AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  CARME, Page 27 of 28  ELOG logo
ID Date Authordown Subject Text Attachments
  89   Mon Sep 27 21:33:50 2021 CB (remotely)CARME baking status -7Current temperature ~87 C, increasing
See plot and screen attached.
Thermocouple on CARME foot side (1-4) may
 Temps.pngScreen.png 
  100   Fri Oct 1 21:47:51 2021 CB (remotely)CARME baking status -16Current temperature ~132 C (on manual mode
RE72-1: 132 C, RE72-2: 130 C)
See plot and screen attached.
 screen.pngTemps.png 
  164   Sun Nov 28 15:57:45 2021 CB (remotely)Nov 2021 temperaturesAttached  211128164424_temperatures.zip 
  166   Tue Dec 7 09:39:59 2021 CB (remotely)Gate valves closedDry run complete.

YR09 section valves closed. Section
isolated. Manual valve between electron target
  
  49   Tue Aug 31 18:56:35 2021 CBCARME status(ELOG does not allow more pictures to be added
to previous entry)
 9x 
  115   Sat Oct 9 09:47:33 2021 CBTo do list for next week0. Give split-funnels to OG or Grossmontage
to clean. Mount back foot support for gate
valves. Critical when we split.
 Capture.PNG 
  194   Mon Feb 14 09:56:39 2022 CBShifters instructions 2022EMERGENCY SHUTDOWNS

1. CARME motors: Q key
on keyboard while on workspace 1 of appc218
 10x 
  236   Tue Feb 22 12:23:23 2022 CBSlow comparator thresholds lowered - test run13:20 Stopped run.

Slow comp thresh 0x64 -> 0x32
on all FEEs
  
  282   Fri Feb 25 11:20:30 2022 CBPressure and temperature data savedSaved pressure reading and temperature
data logs from internal target in /TapeServer/22Feb/OtherData

Leakage current data is saved in
  
  437   Wed Aug 30 10:28:36 2023 CBPreparing for pumps onWe need to connect the non-bakeable (max
80C) wire of the ion pump belonging to the
vacuum division, and we also need to connect
  
  438   Thu Aug 31 08:36:34 2023 CBNEG activation Found CARME at 50C, a bit cooler than expected,
probably due to invasive tent changes yesterday
to mount missing wires. Increased heaters
  
  439   Fri Sep 1 08:11:40 2023 CBNEG activation - 29:10 Set heaters temperature 300 ->
250 C in preparation for cooling down and
to help keep DSSD temperature down. Started
  
  440   Sat Sep 2 10:04:55 2023 CBTurbo GV closed Found CARME in XHV at 1.1E-11 mbar. Chamber
temperature around 30C cooling slowly.

Closed GV to top turbo. Pressure
  
  453   Sun Oct 15 09:35:03 2023 CBStarting ramp down10:40 - Status as attached. Heaters setpoint/read
at 250 C, 150 C, 225 C. Power stable at 53%,
41%, 63%
 Screenshot_2023-10-15_10-35-47.pngScreenshot_2023-10-15_17-56-00.png 
  454   Mon Oct 16 08:28:02 2023 CBNEG activation -19:00 - Michael's online vacuum pressure
plot is no longer working - an old image
is being displayed. CARME temperatures around
 Screenshot_2023-10-16_17-17-30.png 
  455   Tue Oct 17 08:43:47 2023 CBNEG activation -209:40 - Found temperature and pressure
stablised, but too high to comfortably activate
NEGs closest to detectors. Detector temperature
 Screenshot_2023-10-17_09-45-23.pngScreenshot_2023-10-17_11-04-09.pngScreenshot_2023-10-17_14-56-55.pngScreenshot_2023-10-17_17-58-24.pngScreenshot_2023-10-17_17-58-51.png 
  495   Tue Feb 6 09:39:54 2024 CBDetector bias tests10:30 Found ADC#4 on aida 1 and 4 are suddenly
noisy. See attach 1-2. Checkloaded multiple
times - no effect.
 13x 
  527   Sun Feb 18 13:58:33 2024 AR, OF, JMRun 42 - cooled beam on targetRun 42 - 15:00

Detectors IN (left arm pot =36.54
mm, right arm pot = 70.49 mm). Stationary.
 27x 
  501   Fri Feb 9 07:57:38 2024 AR, CB, AB, JMRun10 - First cool beam on target8:58

System wide checks okay, except

   
 27x 
  380   Mon Nov 28 13:14:33 2022 AR TDMonday 28 November   12x 