aida09 pulser peak width 59 ch FWHM
      FEE64 temperatures OK
      ADC data item stats
       aida04 no data
       5/16 < 20k, max 332k aida08 

14.37
  Moved Time Machine delayed scaler from aida04 to aida07
  aida04 no data
  Reset merger etc 
  aida05 no data
  Reset merger etc 
  All FEEs with data again

  S4 Ambient Environment: 26.6 C / 30.4% RH / Td=7.8 C

17.26 FEE64 temperatures OK
      ADC data item stats OK

19.28 FEE64 temperatures OK
      ADC data item stats 
       aida02 no data - DAQ reset
      
Entry  Thu May 19 17:00:46 2022, TD, Thursday 19 May  Screenshot_from_2022-05-19_17-59-41.pngScreenshot_from_2022-05-19_17-58-21.pngScreenshot_from_2022-05-19_17-58-52.pngScreenshot_from_2022-05-19_17-59-20.png
18.01 DAQ stopped

Attachment 1 - grafana DSSSD bias, leakage current & temp - OK

Attachment 2 - DSSSD bias & leakage current

Attachment 3 - FEE64 temps - OK

Attachment 4 - ADC data item stats
Entry  Thu Mar 18 11:53:10 2021, TD, Thursday 18 March 7x
12.40 The snout w/bPlast plus 3xDSSSDs was removed yesterday

      AIDA pulser tests via adaptor PCB test inputs, i.e. zero capacitative load and zero leakage current

      per FEE64 1.8.W spectra - attachments 1-4
      per FEE64 Rate spectra - attachment 5
      per FEE64 1.8.L spectra - attachments 6-7 

From the per FEE64 1.8.L

FEE64 FWHM

1  -
2  45
3  25
4  -
5  -
6  45
7  25
8  37
9  30
10 38
11 19
12 35

For comparison we would expect to obtain ~ 15-20 ch FWHM (~10.5-14 keV FWHM) based on tests
conducted at T9, STFC DL. The peak widths observed above are significantly worse than expected.
Are the adaptor PCBs currently grounded to FEE64 Cu mezzanine cover?
Entry  Thu Apr 18 08:57:48 2024, JB, TD, Thursday 18 April 36x
09.52 DAQ continues file S100_alpha/R5
       note merger not functioning correctly due to aida03, aida04 & aida09 out of WR sequence 

      DSSSD bias & leakage current OK - attachment 1

      FEE64 temps OK - attachment 2
      *except* aida02 ASIC temp which is known to be u/s

      WR timestamps - attachment 3
       aida03, aida04 & aida09 out of sequence

      All system wide checks OK *except* ADC calibratio/FPGA/WR decoder status - attachments 4-6

      ADC data item stats - attachment 7

      per FEE64 Stat spectra - attachment 8

      per FEE64 1.8.L spectra - attachments 9-10

      per FEE64 1.8.W spectra - 20us FSR - attachments 11-12

      Merger, TapeServer & Link Data Rates - attachments 13-15

      Grafana - attachment 16
       DSSSD bias/leakage current trends OK


19.15 alpha background file S100_alpha/R10

      DSSSD bias & leakage current OK - attachment 17

      FEE64 temps OK - attachment 18
      *except* aida02 ASIC temp which is known to be u/s

      All system wide checks OK *except* ADC calibratio/FPGA/WR decoder status - attachments 19-21

      WR timestamps OK - attachment 22

      ADC data item stats - attachment 23

      Merger, TapeServer & Meger stats - attachments 24-26
       data rate c. 2.8Mb/s

      per FEE64 1.8.W spectra - 20us FSR - attachments 27-28

      correlation scaler stats & data link stats - attachments 29-30
       data rate dominated by MACB scaler inputs aida03 & aida04 ( c. 200kHz each )


22.16 DAQ continues Ok file S100_alpha/R10_35

      Merger, TapeServer & Meger stats - attachments 31-33
       data rate c. 2.8Mb/s

      ADC data item stats - attachment 34

      FEE64 temps OK - attachment 35
      *except* aida02 ASIC temp which is known to be u/s

      DSSSD bias & leakage current OK - attachment 36
ELOG V3.1.4-unknown