AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DESPEC, Page 30 of 33  ELOG logo
Entry  Thu Oct 31 16:43:03 2019, NH CA TD, Merger & MBS Performance MergerStats.pngMBSRates.pngMergernetworking.pngMergerStatistics.png
Testing merger with 3 DSSDs connected, with thresholds of 10 (slow comparator), 2 (HEC) and 255 (fast discriminator)

Merger handling rate of 1.6 million events per second comfortably. Forwarding to MBS fine.
Entry  Thu Oct 31 15:24:35 2019, TD, waveform spectra issues? 12x
 
Entry  Thu Oct 31 14:23:37 2019, TD, aida09 asic 1 no data readout? 10.png11.png12.png13.png
 
Entry  Thu Oct 31 10:33:34 2019, TD, [How To] Start TclHttpd server on Raspberry Pi 
1) Login to Raspberry Pi 

ssh pi@nnrpi2
Entry  Thu Oct 31 09:36:37 2019, TD, RIKEN LayOut directory LayOut.tar.gz
 
Entry  Thu Oct 31 09:00:58 2019, CA, TD, NH, Thursday 31 October 14x
10.05 DSSSD # 1-3 detector biases & leakage currents OK - see attachment 1
      Ambient temperature +21.2 deg C, d.p. +3.4 deg C, RH 31.2%
Entry  Wed Oct 30 11:51:08 2019, CA, TD, NH, Detector biasing bias30Oct.png30Octbias2.pnghvsketch.pdf
12.51 - detector bias and leakage currents - detector 3 has no current
                                           - other detectors ok
Entry  Wed Oct 30 08:06:49 2019, CA, TD, NH, DSSSD stack 6x
Ribbon cables fitted with kapton PCB couplers -> 3 isolated + 1 non-isolated for each cable length/DSSSD

Ribbon cable lengths:
Entry  Mon Oct 28 17:02:11 2019, TD, AIDA @ DESPEC cable length estimates 
AIDA snout length 37cm (from end of AIDA snout support assembly)

downstream scintillator (assembly depth 1cm)   36cm
Entry  Mon Sep 16 12:24:46 2019, NH, AIDA Monitoring 
https://docs.google.com/spreadsheets/d/1fZBybHodSvacUdKpDM_VKznqTrh49CKnqKVQVMEDWGs/edit?usp=sharing

A spreadsheet of ambient conditions and water temperature in S4 for AIDA.
Will show the distance to danger points (interlock shutdown and condensation on the pipes)
Entry  Fri Aug 16 15:09:05 2019, NH, Aida Waves (All FEEs) 12x
Included waves for all 12 FEEs

FEES 1, 5, 9 all show this HF noise on it, and are all located at the top of the AIDA mount.
Connections: HV from DSSD (-ve) is in FEE9
Entry  Thu Aug 15 14:09:39 2019, NH, AIDA Waveforms 10x
Noise seemed less strong today, unsure of cause. I had re-taped snout as tape was not sticking well.

Figures 1-4: Waves for all 4 FEEs connected to the DSSD
Figures 5-8: Zoomed in on region 400-600
Entry  Wed Aug 14 14:40:18 2019, NH, High Frequency Noise in AIDA HF.pngHFZ.png
Figures of intense high frequency noise pickup in AIDA.

Will investigate source in S4.

Edit: Period is approx 40 cycles / approx 2.5 MHz (?)
Entry  Mon May 20 13:33:06 2019, NH, New Merger/MBS Test Runs 8x
New merger has been worked on by VP which fixes the timewarp issues and MBS integration.

Currently no WAVE capture is supported, VP will re-add WAVE histogramming for startup testing.

10.05.2019 - Pulser walkthrough
    Reply  Tue Aug 13 13:55:45 2019, NH, New Merger/MBS Test Runs 6x
AIDA Finally working again so can test VP's added WAVE histogramming mode.

Fig 1. Waveforms for FEE12 ASIC 1. Sample rate = 10, Threshold = 10500
n.b. lots of "blank" wave channels for unknown reason, all low-energy channels show pulser so it's not a DSSD signal problem?
Entry  Tue Aug 13 09:17:02 2019, NH, AIDA 12/08/2019 AIDATemps-1208191457.png
The other 6 FEEs were powered on one at a time to check no issues. None found.
All 12 FEEs plugged back into the PSU.

Note: The FEE temperatures reported on Friday were before a Reset/Setup of the DAQ, which means the ASICs run very fast and the hence run hotter.
Entry  Fri Aug 9 12:33:14 2019, NH, Aida Test 9/8/19 - FEES 1-6 
The water issue has been resolved - merely incorrect temperature guages (replaced). Water is 20 C as required.

S4 conditions at 13:12 CEST

26.5 C / 47.2 % / Td = 14.3 C
Entry  Mon Aug 5 12:57:48 2019, NH, S4 Conditions 
Temp: 26 C
Humidity: 50%
Dew Point: ~15 C
Entry  Wed Jul 10 10:46:05 2019, NH, AIDA/Water 10.07.2019 
S4 Conditions:

25.2 C, 35.3% RH, Td = 8.8 C

Water temperature: 20 C
Entry  Fri Jun 28 15:05:49 2019, NH, Aida 28/6/2019 - WATER OFF 
The humidity sensor hasn't reported humdities under 90% yet. In order to try and help dry the pipes and turn AIDA the water has been turned off the
weekend.
Sunday temperatures might reach 40 C which means it may struggle anyway.
    Reply  Mon Jul 8 16:02:52 2019, NH, PJCS, Aida 28/6/2019 - WATER OFF 
It occurs to to wonder if there is now water inside the modules. If the metal of the cooling plates is damp on the outside then it is safe to assume
there is water on the inside too . Can I suggest that one  of the modules is dismounted, disassembled and checked?

Patrick
Entry  Mon Jul 1 09:42:16 2019, NH, AIDA - 01/07/2019 
Water is still off.

Checked dewpoint sensor still flashing red light (indicating an error). Pipes warmed. Not what I expected. Possible fault?

I checked S4's ambient temp/humidity with a home-brought sensor: Reports 27 C/50% RH (Dew Point = 16 C)
ELOG V3.1.4-unknown