AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  DESPEC, Page 25 of 36  ELOG logo
New entries since:Thu Jan 1 01:00:00 1970
  IDdown Date Author Subject Text Attachments
  227   Fri Apr 16 02:15:12 2021 NHImplants/PunchthroughRate with beam < 1000 Hz still

Not Uranium but some fragments possibly produced
 53_AM.png 
  225   Fri Apr 16 00:47:36 2021 OH-MLAIDA DAQ Reset1:18 (CET) No rate in AIDA 07.

Oscar did a AIDA DAQ reset and
a quick wide check.
  
  224   Thu Apr 15 22:38:18 2021 OHThursday 15th April - 16th April23:38 They are testing the finger detector
      It is a lot of U they are putting into
it which is passing through to AIDA ~3500Hz
  
  223   Thu Apr 15 13:28:07 2021 TDThursday 15 April
13.28 System wide checks
 19x 
  222   Thu Apr 15 12:23:22 2021 NHFast Discriminator MasksIt is possible to get good rates with the
fast discriminators with a few hot channels
mask in aida03 and aida10
 Image_Pasted_at_2021-4-14_18-57.png 
  221   Wed Apr 14 15:14:55 2021 PJCSNote WellPlease note that for the forseeable future
the system function in the menu on the System
Wide Checks browser page labelled as 
  
  220   Wed Apr 14 12:14:47 2021 PJCSCorrections and changes14/4/21 @12:00 UK time

Corrected the failure of FADC re-calibration
All modules. The problem was a missing >
  
  219   Wed Apr 14 09:55:12 2021 TDTuesday 13 April
Two further comments
  
  218   Tue Apr 13 16:49:41 2021 TDTuesday 13 April
Rename Options directory
 8x 
  217   Tue Apr 13 14:24:48 2021 TDS460 informationaida-gsi Anydesk 897170655

DESPEC remote working - https://sf.gsi.de/d/a4fb2134e06a450ca777/
  
  216   Mon Apr 12 18:36:31 2021 NH[HowTo] AIDA & MBSSome instructions on AIDA and MBS and troubleshooting
are available here
https://sf.gsi.de/lib/c9ba0b4c-26bc-43d0-9b49-213fc594610f/file/AIDA%20and%20MBS%20Tips%20and%20Troubleshooting.pdf
 AIDA_and_MBS_Tips_and_Troubleshooting.pdf 
  215   Mon Apr 12 16:49:40 2021 TDMonday 22 April - pulser walkthrough & alpha background16.54 Pulser walkthrough

      ASIC settings 2019Dec19-16.19.51
 6x 
  214   Sat Apr 10 12:15:54 2021 OH, TDSaturday 10 April12:37 DAQ found crashed. Had crashed at some
time following 7:50am following previous
statistics update
 16x 
  213   Fri Apr 9 16:45:29 2021 NH, HA. GA, GZ, OH, TDAIDA NoiseAIDA snout was reconnected and we saw originally
a very good reduction in noise from S452
(fig 1)
 6x 
  212   Fri Apr 9 16:40:36 2021 NHnnrpi1 Updatennrpi1 is now back in S4 with a new SD card
and new raspberry pi.
The freezing originally continued (it was
  
  211   Wed Mar 31 15:46:09 2021 PJCSHowTo : Synchronize the ASIC clocks.To Synchronize the FEE64 ASIC clocks to
rise at the same timestamp time use the System
function Synchronise the ASIC clocks
  
  210   Wed Mar 31 15:40:42 2021 PJCSCheck Options files function addedThere is a new operation available in the
System Functions menu in the System Wide
Checks page. ( The page needs to be reset
  
  209   Wed Mar 31 12:46:10 2021 PJCSHowTo : Calibrate the LMK3200 clock devicesHere is a document showing how and where
to calibrate the LMK3200 devices that lock
to the system clock and generate the clocks
 Calibrating_the_LMK3200_clock_devices_on_the_AIDA_FEE64.pdf 
  208   Tue Mar 30 13:21:50 2021 NHnnrpi1 (tty logs)We had issues with all TTYs reading out on
nnrpi1, I have moved them from an apparently
faulty USB hub to a new one.
  
  207   Thu Mar 25 18:04:51 2021 TDMSL type BB18(DS) 24cm x 8cm cabling & bias configuration   MSL_type_BB18(DS)_24cm_x_8cm_configuration.pdf 
ELOG V3.1.4-unknown