Thu Oct 31 15:24:35 2019, TD, waveform spectra issues? 12x
|
|
Sat Apr 24 04:07:23 2021, ML, ucesb scalers
|
ucesb is back - see attachment |
Fri Apr 16 05:13:09 2021, ML, system wide checks 16x
|
system wide checks:
Done around 4am.
################################# |
Sun Apr 18 17:27:44 2021, ML-OH, system wide checks 17x
|
system wide checks at 6pm CET
##################################################
Difference noted from previous shift: |
Sun Apr 18 21:43:01 2021, ML-OH, system wide checks 20x
|
New System wide check 10pm CET
Clock status test result: Passed 12, Failed 0
Understand status as follows |
Sat Apr 24 01:44:09 2021, ML, system wide checks 7x
|
system wide checks:
|
Thu May 13 21:21:25 2021, Philippos and Marc, system wide checks 13x
|
Wide checks at Time 22:22 CET
Clock status test result: Passed 16, Failed 0
Understand status as follows |
Thu May 20 23:26:11 2021, Marc Labiche (ML), system wide checks 9x
|
System Wide check at begining of the night shift:
-----
Clock status test result: Passed 16, Failed 0 |
Fri May 21 02:17:47 2021, ML, system wide checks 9x
|
Wide check at 3am -
All fine.
Same output as at the beginning of the shift (see my previous entry) and attachments. |
Fri May 21 06:09:28 2021, ML, system wide checks 8x
|
System wide checks at 7am CET
All seems fine, nothing significant to report
Slight increase of dead time noted in FEE 3, 5 and 7. |
Wed Mar 11 16:29:17 2020, CA, LS, TD, slow comparator threshold comparison   
|
17.29 good event statistics for slow comparator threshold at 100 keV (0xa) - attachment 1
17.36 good event statistics for slow comparator threshold at 110 keV (0xb) - attachment 2
|
Wed Apr 3 15:24:06 2019, CA, TD, report - low inquire save state
|
On Save/Restore Module Settings Tab - "inquire save state" returns an error. See attachment 1. |
Wed Apr 3 13:29:20 2019, CA, CB, TD, report - high DAQ stall    
|
aida10 runs very fast for a period, then stops.
Have to restart Merger and TapeServer to get it running again.
|
Sat Apr 24 03:32:11 2021, ML, quick checks
|
Quick system checks after crash
Temperature ok.
Still cannot connect remotely to /ucesb with my gsi web login and password (?). |
Tue Jul 7 08:50:27 2020, NH, nnrpi2 does not boot
|
MIDAS was not working properly on nnrpi2 - power cycled. Now system does not boot properly, it gets stuck trying to login claiming "PAM critical error"
- probable file system corruption?
Will investigate if SD card can be checked and repaired |
Fri Apr 9 16:40:36 2021, NH, nnrpi1 Update
|
nnrpi1 is now back in S4 with a new SD card and new raspberry pi.
The freezing originally continued (it was the USB system failing) but was fixed with a change to /boot/cmdline.txt coherent_pool=4M
It seems the kernel update to fix one bug introduced another...
|
Tue Mar 30 13:21:50 2021, NH, nnrpi1 (tty logs)
|
We had issues with all TTYs reading out on nnrpi1, I have moved them from an apparently faulty USB hub to a new one.
Trying to reboot the pi to detect the new USB ports and it didn't recover from boot
Trying to repair SD card but I get a lot of errors on my laptop, indications are the SD card is completely dead
|
Tue Oct 6 15:48:06 2020, NH, nnrpi kernel update
|
FYI:
The SD card on nnrpi2 was full again causing issues, the log files in /var/log (kern.log & messages) were *huge* and filled with the same error many times |
Sun Jun 26 23:04:30 2022, Marc, new shift - Monday 27 June 0:00 to 8:00 12x
|
0:00 Experiment continues to run smoothly. AIDA DAQ has been rather stable. Leakage current has gone up for the past two days in both DSSDs (combination
of high-Z and high-intensity beam and external high temperature).
Stats & Temperatures (VIRTEX,PSU, ASICs) all ok. |
Fri May 13 02:28:36 2022, ML, beam dropped
|
We see less counts in AIDA implant DSSD1 (~1Hz) than at the beginning of the night shift (~10Hz).
This seems to be beam related as the count rates in DESPEC & FRS Scalers seems to have dropped too. |