AIDA GELINA BRIKEN nToF CRIB ISOLDE CIRCE nTOFCapture DESPEC DTAS EDI_PSA 179Ta CARME StellarModelling DCF K40
  nToF, all entries  ELOG logo
ID Datedown Author Subject
  74   Tue Apr 16 12:24:01 2024 EmmanuelMWD amplitude (dE and E)
Attachment 1: 26Al_PDF.pdf
26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf 26Al_PDF.pdf
  73   Mon Mar 25 12:57:30 2024 ClwAdapters for ntof setup

10 new Adapters for lemo to bnc on my desk

Attachment 1: 20240325_125536.jpg
20240325_125536.jpg
Attachment 2: 20240325_125528.jpg
20240325_125528.jpg
  72   Thu Dec 7 09:48:23 2023 EmmanuelMWDdetector and User Input

MWDdetector and UserInput

Attachment 1: UserInput_Silicons.h
                                                 DETECTOR SPECIFIC PARAMETERS (Lines may be commented with '#' sign!)
===================================================================================================================================================================================================================================
DETECTOR   DETECTOR   DETECTOR STEP   TIMING    MIXED     EXPAND   SMOOTHING     TIME          G-FLASH    G-FLASH     G-FLASH    G-FLASH   BASELINE   BASELINE   AMPLITUDE   AMPLITUDE   AREA/AMP.   AREA/AMP.   SIGNAL WIDTH   SIGNAL WIDTH    NUMBER OF     PULSE SHAPE
  NAME      NUMBER     CLASS   SIZE   FILTER   POLARITY   PULSES    FILTER       LIMIT         OPTION    THRESHOLD   MIN_WIDTH   WINDOW     OPTION     FILTER     OPTION     THRESHOLD   LOW THR.    HIGH THR.     LOW THR.       HIGH THR.    PULSE SHAPES     ADDRESS
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
PKUP          0         PSA   350/6      0        0          3       100     100000              0         100.        1.         0          -1       300        0              100         0.0        2000              1            4000            0

#################################
#    MWD PARAMETERS V6.2    #
#    Date: 10-Aug-2023      #
#################################
#################################

#                             Threshold   Polarity  PoleZeroCorr    DeconWindow      AvergWin    MAWindows  gain/offset   Gamma_Threshold    Amp_Threshold    fixed Dead time(ns)  time_diff_baselne    tailtime      time_const

EDET         1         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         2         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         3         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         4         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         5         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         6         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         7         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         8         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         9         MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         10        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         11        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         12        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         13        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         14        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         15        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20
EDET         16        MWD      1600            -1         5E5           150              40      1 60         16.0/0.0        100                6500             550                    1500            2      20

EDET         17        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         18        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         19        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         20        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         21        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         22        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         23        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         24        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         25        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         26        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         27        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         28        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         29        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         30        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         31        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20
EDET         32        MWD      800             1         5E5           150             40      1 60         16.0/0.0        100                6800             550                    1500            2      20

DEED         1         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200            550                    1500            2      20
DEED         2         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         3         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         4         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         5         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         6         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         7         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         8         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         9         MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         10        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         11        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         12        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         13        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         14        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         15        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20
DEED         16        MWD       30             -1         5E5            150             40      1 51         1.0/0.0         100                200             550                    1500            2      20

Attachment 2: MWDdetector.cc
/*
 * $Id$
 *
 * Author:	Sarah-Jane Lonsdale
 * Date:	02-Dec-2015
 * Version:     5.1 (8-Aug-2017)
 * Update:	Claudia Lederer-Woods
 * Date:	31-May-2018
 * Version:     6.0 (31-May-2018)
 * Update:	Nikolay Sosnin
 * Date:	24-Nov-2022
 * Version:     6.1 (24-Nov-2022)
 */

#include <math.h>
#include <string.h>
#include <iostream>
#include <iomanip>
#include <cmath>
#include <fstream>
#include <sstream>
#include <algorithm>
#include <vector>
#include <TFile.h>
#include <TH1F.h>
#include <TString.h>

using namespace std;

#include "MWDdetector.h"

void FormatHist(TH1D* h, TString name, TString title, TString xtitle, TString ytitle, int color, int width, int marker_color, int marker_style);

bool MWDDetector::parseConfigLine(char* line, const char* settings_file)
{
	cout << "Config: " << line << endl;
	if (!Detector::parseConfigLine(line)) return false;

	// threshold
	char* pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid Threshold" << endl;
		return false;
	}
	threshold = atof(pch);

	// polarity
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid negative polarity" << endl;
		return false;
	}
	polarity = atoi(pch);
	if (polarity>=0)
		polarity = 1;
	else
		polarity = -1;

	// pole zero correction
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid pole zero correction" << endl;
		return false;
	}
	pz = atof(pch);

	// deconvolution window
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid deconvolution window" << endl;
		return false;
	}
	m = atoi(pch);

	// average window
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid average window" << endl;
		return false;
	}
	l = atoi(pch);

	// presample
	pch = strtok(NULL," "); //NS: 27.07.2023
	if (!pch) {
		cerr << "UserInput: Invalid presample" << endl;
		return false;
	}
	presample = atoi(pch);
	
	//averaging windows 2
	pch = strtok(NULL," "); //NS: 27.07.2023
	if (!pch) {
		cerr << "UserInput: Invalid presample" << endl;
		return false;
	}
	window = atoi(pch);

	// presample/averaging window 2
	/*if (!parse2real(&presample, &window)) {
		cerr << "UserInput: Invalid averager 1/2" << endl;
		return false;
	}*/

	// gain/offset
	if (!parse2real(&gain, &offset)) {
		cerr << "UserInput: Invalid gain/offset" << endl;
		return false;
	}

	// gamma flash search start
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid gamma_threshold" << endl;
		return false;
	}
	g_threshold = atoi(pch);

	// minimum amp_threshold
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid amp_threshold" << endl;
		return false;
	}
	amp_threshold = atoi(pch);

	// gamma flash primary (additional) offset
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: Invalid fixed Dead time(ns)" << endl;
		return false;
	}
	gamma_time_primary = atoi(pch);//SL 08/07/17

	// time different for baseline determination
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: time_diff_baselne" << endl;
		return false;
	}
	time_diff_baseline = atoi(pch);//SL 08/07/17

	// time after g flash which has undershoot
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: tailtime" << endl;
		return false;
	}
	tailtime = atoi(pch);//SL 08/07/17


	// Time constant
	pch = strtok(NULL," ");
	if (!pch) {
		cerr << "UserInput: time_const" << endl;
		return false;
	}
	time_const = atoi(pch);  // 28/08/23


	return true;
} // parseConfigLine

int MWDDetector::analysis(
				ntof::lib::ReaderStructEVEH& eveh,	// EVEH event information
				ntof::lib::ReaderStructMODH& modh,	// MODH header information
				ntof::lib::ReaderStructACQC& acqc,	// ACQC pulse record
				PulseVector*   pulsevec,		// vector of pulses
				int movie_number,
				bool html)				// I: movie number
{
	Detector::analysis(eveh, modh, acqc, pulsevec, movie_number, html);

	double rate = modh.getSampleRate();
	int NofPeaks = 0;
	TString name = modh.getDetectorType();
	
	//double g_threshold = 2000; //move to .h file                           //CHANGED
	double tdiffsig = gamma_time_primary; 
	double tdiffbase = time_diff_baseline; // consider moving to h file
	int aver = presample;             //
	//double tailtime = 100000;  // time up to which there is an undershoot after gflash

	double* x          = new double[length_of_movie];
	double* xsmooth    = new double[length_of_movie]; //13.3.18
	double* xsmooth_ma = new double[length_of_movie]; //NS 22.05.2023
	double* y          = new double[length_of_movie];
	double* z          = new double[length_of_movie];
	double* zdiff      = new double[length_of_movie]; //13.3.18
	double* mwd_m      = new double[length_of_movie];
	double* ma_l       = new double[length_of_movie];	// moving average array
	double* mwd_deriv  = new double[length_of_movie];	// mwd derivative

	double timeScale = 1000.0 / rate; // in ns/Sample

	for(int i = 0; i < length_of_movie; i++){
	
		x[i] = polarity * (acqc[i] * gain + offset);
		y[i] = z[i] = zdiff[i] = xsmooth[i] = 0.0;         //13.3.18
	}
                                                //CHANGED
	int startofevent = aver / 2;
	
	//Averaging preamplifier output
	for(int i = startofevent; i < length_of_movie; i++){
		
		xsmooth[i] = 0.;
		
		for(int j = -1 * (aver - 1) / 2; j <= (aver - 1) / 2; j++){
			
			xsmooth[i] += x[i + j];                         
		}
		
		xsmooth[i] /= aver;
	}

	//Extra moving average test
	//const double window = 39.;
	int startofevent2 = window / 2; //NS 22.05.2023
	
	for(int i = startofevent2; i < length_of_movie; i++){
		
		xsmooth_ma[i] = 0.;
		
		for(int j = -1 * (window - 1) / 2; j <= (window - 1) / 2; j++){
			
			xsmooth_ma[i] += xsmooth[i + j];                         
		}
		
		xsmooth_ma[i] /= window;
	}

	// Locating maximum and minimum of derivative
	if(verbose){cout << "Begin amplitude extraction." << endl;}

	// Parameters for semi-gauss discriminator
	//const double time_const = 0; // SL 12/08/16 Emmanuel
	const double pole_zero = 5.e5;
	double a0, a1, b1;

	b1 = exp(-1. / int(time_const));
	a0 = (1. + b1) / 2.0;
	a1 = -1. * (1. + b1) / 2.0;

	// Single pole high pass with pz correction
	for(int i = 1; i < length_of_movie; i++){
		
		//y[i] = b1 * y[i - 1] + a0 * xsmooth[i] + a1 * xsmooth[i - 1] + xsmooth[i - 1] / pole_zero;
		y[i] = b1 * y[i - 1] + a0 * xsmooth_ma[i] + a1 * xsmooth_ma[i - 1] + xsmooth_ma[i - 1] / pz;
	}

	// Single pole low pass filter
	for(int i = 1; i < length_of_movie; i++){
	
		z[i] = b1 * z[i - 1] + a0 * y[i];
	}

	// devirative of filters
	for(int i = 1; i < length_of_movie; i++){
	
		zdiff[i] = -1. * z[i - 1] + z[i];
	}

	//bool beamType = false;
	
	//if(eveh.getBeamType() != 1){beamType = true;}

	double twait = 16000.; // introduce different time window for baseline depending on ded or par CLW 31/05/18

	/*if(eveh.getBeamType() == 2){twait = 13000.;} // dedicated
	if(eveh.getBeamType() == 3){twait = 19000.;} // parasitic
	else{twait = 16000.;}*/     

	////////////////////////////////////////
	//          MWD and filtering         //
	////////////////////////////////////////

	// moving window deconvolution
	for(int i = startofevent + m; i < length_of_movie; i++){ // SL 10/08/16   // 13/03/18 MWD on smoothed 
	
		//double d_m  = xsmooth[i] - xsmooth[i - m];
	  double d_m  = xsmooth_ma[i] - xsmooth_ma[i - m];
		double ma_m = 0.;

		for(int j = (i - m); j < (i - 1); j++) {
		
			//ma_m += xsmooth[j];
			ma_m += xsmooth_ma[j];
		}

		mwd_m[i] = d_m + ma_m / pz;
	}

	// moving average
	//for(int i = l + m + gamma_flash; i < length_of_movie; i++){ // SL 10/08/16
	for(int i = l + m; i < length_of_movie; i++){ // NS 31.07.2023
		
		ma_l[i] = 0.;

... 285 more lines ...
  71   Mon Oct 2 08:53:06 2023 EmmanuelEmpty Frame

An empty frame (on the top) was placed on Friday night.

Attachment 1: Empty_Frame.jpeg
Empty_Frame.jpeg
  70   Thu Sep 28 15:32:16 2023 EmmanuelLiF sample in

We switched from 10B target (number 1) to LiF target (number 3). We planned to take this measurement for one day.

Attachment 1: 20230928_154334.jpg
20230928_154334.jpg
Attachment 2: 20230928_155923.jpg
20230928_155923.jpg
Attachment 3: 20230926_115053.jpg
20230926_115053.jpg
Attachment 4: 20230928_155747.jpg
20230928_155747.jpg
  69   Wed Sep 27 09:54:06 2023 Emmanuel10B sample in

We switched from Aluminium target to Boron Target (number 1) on Tuesday (26th of Sept.). The Aluminium target was placed in the material room by the RP. We will change to LiF (number 3) on Thursday (28th of Sept.)

Attachment 1: 20230926_113136.jpg
20230926_113136.jpg
Attachment 2: 20230926_113811.jpg
20230926_113811.jpg
Attachment 3: 20230926_115036.jpg
20230926_115036.jpg
Attachment 4: 20230926_115053.jpg
20230926_115053.jpg
Attachment 5: 20230926_111737.jpg
20230926_111737.jpg
  68   Tue Sep 5 16:09:45 2023 EmmanuelDrop in gain for DEED 14

Dear all,

There was an issue with one of the strips of the deltaE detector (DEED 14), for run216644. The gain dropped to almost a factor of 3. Find attached.

Somehow, it was fixed, but still lags, when compared to other strips of deltaE. This was tested for a more recent run, run216651. Find attached.

I also checked a bit older run (run216637) and they look similar.. Find attached. Maybe we should figure out if this will be a problem for the DEED14 strips.

 

NOTE: The plots have the run number at the top-center.

 

Emmanuel Odusina

 

 

Attachment 1: alndeed14.png
alndeed14.png
Attachment 2: alndeed14b.png
alndeed14b.png
Attachment 3: alndeed14old.png
alndeed14old.png
  67   Mon Aug 21 12:08:59 2023 TDRAL108 +/-15V PSU test - JCMB 21.8.23
PSU Calex

Setup, PSU and ac mains filter - attachments 1-3


DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 50mV/div x: 100ns, 200ns, 1us, 2us, 10us/div

Without ac mains filter - attachments 4-8



DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 10mV/div x: 100ns, 200ns, 1us, 2us, 10us/div

With ac mains filter - attachments 9-13

Conclusion - Claud Lyons Ltd STF Series Surge & Transient Power Filter produces c. x 2 attenuation of HF noise transients
Attachment 1: 20230821_115139.jpg
20230821_115139.jpg
Attachment 2: 20230821_115314.jpg
20230821_115314.jpg
Attachment 3: 20230821_115259.jpg
20230821_115259.jpg
Attachment 4: 20230821_115144.jpg
20230821_115144.jpg
Attachment 5: 20230821_115156.jpg
20230821_115156.jpg
Attachment 6: 20230821_115206.jpg
20230821_115206.jpg
Attachment 7: 20230821_115216.jpg
20230821_115216.jpg
Attachment 8: 20230821_115229.jpg
20230821_115229.jpg
Attachment 9: 20230821_115415.jpg
20230821_115415.jpg
Attachment 10: 20230821_115424.jpg
20230821_115424.jpg
Attachment 11: 20230821_115438.jpg
20230821_115438.jpg
Attachment 12: 20230821_115447.jpg
20230821_115447.jpg
Attachment 13: 20230821_115457.jpg
20230821_115457.jpg
  66   Sat Aug 19 14:14:26 2023 TDRAL108 +/-15V PSU test - JCMB 18.8.23
PSU Calex

Setup and PSU details - attachments 1-3

DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 20mV/div x: 100ns, 200ns, 1us, 2us, 10us, 20us & 100us/div - attachments 4-10
Attachment 1: 20230818_115256.jpg
20230818_115256.jpg
Attachment 2: 20230818_120358.jpg
20230818_120358.jpg
Attachment 3: 20230818_120127.jpg
20230818_120127.jpg
Attachment 4: 20230818_115311.jpg
20230818_115311.jpg
Attachment 5: 20230818_115329.jpg
20230818_115329.jpg
Attachment 6: 20230818_115250.jpg
20230818_115250.jpg
Attachment 7: 20230818_115421.jpg
20230818_115421.jpg
Attachment 8: 20230818_115341.jpg
20230818_115341.jpg
Attachment 9: 20230818_115409.jpg
20230818_115409.jpg
Attachment 10: 20230818_115352.jpg
20230818_115352.jpg
  65   Thu Aug 17 10:26:51 2023 Nikolay SosninData Processing

To run raw2root on LXPLUS, you will need to add the following line to your .bashrc, performed using

gedit ~/.bashrc &

then paste line at the bottome of the file

export LD_LIBRARY_PATH=$LD_LIBRARY_PATH:/afs/cern.ch/user/n/ntofuser/public

then save and close the gedit (a linux text editor similar to Windows Notepad). Text file .bashrc is responsible for setting correct paths to various system settings when you log in. The line above sets correct libraries for raw2root from the n_TOF official directories.

 

The old version of raw2root which I use is stored in a directory on EOS accessible via LXPLUS:

cd /eos/home-n/nsosnin/public/raw2root

If you examine the contents of the directory using command ls, there will be two folders: ntoflib and prg. The relative location of these folders on your system should always be the same, and you do not need to do anything in the ntoflib directory, so we can explore the next directory

cd prg && ls

Command cd means change directory and ls is list contents, double-& chains commands in a sequence. Your terminal should now display two more directories: detector and raw2root. detector is a list of codes for various detector types, examine its contents with ls detector. We use MWDdetector.cc and its library header file MWDdetector.h. All the filters are defined and can be changed in MWDdetector.cc, which is a C++ code. You can browse and change its contents with gedit. raw2root codes, however, are run from the raw2root directory, so let's change to it

cd raw2root && ls

When you list the contents of this directory there will be many files, none of which you need to edit. There will also be a directory called Traces, which I created as the default location for signal traces to be written, if relevant sections of MWDdetector.cc are uncommented (discussed below). If you are happy with the contents of MWDdetector.cc, you need to re-compile raw2root. Using C++ code, unlike some others, is a two-step process: compilation and execution. Various bits of code in raw2root and its libraries are put together into one executable file called raw2root during compilation stage, and then the code can be run by executing the executable. To compile raw2root, you need to be in its directory, which you can check by typing in

pwd

which should then display /eos/home-n/nsosnin/public/raw2root/prg/raw2root and if you it displays something else, use

cd /eos/home-n/nsosnin/public/raw2root/prg/raw2root

To compile raw2root in this directory use

make clean && make proper && make

The code will start compiling and do so for a while. It will display some warnings associated with other older n_TOF codes. There should, however, be no errors. If there are errors, something went wrong in MWDdetector.cc, so try troubleshooting it by Googling the errors (the line with the error will also display two numbers, something like error: MWDdetector.cc:1211:45, and the the second number is the line where the problem occurred). C++ errors are a dark art though, so feel free to contact me for help.

If the compilation displays no errors (woo!), the code compiled successfully. To test it, two things are needed: UserInput file and .raw.finished file. UserInput file called UserInput_Silicons.h, which I use, is already stored in that directory. If you examine it with gedit, you will see lines with detector names and numbers and the filtering parameters. The parameters are read in at the top of MWDdetector.cc in order, so you can follow the variables they are read into throughout the code to figure out which parameter does what (this is not an easy task!).

.raw.finished files are binary data files with detector signal traces, which raw2root filters and makes into ROOT files. These need to be downloaded from CERN servers (I left two example ones in the directory though). While the experiment is running these are stored, but will eventually be deleted, so if they don't download, contact me on staging data (i.e. writing it onto servers again after deletion). To download such a binary file for this experiment to the directory you are in use

xrdcp xroot://eosctapublicdisk.cern.ch//eos/ctapublicdisk/archive/ntof/2023/EAR2/26Al_DSSSD/216408/stream1/run216408_1_s1.raw.finished .

Here, xrdcp command is CERN's own copying command, which takes data from the directory listed in the command. I have highlighted above in yellow the bits you may need to change in the command. The first two are simply run number. The last one is the data segment. n_TOF data within a run are subdivided into 20 proton bunch segments, so one such .raw.finished file that you download contains 20 bunches (which is a very small amount of data, so if you need mass_processing, contact me or Fran (francisco.garcia.infantes@cern.ch) at n_TOF). You can download different segments by changing this number. Bunches 1-20 are in segment 0, bunches 21-40 in segment 1, etc.

Once you have downloaded the file of interest execute raw2root with command

./raw2root -p UserInput_Silicons.h -f run216408_1_s1.raw.finished -r rootout.root

This will run for some time, applying settings from UserInput to filters in MWDdetector.cc, and running the filters over data in the .raw.finished file. This will produce an output file called rootout.root, but feel free to change the name in the command to whatever you like, otherwise you will just keep overwriting the old files. This output file will have the amplitudes, times etc. of all the extracted signals listed, but it will not produce traces, as that is not standard raw2root functionality, and requires my code, which I added to MWDdetector.cc

To print traces, open MWDdetector.cc using

gedit ../detector/MWDdetector.cc &

Note, ".." on Linux means "previous directory", so the command above will leave raw2root directory, go to detector directory and open the code. In this code, uncomment (i.e. remove // or /* or */ characters in C++) from lines 310-312, 441, 442, 465 and 529. This will now print trace ROOT files into the Traces directory. Warning: this runs very slowly, as it's a lot of data being written to disk!

The if() statment on line 465 allows you to gate on specific bunches and detectors for producing traces. The contents of histograms inside the output files can be understood in terms of what MWDdetector.cc does by reading the lines 514-522 of that code. This should be everything you need to get started with processing traces and filtering outputs. Good luck!

  64   Tue Aug 15 11:41:27 2023 TD, NSMonday 14 August - vacuum chamber pressure
08.35 Vacuum chamber pressure OK - see attachment 1
Attachment 1: 20230814_083514.jpg
20230814_083514.jpg
  63   Tue Aug 15 10:17:39 2023 TD, NSRAL108 +/-15V PSU test at EAR2, n_TOF Monday 14 August
On the morning of Monday 14 August 2x RAL108 +/-15V PSUs were borrowed from the Edinburgh equipment in the ISOLDE hall to check whether the same transient 
noise is observed at the +/-15V PSU outputs.


PSU #2 Farnell MX2

Setup - attachment 1

DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 50mV/div x: 1us, 500ns, 250ns & 25us/div - attachments 2-5



PSU #1 Coutant HSC15-3.0

Setup - attachment 6

DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 50mV/div x: 25us/div - attachment 7


Conclusion

Observe same amplitude and HF structure with all 3x RAL108 +/-15V PSUs
Attachment 1: 20230814_083448.jpg
20230814_083448.jpg
Attachment 2: 20230814_083549.jpg
20230814_083549.jpg
Attachment 3: 20230814_083556.jpg
20230814_083556.jpg
Attachment 4: 20230814_083601.jpg
20230814_083601.jpg
Attachment 5: 20230814_083445.jpg
20230814_083445.jpg
Attachment 6: 20230814_083323.jpg
20230814_083323.jpg
Attachment 7: 20230814_083319.jpg
20230814_083319.jpg
  62   Mon Aug 14 11:00:13 2023 TDRAL108 +/-15V PSU test in ISOLDE hall
This morning 2x RAL108 +/-15V PSUs were borrowed from the Edinburgh equipment in the ISOLDE hall to check whether the same transient noise is observed at the +/-15V PSU 
outputs - this was confirmed. See https://elog.ph.ed.ac.uk/nToF/63

Following this test the same 2x RAL108 +/-15V PSUs were tested in the ISOLDE hall ( 19" rack adjacent to the HIE-ISOLDE GP scattering chamber ). 


PSU #1 Coutant HSC15-3.0

Setup and PSU details - attachments 1-4

DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 5mV/div x: 400ns, 4us & 40us/div - attachments 5-7


PSU #2 Farnell MX2

Setup and PSU details - attachments 8-10

DSO ch#1 +15V AC/1M, ch#2 -15V AC/1M - y: 5mV/div x: 400ns, 4us & 40us/div - attachments 11-13


Conclusion 

The noise of the 2x RAL108 +/-15V PSUs differed somewhat ( frequency and structure of HF transients ) from each other in the ISOLDE test.

Compared to the EAR2, n_TOF test the amplitudes were c. 10x smaller and the HF transient frequency and structure differed.

This appears to confirm that the primary problem is the ac mains power in EAR2, n_TOF - input and/or output filtering is required.
Attachment 1: 20230814_110402.jpg
20230814_110402.jpg
Attachment 2: 20230814_111029.jpg
20230814_111029.jpg
Attachment 3: 20230814_111128.jpg
20230814_111128.jpg
Attachment 4: 20230814_111216.jpg
20230814_111216.jpg
Attachment 5: 20230814_110410.jpg
20230814_110410.jpg
Attachment 6: 20230814_110424.jpg
20230814_110424.jpg
Attachment 7: 20230814_110516.jpg
20230814_110516.jpg
Attachment 8: 20230814_110053.jpg
20230814_110053.jpg
Attachment 9: 20230814_110723.jpg
20230814_110723.jpg
Attachment 10: 20230814_110738.jpg
20230814_110738.jpg
Attachment 11: 20230814_110158.jpg
20230814_110158.jpg
Attachment 12: 20230814_110142.jpg
20230814_110142.jpg
Attachment 13: 20230814_110105.jpg
20230814_110105.jpg
  61   Sat Aug 12 09:24:19 2023 Nikolay Sosnin26Al Protons

Here is a Google spreadsheet for counting protons for the runs:

https://docs.google.com/spreadsheets/d/1INX8G9GAu-M70SdZdz55qXnMZNXKXLW7xfFH-eaLuQw/edit?usp=sharing

  60   Fri Aug 11 16:50:58 2023 Nikolay SosninEDET24

After inserting aluminium target, previously-dead channel 24 on EDET was re-plugged into a 12-bit card SPD02872. It is the only EDET on 12-bit card, the rest are on 14-bit. From pulsers, there appears to be a 90 ns offset from this EDET to others, with EDET24 preceeding the rest. The last channel on 14-bit cards was broken, hence havng to use 12-bit.

Attachment 1: EDET24_Card.JPG
EDET24_Card.JPG
Attachment 2: EDET24_Cable.JPG
EDET24_Cable.JPG
  59   Fri Aug 11 13:16:56 2023 Nikolay SosninE Front Incorrect Cabling

E front 2x16-way to 1x34-way IDC cable from the Junction Box to the IDC-Lemo 00 adaptor was found to be inserted upside-down - the 16-way IDC connectors did not have polarisation keys - meaning the E detector p+n junction strip signals collected with 26Al for the first night are not working. Signals from the dE p+n junction strips and E n+n Ohmic strips will be OK. The mistake occurred at the conclusion of the noise tests yesterday - see https://elog.ph.ed.ac.uk/nToF/52

The 2x16-way to 1x34-way IDC cable without polarisation keys has now been replaced.

Run 216417 and onwards have correct cabling. For runs before that, E back and dE are still reliable.

  58   Fri Aug 11 13:06:54 2023 AnnieSignal Spreadsheet info

Spreadhseet made for shifters to manually enter that they have checked each signal and that they can see gamma-flashes. It is saved as "26Al_EAR2_Signal_Checks.ods", it is located on the second monitor on the right of the control room, next to the monitor used to see the beam intensity (same monitor used to see signals).

It will stay open throughout the campeign. Shifters have been told to check signals more than just the once to record that they're okay, and there is a comments box for shifters to add any comments/issues that arises after they have recorde that they have checked the signals at least once.

Attachment 1: IMG_2920.JPG
IMG_2920.JPG
Attachment 2: IMG_2921.JPG
IMG_2921.JPG
Attachment 3: IMG_2922.JPG
IMG_2922.JPG
  57   Fri Aug 11 10:12:02 2023 AnniePressure, voltage and current check
Attachment 1: IMG_2915.JPG
IMG_2915.JPG
Attachment 2: IMG_2916.JPG
IMG_2916.JPG
Attachment 3: IMG_2918.JPG
IMG_2918.JPG
  56   Fri Aug 11 10:02:08 2023 TD, NS, ARNoise
Check RAL108 +/-15V PSU

Measured output voltages +15.21V -15.18V - OK

Observe output voltages with DSO ( ch #1 AC/1M +15V, ch #2 AC/1M -15V ) - see attachments 1 & 2

What we should observe is c. 1mV rms ( white ) noise but we clearly observe similar noise transients ( c. 60us period with HF structure ) to those observed at RAL108 
outputs. The RAL108 preamplifier units do have RC filters on the +/-15V - typically c. 100 Ohm and 4.7uF. Some additional, inline filtering with a lower rolloff 
frequency may be required.

> 
> Observe c. 2mV p to p noise with DSO ( Z_in = 50 Ohm ) c. 60us period with HF structure. DSO connected to junction box via 34-way IDC - 16x Lemo-00 adaptor.
> 
> Origin of noise upstream of 4x34-way to 8x16-way Junction Box. Not microphonics from Edwards RV5 Rotary Pump.
> No change observed with simple ground connections between NIM bin/+/-15V PSU/Junction Box and MSL type W1 preamplifier units/vacuum chamber/support assembly.
> 
> 
> Estimate of electronic noise
> 
> Pulser BNC PB-5
> 
> Amplitude 0.5V
> Attenuation x1
> Decay time 1ms
> Frequency 50Hz
> 
> Preamplifier RAL108
> Output impedance 100 Ohm
> Sensitivity 20mV/MeV ( into high Z load ), 6.7mV/MeV ( into 50 Ohm load ) 
> 
> Amplifier EG&G Ortec 571
> Input terminated by 50 Ohm
> Gain x1 (internal) x 1.0 (fine gain) x 50 (coarse gain ) = 50
> Shaping time 0.5us
> 
> MCA Amptek 8000D
> Input FSR 10V
> 12 bit ADC
> 
> 
> Nominal gain = 6.7mV/MeV x 50 = 335mV/MeV
> 
> 12 bit ADC input FSR = 10V / 0.335V/MeV = 29.85MeV FSR or 7.3keV/channel
> 
> 
> dE p+n junction strip # 4 ( of 0-15 )
> 
> pulser peak centroid = 799.8 ch
> pulser peak width = 7.8 ch FWHM = 57 keV FWHM
> 
> 
> E p+n junction strip # 4 ( of 0-15 )
> 
> pulser peak centroid = 864.8ch
> pulser peak width = 3.5 ch FWHM = 26 keV FWHM
> 
> 
> E n+n Ohmic strip # 4 ( of 0-15 )
> 
> pulser peak centroid = 913.0 ch
> pulser peak width = 5.3 ch FWHM = 39 keV FWHM
> 
> 
> Noise estimates are probably accurate to c. 10% level.
Attachment 1: 20230811_104233.jpg
20230811_104233.jpg
Attachment 2: 20230811_104253.jpg
20230811_104253.jpg
  55   Fri Aug 11 09:17:28 2023 AnnieLi target scans

Processed scans of both sides of the Li target showing the beam spot, and an image showing what it looks like to the eye.

Attachment 1: 7Li_foil_side1_post_processed.pdf
7Li_foil_side1_post_processed.pdf 7Li_foil_side1_post_processed.pdf
Attachment 2: 7Li_foil_side2_post_processed.pdf
7Li_foil_side2_post_processed.pdf 7Li_foil_side2_post_processed.pdf
Attachment 3: IMG_2914.JPG
IMG_2914.JPG
  54   Fri Aug 11 09:11:04 2023 AnniePulse Settings
Attachment 1: IMG_2908.JPG
IMG_2908.JPG
Attachment 2: IMG_2909.JPG
IMG_2909.JPG
Attachment 3: IMG_2910.JPG
IMG_2910.JPG
Attachment 4: IMG_2911.JPG
IMG_2911.JPG
  53   Fri Aug 11 08:41:31 2023 AnnieAl target & chamber set up

Phtotos of the front & back of the Al target and what it looked like once mounted and in the chamber.

Attachment 1: IMG_2860.JPG
IMG_2860.JPG
Attachment 2: IMG_2862.JPG
IMG_2862.JPG
Attachment 3: IMG_2867.JPG
IMG_2867.JPG
Attachment 4: IMG_2868.JPG
IMG_2868.JPG
Attachment 5: IMG_2874.JPG
IMG_2874.JPG
Attachment 6: IMG_2875.JPG
IMG_2875.JPG
Attachment 7: IMG_2877.JPG
IMG_2877.JPG
Attachment 8: IMG_2879.JPG
IMG_2879.JPG
Attachment 9: IMG_2880.JPG
IMG_2880.JPG
Attachment 10: IMG_2882.JPG
IMG_2882.JPG
Attachment 11: IMG_2884.JPG
IMG_2884.JPG
Attachment 12: IMG_2896.JPG
IMG_2896.JPG
Attachment 13: IMG_2897.JPG
IMG_2897.JPG
Attachment 14: IMG_2903.JPG
IMG_2903.JPG
Attachment 15: Al26_Target_Above.JPG
Al26_Target_Above.JPG
  52   Thu Aug 10 16:11:57 2023 TD, NS, ARNoise
Observe c. 2mV p to p noise with DSO ( Z_in = 50 Ohm ) c. 60us period with HF structure. DSO connected to junction box via 34-way IDC - 16x Lemo-00 adaptor.

Origin of noise upstream of 4x34-way to 8x16-way Junction Box. Not microphonics from Edwards RV5 Rotary Pump.
No change observed with simple ground connections between NIM bin/+/-15V PSU/Junction Box and MSL type W1 preamplifier units/vacuum chamber/support assembly.


Estimate of electronic noise

Pulser BNC PB-5

Amplitude 0.5V
Attenuation x1
Decay time 1ms
Frequency 50Hz

Preamplifier RAL108
Output impedance 100 Ohm
Sensitivity 20mV/MeV ( into high Z load ), 6.7mV/MeV ( into 50 Ohm load ) 

Amplifier EG&G Ortec 571
Input terminated by 50 Ohm
Gain x1 (internal) x 1.0 (fine gain) x 50 (coarse gain ) = 50
Shaping time 0.5us

MCA Amptek 8000D
Input FSR 10V
12 bit ADC


Nominal gain = 6.7mV/MeV x 50 = 335mV/MeV

12 bit ADC input FSR = 10V / 0.335V/MeV = 29.85MeV FSR or 7.3keV/channel


dE p+n junction strip # 4 ( of 0-15 )

pulser peak centroid = 799.8 ch
pulser peak width = 7.8 ch FWHM = 57 keV FWHM


E p+n junction strip # 4 ( of 0-15 )

pulser peak centroid = 864.8ch
pulser peak width = 3.5 ch FWHM = 26 keV FWHM


E n+n Ohmic strip # 4 ( of 0-15 )

pulser peak centroid = 913.0 ch
pulser peak width = 5.3 ch FWHM = 39 keV FWHM


Noise estimates are probably accurate to c. 10% level.
Attachment 1: 20230810_162959.JPG
20230810_162959.JPG
Attachment 2: IMG_2906.jpeg
IMG_2906.jpeg
Attachment 3: 20230810_164219.JPG
20230810_164219.JPG
  51   Thu Aug 10 11:30:32 2023 Nikolay SosninSilicons and LiF3+Gafchromic Target
Attachment 1: EDET_150um_Box.JPG
EDET_150um_Box.JPG
Attachment 2: EDET_150um.JPG
EDET_150um.JPG
Attachment 3: EDET_ID.JPG
EDET_ID.JPG
Attachment 4: DEED_20um_Box.JPG
DEED_20um_Box.JPG
Attachment 5: LiF3_Gafchrmoic_Target_Mounted.JPG
LiF3_Gafchrmoic_Target_Mounted.JPG
Attachment 6: LiF3_Gafchromic_Side.JPG
LiF3_Gafchromic_Side.JPG
Attachment 7: LiF3_Gafchromic_Front.JPG
LiF3_Gafchromic_Front.JPG
Attachment 8: Detector_Mount_and_LiF3.JPG
Detector_Mount_and_LiF3.JPG
Attachment 9: Detectors_Mounting.JPG
Detectors_Mounting.JPG
Attachment 10: Detectors_Mounted_DEED.JPG
Detectors_Mounted_DEED.JPG
Attachment 11: Detectors_Mounted_EDET.JPG
Detectors_Mounted_EDET.JPG
Attachment 12: Detectors_and_LiF3_Gafchrmoic_TestPosition.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition.JPG
Attachment 13: Detectors_and_LiF3_Gafchrmoic_TestPosition_Back.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition_Back.JPG
Attachment 14: Detectors_and_LiF3_Gafchrmoic_TestPosition_Below.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition_Below.JPG
Attachment 15: Detectors_and_LiF3_Gafchrmoic_TestPosition_Above.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition_Above.JPG
Attachment 16: Detectors_and_LiF3_Gafchrmoic_TestPosition_Tilt.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition_Tilt.JPG
Attachment 17: Detectors_and_LiF3_Gafchrmoic_TestPosition_Front.JPG
Detectors_and_LiF3_Gafchrmoic_TestPosition_Front.JPG
Attachment 18: Assembly_Insert.JPG
Assembly_Insert.JPG
  50   Thu Aug 10 10:50:15 2023 Nikolay SosninAl26 Chamber Cabling/Vacuum/NIM
Attachment 1: Vacuum_Reading.JPG
Vacuum_Reading.JPG
Attachment 2: Pulser_Settings3.JPG
Pulser_Settings3.JPG
Attachment 3: Pulser_Settings2.JPG
Pulser_Settings2.JPG
Attachment 4: NIM_Bin.JPG
NIM_Bin.JPG
Attachment 5: Currents.JPG
Currents.JPG
Attachment 6: Amplifier_Settings.JPG
Amplifier_Settings.JPG
Attachment 7: HV_EDET.JPG
HV_EDET.JPG
Attachment 8: HV_DEED.JPG
HV_DEED.JPG
Attachment 9: Pulser_Settings1.JPG
Pulser_Settings1.JPG
Attachment 10: Cables_Full_View.JPG
Cables_Full_View.JPG
Attachment 11: Preamp_Cables.JPG
Preamp_Cables.JPG
Attachment 12: BNC_Converters.JPG
BNC_Converters.JPG
Attachment 13: DAQ_Cable_Connection_BNC.JPG
DAQ_Cable_Connection_BNC.JPG
Attachment 14: Ribbon_Cables_DAQ.JPG
Ribbon_Cables_DAQ.JPG
Attachment 15: Ribbon_Cables_DAQ.JPG
Ribbon_Cables_DAQ.JPG
Attachment 16: NIM_Setup_Full.JPG
NIM_Setup_Full.JPG
Attachment 17: Vacuum_Pump.JPG
Vacuum_Pump.JPG
Attachment 18: Vacuum_Pump_Exhaust.JPG
Vacuum_Pump_Exhaust.JPG
Attachment 19: Vacuum_Pump_Attachment.JPG
Vacuum_Pump_Attachment.JPG
Attachment 20: Vacuum_Gauge.JPG
Vacuum_Gauge.JPG
Attachment 21: Vacuum_Valve_Lid.JPG
Vacuum_Valve_Lid.JPG
Attachment 22: Ribbon_Cables_Back.JPG
Ribbon_Cables_Back.JPG
Attachment 23: Ribbon_Cables.JPG
Ribbon_Cables.JPG
  49   Thu Aug 10 10:05:48 2023 CLWGafchromics Foil

Gafchromics foil was mounted on empty brass frame back to back with Li sample

Neutron beam goes well through the sample. Centered ~1 cm from sample center. Conclusion: no changes needed (too risky to make it worse and it is ok now)

Attachment 1: 20230809_165433.jpg
20230809_165433.jpg
Attachment 2: 20230810_085457.jpg
20230810_085457.jpg
Attachment 3: 20230809_165436.jpg
20230809_165436.jpg
  48   Thu Aug 10 10:04:13 2023 CLWPhotos inside chamber Al26 run Aug2023
Attachment 1: 20230809_174847.jpg
20230809_174847.jpg
Attachment 2: 20230809_174905.jpg
20230809_174905.jpg
Attachment 3: 20230809_174943.jpg
20230809_174943.jpg
Attachment 4: Empty_Frame_Inside_Front.JPG
Empty_Frame_Inside_Front.JPG
Attachment 5: Empty_Frame_Inside_Sideview.JPG
Empty_Frame_Inside_Sideview.JPG
Attachment 6: Empty_Frame_Inside_Back.JPG
Empty_Frame_Inside_Back.JPG
Attachment 7: Assembly_Interior_Back.JPG
Assembly_Interior_Back.JPG
Attachment 8: Assembly_Interior_Front.JPG
Assembly_Interior_Front.JPG
  47   Thu Aug 10 09:55:50 2023 CLWPhotos of Chamber, Al26 Run Aug23
Attachment 1: 20230809_120302.jpg
20230809_120302.jpg
Attachment 2: 20230809_120309.jpg
20230809_120309.jpg
Attachment 3: 20230809_153802.jpg
20230809_153802.jpg
Attachment 4: 20230809_153809.jpg
20230809_153809.jpg
Attachment 5: 20230809_153821.jpg
20230809_153821.jpg
Attachment 6: Beamline_Chamber_Spacing.JPG
Beamline_Chamber_Spacing.JPG
Attachment 7: Assembled_Setup_Back.JPG
Assembled_Setup_Back.JPG
Attachment 8: Assembled_Setup_Back_Zoom.JPG
Assembled_Setup_Back_Zoom.JPG
Attachment 9: Final_Assembly_Front.JPG
Final_Assembly_Front.JPG
Attachment 10: Mounting_Bolts.JPG
Mounting_Bolts.JPG
Attachment 11: Mounting_Clamps.JPG
Mounting_Clamps.JPG
Attachment 12: EAR2_Pillars_Mount_Side.JPG
EAR2_Pillars_Mount_Side.JPG
Attachment 13: EAR2_Pillars_Mount_Front.JPG
EAR2_Pillars_Mount_Front.JPG
  46   Thu Aug 10 09:20:37 2023 CLWDetector Signal Cabling Al26 Aug 2023
delta E detector Cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 72 2204803 9 02911 DEED-1
1 73 2204804 10 02911 DEED-2
2 74 2204805 11 02911 DEED-3
3 75 2204806 12 02911 DEED-4
4 76 2204807 13 02914 DEED-5
5 77 2204808 14 02914 DEED-6
6 80 2204809 15 02914 DEED-7
7 81 2204810 16 02914 DEED-8
8 82 2204811 17 02917 DEED-9
9 85 2204812 18 02917 DEED-10
10 86 2204813 19 02917 DEED-11
11 87 2204814 20 02917 DEED-12
12 88 2204815 21 02916 DEED-13
13 90 2204816 22 02916 DEED-14
14 95 2204817 23 02916 DEED-15
15 96 2204818 24 02916 DEED-16
E p side cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 97 2204819 25 4683 EDET-1
1 101 2204820 26 4683 EDET-2
2 103 2204821 27 4683 EDET-3
3 104 2204822 28 4683 EDET-4
4 105 2204823 29 4684 EDET-5
5 106 2204824 30 4684 EDET-6
6 107 2204825 31 4684 EDET-7
7 108 2204826 32 4684 EDET-8
8 109 2204827 33 4682 EDET-9
9 110 2204828 34 4677 EDET-10
10 111 2204829 35 4682 EDET-11
11 112 2204830 36 4682 EDET-12
12 113 2204831 37 4697 EDET-13
13 114 2204832 38 4697 EDET-14
14 116 2204833 39 4697 EDET-15
15 117 2204834 40 4697 EDET-16
E n side cabling
Lemo Box Output Number Signal Cable Bunker Patch Panel Number Signal Cable Rack Area FADC Number DAQ Channel
0 118 2204835 41 5348? EDET-17
1 119 2204836 42 5348? EDET-18
2 120 2204837 43 5348? EDET-19
3 121 2204838 44 5348? EDET-20
4 123 2204839 45 4677 EDET-21
5 124 2204840 46 4677 EDET-22
6 125 2204841 47 4677 EDET-23
7 126 2204842 48 2872 EDET-24
8 127 2204843 49 4636 EDET-25
9 128 2204844 50 4636 EDET-26
10 129 2204845 51 4636 EDET-27
11 130 2204846 52 4636 EDET-28
12 131 2204847 53 4674 EDET-29
13 132 2204848 54 4674 EDET-30
14 133 2204849 55 4674 EDET-31
15 134 2204850 56 4674 EDET-32

 

Attachment 1: 20230809_120804.jpg
20230809_120804.jpg
Attachment 2: 20230809_121357.jpg
20230809_121357.jpg
Attachment 3: 20230809_153703.jpg
20230809_153703.jpg
Attachment 4: 20230809_153720.jpg
20230809_153720.jpg
Attachment 5: 20230809_153730.jpg
20230809_153730.jpg
Attachment 6: 20230809_153744.jpg
20230809_153744.jpg
Attachment 7: 20230809_192718.jpg
20230809_192718.jpg
Attachment 8: 20230810_090445.jpg
20230810_090445.jpg
  45   Thu Aug 10 09:10:02 2023 CLWDetector Setup Al26 Run 2023

dE Detector: W1-20 3186-9 20 um

E Detector: W1-150 3458-4 144 um

Voltages and Leakage Currents:

dE: 6 V, 0.02 muA

E: 50 V, 0.05 muA

Attachment 1: 20230809_181749.jpg
20230809_181749.jpg
Attachment 2: 20230809_181758.jpg
20230809_181758.jpg
Attachment 3: 20230809_172545.jpg
20230809_172545.jpg
Attachment 4: 20230809_172442.jpg
20230809_172442.jpg
  44   Mon Jul 31 10:21:41 2023 Nikolay Sosninn_TOF Data and Filtering
Attachment 1: Al26_Filtering.pptx
  43   Thu Jul 27 11:53:52 2023 TDMSL type W1 detector data for 26Al(n,X) experiment EAR2, n_TOF
MSL type W1(SS)-20

3186-9  20um Depletion voltage 3V Operating voltage 6V
3585-12 20um Depletion voltage 2V Operating voltage 4V

MSL type W1(DS)-150

3458-1 157um Depletion voltage 22V Operating voltage 52V
3458-4 144um Depletion voltage 18V Operating voltage 48V
  42   Thu Jul 27 11:25:35 2023 ClaudiaAl-26 planning meeting summary
  • Start 9th August, access to EAR-2 11 am earliest but can start in rack area before
  • Setup to be used: 1 dE (16 strips, 20 um thickness) + 1 E (16x16 strips, 150 um thickness. We have a spare for each thickness
  • Sample and detectors to be mounted on the same flange

Things to check:

  • alignment with beam centre (lasers and/or gafchromics foils)
  • is the setup stable to knockes, can all detector / sample positions be well reproduced when making changes

Once setup us completed:

  • checks with pulser
  • mounf LiF sample number 3 and run with neutron beam
  • check that all strips have signals
  • confirm shape of gamma flash and that short times can be anaysed in both detectors (~1.8 us after flash)

If everything working:

  • measure LiF-3 and the switch to Al-26
  • towards end of the run we can also measure B-3 and the empty brass frame (Frame without mylar)
  • proton statistics: 1E17 LiF-3, 1F17 B-3, ~3E17 Empty, 5.5 E18 Al-26

Travel times

Nick: 8-16, Annie 8-12, Tom, 7 -?, Claudia, 8-10, Emmanuel asap until end of run

Measurement runs until Octover 2nd. Disassembly by Nick and Emmanuel.

additional trips during the measurement as required (if something breaks/fails etc. )

 

Attached: photos of previous setup

 

TO Do: MCA availability at nTOF for quick noise checks (Nick)

            how many  channels in 14 bit, how many 12 bit (Nick)

          depletion voltages   for detectors (Tom)

          Register the eqipment at CERN as Edinburgh property (Claudia)

 

 

Attachment 1: DSC00366.JPG
DSC00366.JPG
Attachment 2: DSC00346.JPG
DSC00346.JPG
  41   Mon Jul 3 13:01:30 2023 EmmanuelBoxes for nTOF experiments to CERN

Box 1

1. RC412 Cables

2. Screws and parts for rails

3. Small rails

 

Box 2

1. Vacuum valves

2. IDC cables

 

Box 3 (Detectors)

1. WI-20

3186-9

2. WI-150

3458-4

3. WI-150

3458-1

 

 

Box 4 (Detector)

1. WI-20

3485-12

*List

 

**We also have the tube for the long rails

 

  40   Sun Oct 9 21:07:02 2022 Nikolay SosninBoron Sample 3 Measurement

21:15 Changed from detectors in-beam to boron-10 sample 3 in-beam (in-beam measurement got 1000 triggers, 500 of which were dedicated). The sample was mounted identically to LiF 3. An attempt was made to replace the 20-micron dE detector with a 50-micron one, but the screwholes on the 50-micron detector did not match the 300-micron E-detector ones and therefore could not be mounted. 20-micron detector was therefore re-attached. Planning to run for 12 hours with boron than dismount.

Attachment 1: Voltage_dE4_Resize.jpg
Voltage_dE4_Resize.jpg
Attachment 2: Voltage_E4_Resize.jpg
Voltage_E4_Resize.jpg
Attachment 3: E_dE_Position_Before_Boron_Resize.jpg
E_dE_Position_Before_Boron_Resize.jpg
Attachment 4: E_dE_Position_Boron_Above_Resize.jpg
E_dE_Position_Boron_Above_Resize.jpg
Attachment 5: E_dE_Position_Boron_Back_Resize.jpg
E_dE_Position_Boron_Back_Resize.jpg
Attachment 6: E_dE_Position_Boron_Resize.jpg
E_dE_Position_Boron_Resize.jpg
Attachment 7: Boron_Sample_Rotation_Angle_Resize.jpg
Boron_Sample_Rotation_Angle_Resize.jpg
Attachment 8: Boron_Sample3_Target_View_Resize.jpg
Boron_Sample3_Target_View_Resize.jpg
Attachment 9: Boron_Measurement_Chamber_Interior2_Resize.jpg
Boron_Measurement_Chamber_Interior2_Resize.jpg
Attachment 10: Boron_Mounted_Resize.jpg
Boron_Mounted_Resize.jpg
Attachment 11: Boron_Measurement_Chamber_Interior1_Resize.jpg
Boron_Measurement_Chamber_Interior1_Resize.jpg
Attachment 12: Boron_Sample3_Back_Resize.jpg
Boron_Sample3_Back_Resize.jpg
Attachment 13: Boron_Sample3_Front_Resize.jpg
Boron_Sample3_Front_Resize.jpg
Attachment 14: Boron_Sample3_InBeam_Resize.jpg
Boron_Sample3_InBeam_Resize.jpg
  38   Sun Oct 9 20:57:54 2022 Nikolay SosninDetectors in-beam, no target

After long beam-off, changed detector mount by moving it 2 cm forward into the beam, after removing LiF 3.

Attachment 1: Det_Holder_Default_Position_Resize.jpg
Det_Holder_Default_Position_Resize.jpg
Attachment 2: Detectors_in_Beam_CloseUp_Resize.jpg
Detectors_in_Beam_CloseUp_Resize.jpg
Attachment 3: Detectors_in_Beam_Resize.jpg
Detectors_in_Beam_Resize.jpg
Attachment 4: Voltage_E_InBeam_AfterNeutrons_Resize.jpg
Voltage_E_InBeam_AfterNeutrons_Resize.jpg
Attachment 5: Voltage_E_InBeam_BeforeNeutrons_Resize.jpg
Voltage_E_InBeam_BeforeNeutrons_Resize.jpg
Attachment 6: Mounted_LiF3_Resize.jpg
Mounted_LiF3_Resize.jpg
Attachment 7: Voltage_dE_InBeam_AfterNeutrons_Resize.jpg
Voltage_dE_InBeam_AfterNeutrons_Resize.jpg
Attachment 8: Voltage_dE_InBeam_BeforeNeutrons_Resize.jpg
Voltage_dE_InBeam_BeforeNeutrons_Resize.jpg
Attachment 9: Gamma_Flash_InBeam_1_Resize.jpg
Gamma_Flash_InBeam_1_Resize.jpg
Attachment 10: Gamma_Flash_InBeam_2_Resize.jpg
Gamma_Flash_InBeam_2_Resize.jpg
Attachment 11: LiF3_Mount_Angle_View1_Resize.jpg
LiF3_Mount_Angle_View1_Resize.jpg
Attachment 12: LiF3_Mount_Angle_View2_Resize.jpg
LiF3_Mount_Angle_View2_Resize.jpg
  37   Sat Oct 8 11:57:36 2022 Nikolay SosninChange of Detector-Target Separation

Increased detector-target (LiF 3) separation by 1.5 cm. Had to replace the support strut under the detectors due to the previous one being fuly retracted even for minimal target-detector separation. This change may affect detector rotation relative to the target.

Attachment 1: Positive_Pulser_Resize.jpg
Positive_Pulser_Resize.jpg
Attachment 2: Short_Det_Holder_In_Place_Resize.jpg
Short_Det_Holder_In_Place_Resize.jpg
Attachment 3: Short_Holder_In_Chamber_Resize.jpg
Short_Holder_In_Chamber_Resize.jpg
Attachment 4: Initia_Det_Holder_Config_Resize.jpg
Initia_Det_Holder_Config_Resize.jpg
Attachment 5: Negative_Pulser1_Resize.jpg
Negative_Pulser1_Resize.jpg
Attachment 6: Negative_Pulser2_Resize.jpg
Negative_Pulser2_Resize.jpg
Attachment 7: Negative_Pulser3_Resize.jpg
Negative_Pulser3_Resize.jpg
Attachment 8: Negative_Pulser3_Resize.jpg
Negative_Pulser3_Resize.jpg
Attachment 9: Negative_Pulser4_Resize.jpg
Negative_Pulser4_Resize.jpg
Attachment 10: E_Voltage2_Resize.jpg
E_Voltage2_Resize.jpg
Attachment 11: E_Voltage3_Resize.jpg
E_Voltage3_Resize.jpg
Attachment 12: Initial_dE_LiF3_Distance_Resize.jpg
Initial_dE_LiF3_Distance_Resize.jpg
Attachment 13: Initial_Holder_Back_View_Resize.jpg
Initial_Holder_Back_View_Resize.jpg
Attachment 14: Initial_Holder_Front_View_Resize.jpg
Initial_Holder_Front_View_Resize.jpg
Attachment 15: dE_Voltage2_Resize.jpg
dE_Voltage2_Resize.jpg
Attachment 16: dE_Voltage3_Resize.jpg
dE_Voltage3_Resize.jpg
Attachment 17: Det_Holder_Stand_Replacement_to_Short_Resize.jpg
Det_Holder_Stand_Replacement_to_Short_Resize.jpg
  36   Sat Oct 8 11:56:49 2022 Nikolay SosninSilicon Strips of Concern

DEED 6 and 9 no signal throughout the campaign.

EFED 27 high oscillations in baseline throughout the campaign.

  35   Fri Oct 7 20:04:30 2022 Nikolay SosninChange of Pulser Setting

The pulser has been switched from triggering from beam trigger to running at a 10 Hz rate, and will now appear in random places in signal traces. Planned to run overnight measuring LiF3, switch to empty + detector in beam in the morning.

  34   Fri Oct 7 17:17:08 2022 Nikolay SosninChange of Pulser Delay

Still using pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 11 microsecond delay from gamma flash to pulser. 20 mV pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Changed pulser setting to run with 11 microsecond delay for approx. 2 hour, then change to an overnight run with pulser running NOT triggered from beam.

  33   Thu Oct 6 14:58:29 2022 Nikolay SosninChange of Pulser Delay

Still using pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20 mV pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Changed pulser setting to run with 5 microsecond delay for approx. 1 hour, then change to 10 microsecond delay.

  32   Thu Oct 6 11:45:39 2022 Nikolay SosninAssembly Setup Days 1 and 2

Photographs of assembly up to the first pulser test with LiF3.

Attachment 1: LiF4_Mounted_On_Trolley_Resize.jpg
LiF4_Mounted_On_Trolley_Resize.jpg
Attachment 2: Mounted_Detectors_Resize.jpg
Mounted_Detectors_Resize.jpg
Attachment 3: Rail_Clamps_Resize.jpg
Rail_Clamps_Resize.jpg
Attachment 4: Target_Holder_Mount_Resize.jpg
Target_Holder_Mount_Resize.jpg
Attachment 5: Vacuum_Side_Resize.jpg
Vacuum_Side_Resize.jpg
Attachment 6: LiF4_Final_Position_Resize.jpg
LiF4_Final_Position_Resize.jpg
Attachment 7: LiF4_In_Chamber_Resize.jpg
LiF4_In_Chamber_Resize.jpg
Attachment 8: LiF4_Mounted_2_Resize.jpg
LiF4_Mounted_2_Resize.jpg
Attachment 9: LiF4_Mounted_Resize.jpg
LiF4_Mounted_Resize.jpg
Attachment 10: Final_Readout_Connection_Both_Resize.jpg
Final_Readout_Connection_Both_Resize.jpg
Attachment 11: Full_Assembly_Resize.jpg
Full_Assembly_Resize.jpg
Attachment 12: Full_Assembly_Target_Holder_View_Resize.jpg
Full_Assembly_Target_Holder_View_Resize.jpg
Attachment 13: LiF3_Final_Position_Resize.jpg
LiF3_Final_Position_Resize.jpg
Attachment 14: LiF3_Holder_Resize.jpg
LiF3_Holder_Resize.jpg
Attachment 15: E_Box_Resize.jpg
E_Box_Resize.jpg
Attachment 16: E_Detector_Resize.jpg
E_Detector_Resize.jpg
Attachment 17: E_Mounted_Resize.jpg
E_Mounted_Resize.jpg
Attachment 18: E_Voltage_Resize.jpg
E_Voltage_Resize.jpg
Attachment 19: dE_Box_Resize.jpg
dE_Box_Resize.jpg
Attachment 20: dE_Detector_Resize.jpg
dE_Detector_Resize.jpg
Attachment 21: dE_Readout_Connection_Resize.jpg
dE_Readout_Connection_Resize.jpg
Attachment 22: dE_Voltage_Resize.jpg
dE_Voltage_Resize.jpg
Attachment 23: Detector_Holder_Mount_Resize.jpg
Detector_Holder_Mount_Resize.jpg
Attachment 24: Central_Chamber_Mounted_Rails_Resize.jpg
Central_Chamber_Mounted_Rails_Resize.jpg
Attachment 25: Chamber_Support_Resize.jpg
Chamber_Support_Resize.jpg
  31   Thu Oct 6 11:07:47 2022 Nikolay SosninChange of sample/Addition of pulser

Changed from LiF 4 to LiF 3 after running with LiF 4 overnight (run title on n_TOF DAQ was not updated to refelect the change, and still says LiF 4, but the material setting of the run states correctly that hte run is with LiF 3).

Added pulser triggered from protons. 12 microsecond delay from protons to gamma-flash + 1.75 microsecond delay from gamma flash to pulser. 20 mV pulser output into 50 ohm impedance (10 mV final output) of both polarities (using two pulsers, one NE pulser and one BNC PB5 pulser). Planning torun with 1.75 microsecond delay for approx. 1 hour, change to 5 microsecond delay.

  30   Thu Oct 6 09:34:30 2022 ClaudiaTest setup Photos and cabling

Setup 5.10.22

dE 20 um (ID 2837-33) and 494 um double sided (ID 1194-9)

46 channels (2 connectors missing)

LiF4 in beam 

dE: Big flat cables from preamp 22 and 23 into 1A and 1B

E: from preamp 24+25 go into 2A, 2B and 3A 3B

LEMO converter box: Cable 1: dE

                                   Cable 3: E n+n

                                  unlabeled cable: E p+n

E detector voltage: -133 V, leakage current -0.53 micro-Amp

dE detector voltage -22 V, leakage current -0.03 micro-Amp

For the E detector one of the edge p+n strip bond-wires is suspected broken.

Attachment 1: 20221005_174742.jpg
20221005_174742.jpg
Attachment 2: 20221005_174759.jpg
20221005_174759.jpg
Attachment 3: 20221005_184752.jpg
20221005_184752.jpg
Attachment 4: 20221005_184801.jpg
20221005_184801.jpg
Attachment 5: 20221005_174742.jpg
20221005_174742.jpg
  29   Thu Oct 6 09:28:33 2022 ClaudiaItems to be replaced for next run

Missing/broken items identified

- long rails for fixing chamber on support

- vacuum valve (ours is broken)

- at least 2 lemo - BNC converters

- short M3 screws (photo)

Attachment 1: 20221005_122654.pdf
20221005_122654.pdf
  28   Thu May 26 09:20:32 2022 Nick / ClaudiaInventory of Items at n_TOF for (n,cp) experiments

Detectors currently in the boxes:

2x MSL type W1(SS)-50, 2902-4 (53um), 2940-6 (55um)

1x MSL type W1(SS)-20 2837-33 (20um)

1x MSL type W1(DS?) 1230-10  (500 or 300 um)

1x MSL type W1(DS)-500 1194-9 (494um)

 

Three aluminium crates contain 26Al(n, alpha) kit from EAR2, and was in the barracks (building 6547) near detector lab by EAR1 entrance. A list is attached and photos can be found on Dropbox:

https://www.dropbox.com/sh/68k1xove2zr1bmj/AADKvN8wR_Ia2EwZMOXZqdMCa?dl=0

Attachment 1: rn_image_picker_lib_temp_e85b2099-7b73-4246-843d-6351800c2709.jpg
rn_image_picker_lib_temp_e85b2099-7b73-4246-843d-6351800c2709.jpg
Attachment 2: rn_image_picker_lib_temp_3ff5f819-1e0c-4278-bbbc-01038a0a0c94.jpg
rn_image_picker_lib_temp_3ff5f819-1e0c-4278-bbbc-01038a0a0c94.jpg
  27   Fri Sep 9 10:01:18 2016 SarahLeakage currents 09.09.16

EFED 0.04uA
DEED 0.05uA
PHDI 0.13uA

  26   Fri Sep 2 12:03:40 2016 SarahSPD card changed

14 bit card replaced for DEED 9-12, to prevent issue with pulser arriving before gamma flash.

  25   Fri Sep 2 12:01:57 2016 SarahLeakage currents 02.09.16

E 0.03
dE 0.05
PHDI 0.12


Check on PHDI pulser width:
205170 (first in beam run) - 1.1% FWHM (at 8275 ch)
205439 (01/09/16) - 1.0% FWHM (at 8008 ch)

Seems to be holding up OK at present.

  24   Tue Aug 23 15:34:38 2016 ClaudiaLeakage currents 23.08.16

 E = 0.03uA
dE = 0.04uA
PHDI = 0.09uA

- Monitor PHDI - increasing slowly...

  23   Wed Aug 17 15:10:05 2016 SarahLeakage currents 12.08.16

 E = 0.03uA
dE = 0.04uA
PHDI = 0.06uA

- Monitor PHDI - increasing slowly...

  22   Thu Aug 11 08:19:37 2016 SarahLeakage currents 10.8.16

 At lunchtime (12.45)

E = 0.03 uA
dE  = 0.04 uA
PHDI = 0.06 uA

  21   Tue Aug 9 15:57:52 2016 SarahLeakage currents 09.08.16

 Morning - 9am

E= 0.03uA
dE= 0.04uA
PHDI= 0.06uA

 

Afternoon - 4.30pm

E=0.03uA
dE= 0.03uA
PHDI=0.05uA
 

  20   Mon Aug 8 11:02:13 2016 SarahLeakage currents 08.08.16

 E 0.03 uA
dE 0.04 uA
PHDI 0.05 uA

 

Boron target 1 towards PHDI and Boron target 3 towards dE-E.

Mylar target gluing in electronics lab.

  19   Wed Aug 3 14:48:09 2016 SarahLeakage currents 02.08 - 03.08

 02.08:

dE = 0.03 uA

E = 0.03 uA

PHDI = 0.04 uA

 

03.08:

dE = 0.03 uA

E 0.04 uA

PHDI = 0.04 uA

  18   Wed Aug 3 09:48:31 2016 SarahEFED10 alpha calibration checks

 

EFED10: (1 bin = 2 ch)

Pulser (DAQ):
- Centroid = 5396.8(6) ch
- FWHM = 41(1) ch = 0.7%
 

Pulser (Maestro):
- Centroid = 4042 ch
- FWHM = 82 ch = 1.9%
 

148Gd (DAQ):
- Centroid = 2215(1) ch
- FWHM = 57(9) ch = 2.6%

 

148Gd (Maestro):
- Centroid = 1722 ch
- FWHM = 30 ch = 1.7%

 
  17   Tue Aug 2 08:14:26 2016 SarahLeakage currents spreadsheet (26/07- 01/08)

 Steady for dE, E. Possibly rising on PHDI- monitor closely.

Attachment 1: Leakage_currents.xlsx
  16   Sun Jul 31 15:56:32 2016 SarahDEED16 Alpha calibration checks (205169)

***note that DEED 16 was on old sampling rate for 205168- so use next run, also DEED 9-12 not plugged in***


  DEED16: (1 bin = 2 ch)

Pulser (DAQ):
- Centroid = 5347(3) ch
- FWHM = 89(7) ch = 1.7%
 

Pulser (Maestro):
- Centroid = 4279 ch
- FWHM = 166 ch = 3.9%

 

*** take the following with a pinch of salt- low stats (top of peak in DAQ = 4 counts)

148Gd (DAQ):
- Centroid = 1948 ch
- FWHM = 138 ch = 7%

 

148Gd (Maestro):
- Centroid = 1586 ch
- FWHM = 11 ch = 0.7%

  15   Sun Jul 31 15:02:57 2016 SarahDEED6 Alpha calibration checks (205168)

 DEED6: (1 bin = 2 ch)

Pulser (DAQ):
- Centroid = 5145.6(6) ch
- FWHM = 51.4(1) ch = 1%
 

Pulser (Maestro):
- Centroid = 4042 ch
- FWHM = 137 ch = 3.3%
 

148Gd (DAQ):
- Centroid = 1980(1) ch
- FWHM = 64(2) ch = 3.2%

 

148Gd (Maestro):
- Centroid = 1564 ch
- FWHM = 61 ch = 3.9%

  14   Sun Jul 31 14:32:34 2016 SarahDEED1 Alpha calibration checks (205168)

 DEED1: (rebin x2 -> 1 bin = 4 ch)

Pulser (DAQ):
- Centroid = 5000(1) ch
- FWHM = 71(5) ch = 1.4%
 

Pulser (Maestro):
- Centroid = 4008 ch
- FWHM = 148 ch = 4%
 

148Gd (DAQ):
- Centroid = 1880(1) ch
- FWHM = 89(2) ch = 4.7%

 

148Gd (Maestro):
- Centroid = 1524 ch
- FWHM = 67 ch = 4.4%

 

 

  13   Sun Jul 31 13:43:56 2016 SarahAlpha spectra

 Pulser set to 100 pps.

Shaping amp:
Gain: 1x1.0x50
Tau: 2 us
Negative polarity.


 

Attachment 1: DEED0_alpha_spec_pulser.Spe
$SPEC_ID:
No sample description was entered.
$SPEC_REM:
DET# 1
DETDESC# ERUDITE Easy-MCA-8k SN 13196238
AP# Maestro Version 7.01
$DATE_MEA:
07/27/2016 11:09:06
$MEAS_TIM:
355 355
$DATA:
0 8191
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       1
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       0
       1
       1
       0
       2
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       1
       0
       0
       1
       1
       1
       0
       0
       0
       0
       0
       0
       0
       0
       1
       1
       0
       0
       0
       1
       0
       1
       0
       0
       0
       2
       0
       0
       0
       1
       0
       0
       1
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
... 7927 more lines ...
Attachment 2: DEED5_alpha_spec_pulser.Spe
$SPEC_ID:
No sample description was entered.
$SPEC_REM:
DET# 1
DETDESC# ERUDITE Easy-MCA-8k SN 13196238
AP# Maestro Version 7.01
$DATE_MEA:
07/27/2016 10:58:44
$MEAS_TIM:
559 560
$DATA:
0 8191
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       1
       0
       2
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       1
       0
       1
       0
       0
       1
       2
       2
       1
       0
       0
       1
       0
       0
       0
       1
       0
       1
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       3
       0
       2
       0
       2
       0
       0
       0
       0
       0
       0
       2
       0
       2
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       0
       0
       0
       1
       0
       0
       0
       1
       0
       2
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
       1
       0
       0
       2
       0
       0
       1
       0
       0
       1
       0
       1
       0
       1
       2
       0
       1
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       1
       0
       0
... 7927 more lines ...
Attachment 3: DEED15_alpha_spec_pulser.Spe
$SPEC_ID:
No sample description was entered.
$SPEC_REM:
DET# 1
DETDESC# ERUDITE Easy-MCA-8k SN 13196238
AP# Maestro Version 7.01
$DATE_MEA:
07/27/2016 11:15:40
$MEAS_TIM:
274 274
$DATA:
0 8191
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       1
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       0
       0
       1
       1
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
... 7927 more lines ...
Attachment 4: EFED9_alpha_spec_pulser.Spe
$SPEC_ID:
No sample description was entered.
$SPEC_REM:
DET# 1
DETDESC# ERUDITE Easy-MCA-8k SN 13196238
AP# Maestro Version 7.01
$DATE_MEA:
07/27/2016 09:31:49
$MEAS_TIM:
452 453
$DATA:
0 8191
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       1
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       1
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       2
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
... 7926 more lines ...
Attachment 5: PHDI_alpha_spec_pulser.Spe
$SPEC_ID:
No sample description was entered.
$SPEC_REM:
DET# 1
DETDESC# ERUDITE Easy-MCA-8k SN 13196238
AP# Maestro Version 7.01
$DATE_MEA:
07/27/2016 08:34:11
$MEAS_TIM:
231 231
$DATA:
0 8191
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       0
       1
       0
       2
       4
       2
       3
       1
       7
       2
       3
       3
       1
       5
       4
       3
       5
       3
       3
       6
       3
       3
       5
       5
       3
       6
       3
       1
       3
       0
       4
       0
       3
       1
       2
       3
       4
       2
       2
       7
       1
       5
       2
       0
       4
       1
       0
       2
       3
       4
       2
       4
       1
       0
       1
       1
       4
       1
       4
       2
       2
       2
       1
       1
       2
       2
       2
       2
       1
       2
       2
       2
       2
       2
       2
       1
       0
       6
       1
       2
       1
       3
       0
       0
       0
       3
       2
       4
       1
       1
       1
       2
       2
       1
       4
       1
       1
       1
       2
       1
       0
       3
       2
       1
       0
       1
       1
       0
       2
       1
       1
       3
       3
       0
       0
       3
       2
       3
       1
       2
       1
       1
       1
       0
       0
       0
       1
       1
       0
       1
       0
       0
       0
       1
       0
       0
       1
       3
       1
       0
       2
       1
       3
       0
       1
       0
       0
       0
       0
       1
       1
       0
       1
       1
       3
       0
       1
       1
       2
       4
       1
       1
       1
       0
       0
... 7925 more lines ...
  12   Thu Jul 28 16:00:43 2016 SarahList of to-dos

Process alpha data
- Compare pulser width and alpha width to calibration spectra (shaping amp with 1us and gain 50x)
- Does photodiode data process OK or is it a problem with the oscillations?

Process LiF data
- Any pile up issues? Problems with gamma flash?

 

Online monitoring:
- Check leakage every few days, check lab temp.
- Check alpha peaks of 26Al contaminants - Gd, B.
 

  11   Wed Jul 27 13:20:53 2016 SarahGafchromic images
Attachment 1: Gafchromic_scan_photos.pdf
Gafchromic_scan_photos.pdf Gafchromic_scan_photos.pdf Gafchromic_scan_photos.pdf
Attachment 2: 20160725_180604.jpg
20160725_180604.jpg
Attachment 3: 20160726_153323.jpg
20160726_153323.jpg
Attachment 4: New_Doc_19_1_1469601914249.jpg
New_Doc_19_1_1469601914249.jpg
Attachment 5: New_Doc_19_2_1469601914138.jpg
New_Doc_19_2_1469601914138.jpg
Attachment 6: New_Doc_19_3_1469601913934.jpg
New_Doc_19_3_1469601913934.jpg
  10   Fri Oct 16 16:11:41 2015 Sarah Lonsdale09/10/15 Photos of detectors (reversed dE wiring) and upper level frame for future set up, leakage current

 Leakage before take down:
de 0.07 micro A
E 0.47 micro A

Attachment 1: 2015-10-09_09.16.16.jpg
2015-10-09_09.16.16.jpg
Attachment 2: 2015-10-09_09.16.22.jpg
2015-10-09_09.16.22.jpg
Attachment 3: 2015-10-09_09.29.23.jpg
2015-10-09_09.29.23.jpg
Attachment 4: 2015-10-09_09.29.35.jpg
2015-10-09_09.29.35.jpg
Attachment 5: 2015-10-09_09.30.02.jpg
2015-10-09_09.30.02.jpg
  9   Fri Oct 16 16:01:41 2015 Sarah Lonsdale08/10/15 Removed source and sample, leakage current check

Removed source and removed Li sample for blank frame test

Leakage
DE 0.06micro A
E 0.41 micro A

 

DAQ 
56.25 sample rate all except EBED 5,6,7

  8   Fri Oct 16 15:56:01 2015 Sarah Lonsdale07/10/15 Alpha source in, change to pulser delay

Alpha source in - containing 148Gd, 241Am, 239Pu, 244Cm (4x 1kBq)

Leakage on arrival
dE 0.08microA , 19V

E 0.48microA 132V

At leaving
dE 0.08 micro A
E 0.41 micro A

Pulser to 20ms (2015-10-07_13.58.08.jpg)


DAQ:

EBED 5,6,7 have post sample 16382
Increased further at 4pm - 16000+ post sample for 225 samples

 

 

Attachment 1: 2015-10-07_13.58.08.jpg
2015-10-07_13.58.08.jpg
Attachment 2: 2015-10-07_09.53.40.jpg
2015-10-07_09.53.40.jpg
Attachment 3: 2015-10-07_09.54.47.jpg
2015-10-07_09.54.47.jpg
Attachment 4: 2015-10-07_09.55.55.jpg
2015-10-07_09.55.55.jpg
Attachment 5: 2015-10-07_09.59.09.jpg
2015-10-07_09.59.09.jpg
Attachment 6: 2015-10-07_14.07.55.jpg
2015-10-07_14.07.55.jpg
  7   Fri Oct 16 15:41:14 2015 Sarah Lonsdale06/10/15 Changes to DAQ and pulser settings

 Pulser out of 5,6,7 EFED- extended to 32ms

Changed full scale on ADC to 0.2V,
Offset changed by factor of 10.
Zero suppression on, de -3mV thresh
E +-5mV thresh
Post sample 4096

5pm increased post sample for spd-02886 to 8192 as higher sample rate due to pick up.

Corrected EBED 4 offset.

(Again, all DAQ settings also recorded to the nToF erunbook)

Changed pulser to 13ms.

Attachment 1: 2015-10-06_delay.jpg
2015-10-06_delay.jpg
Attachment 2: 2015-10-06_trig.jpg
2015-10-06_trig.jpg
  6   Fri Oct 16 15:36:13 2015 Sarah Lonsdale06/10/15 Leakage, dE signal problem solving and external pulser trigger

 Leakage tues am
0.03 microA dE
0.52 microA E

Before leaving at 11.30am or so-
Bias dE up to 20V, leakage to 0.07microA
E has 0.51 microA

Problem solving dE signals...
SIG l6d6 a has signal of 600mV
SIG 24 has signal of 500mV
White noise is comparable, but transient ringing on l6d6 could indicate higher capacitance

Testing dE for signal with alpha source- but removed before continuing run.
dE sees particles after rotating ribbon by 180 degrees (abnormal detector)

External pulser triggering (2015-10-06_11.30.jpg )
Pulsar trigger, +2.5V external from proton pulse (10ms before beam), lasts 1ms (width).

Convert pulse input from TTL to NIM to go into delay (15ms).
Start delay in dual timer, then output to trigger pulser (TTL)

Attachment 1: 2015-10-06_10.04.06.jpg
2015-10-06_10.04.06.jpg
Attachment 2: 2015-10-06_10.35.28.jpg
2015-10-06_10.35.28.jpg
Attachment 3: 2015-10-06_10.37.10.jpg
2015-10-06_10.37.10.jpg
Attachment 4: 2015-10-06_10.37.58.jpg
2015-10-06_10.37.58.jpg
Attachment 5: 2015-10-06_11.06.23.jpg
2015-10-06_11.06.23.jpg
Attachment 6: 2015-10-06_11.30.jpg
2015-10-06_11.30.jpg
  5   Tue Oct 13 21:04:49 2015 Claudia LedererPhotos of Test Setup 5-10 October 2015

some photos in high resolution of the test setup 5-10 October 2015

Attachment 1: DSC00042.JPG
DSC00042.JPG
Attachment 2: DSC00048.JPG
DSC00048.JPG
Attachment 3: DSC00056.JPG
DSC00056.JPG
Attachment 4: DSC00065.JPG
DSC00065.JPG
  4   Mon Oct 12 12:07:24 2015 Sarah Lonsdale05/10/15 Changes to DAQ settings

 Note that detailed DAQ information available from project-ntof.cern.ch erunbook ear2.

As a rough guide: 6/7 mV per MeV

5mV thresh back side E, -5mV front E
-5mV dE
Implemented from Run 203388

From Run 203389
-7mV in Deed 8&9, EFED
+7mV in EBED

Run 203390
Thresholds back to -6mV for deed 8&9

Gamma flash ends at 70micro sec, corresponds to neutron energy of ~200keV...

  3   Mon Oct 12 12:04:51 2015 Sarah Lonsdale05/10/15 Photo of detector distances and layout

Fairly self explanatory, note that images with time-stamps before 13.08.29 were taken before fitting the o-ring on the flange and therefore lateral positions will be different to photos after 13.08.29. Individual detector heights were not changed.

Attachment 1: 2015-10-05_13.08.29.jpg
2015-10-05_13.08.29.jpg
Attachment 2: 2015-10-05_13.08.45.jpg
2015-10-05_13.08.45.jpg
Attachment 3: 2015-10-05_13.08.52.jpg
2015-10-05_13.08.52.jpg
Attachment 4: 2015-10-05_13.09.02.jpg
2015-10-05_13.09.02.jpg
Attachment 5: 2015-10-05_12.55.05.jpg
2015-10-05_12.55.05.jpg
Attachment 6: 2015-10-05_12.55.27.jpg
2015-10-05_12.55.27.jpg
Attachment 7: 2015-10-05_12.55.40.jpg
2015-10-05_12.55.40.jpg
Attachment 8: 2015-10-05_13.12.07.jpg
2015-10-05_13.12.07.jpg
  2   Mon Oct 12 11:50:52 2015 Sarah Lonsdale05/10/15 Pulser, Wiring information and DAQ initial set up

600mV in 50ohm coax with 25 hz pulser (positive signal) - see 2015-10-05_15.19.54.jpg and 2015-10-05_15.22.46.jpg



Leakage currents on detectors:

In air
10v: 0.03 micro amp det 1 leakage -dE
132v: 0.47micro amp det 2 leakage- E det

In vacuum
DE 0.04 micro amp
E 0.46 micro amp

Same size of signal at ADC hence 50 ohms coaxial.

The following channel explanations refer to cables at control area (not vault) see (
2015-10-05_15.19.54.jpg) for full wiring information.


dE det= DEED 0 to -2V full scale, Lower limit 1800mV, Threshold 0V, thresh neg, pre 1024, post 2048, 20ms window, sample rate 225 MS/s
- L6D6 A = de 4
- L6D6 B = de 5
- L6D6 C = de 6
- L6D6 D = de 7
- LaBr 3 = de 8
- 21 = de 9

E det front= EFED 0 to -2V full scale, Lower limit 1800mV, Threshold 0V, thresh neg, pre 1024, post 2048, 20ms window, sample rate 225 MS/s
- 10 = Ef 3
- 12 = Ef 4
- 13 = Ef 5
- 14 = Ef 6
- 15 = Ef 7

E det back= EBED 0 to +2V full scale, Lower limit -200mV, Threshold 0V, thresh pos, pre 1024, post 2048, 20ms window, sample rate 225 MS/s (except EBED 5,6,7 which MUST be 900MS/s due to beam pick up signal)
- 16 = Eb 3
- 18 = Eb 4
- 20 = Eb 5
- 38 = Eb 6
- 40 = Eb 7

Run number 203385 on https://project-ntof.web.cern.ch/project-ntof/eRunbookEAR2.php

Attachment 1: 2015-10-05_15.19.54.jpg
2015-10-05_15.19.54.jpg
Attachment 2: 2015-10-05_15.20.24.jpg
2015-10-05_15.20.24.jpg
Attachment 3: 2015-10-05_15.22.39.jpg
2015-10-05_15.22.39.jpg
Attachment 4: 2015-10-05_15.22.46.jpg
2015-10-05_15.22.46.jpg
  1   Mon Oct 12 11:27:02 2015 Sarah Lonsdale05/10/15 - Set up notes

 20 micron (see 2015-10-05_12.46.59.jpg for detailed information) and 500 micron detectors

Testing preamps using pulser through common wire to both sets of preamps (see 2015-10-05_13.12.01.jpg).

64 x 14mA pos signals 15V
64 x 4mA neg signals 15V (see 2015-10-05_12.02.00.jpfor example on oscilloscope)

Sample has 105 microgram Li-6 (LiF - 95% enriched) 105 micron thick (2015-10-05_12.12.15.jpis Li-6 side up, 2015-10-05_12.12.26.jpis Li-6 side down... do not mix up!)

dE uses 22, 23 on ribbon connector, E 24, 25
dE from bias supply 2, E from bias 1

de and E pos signals needed to be inverted using jumpers. de negs not used, only 16ch (see 2015-10-05_14.59.12.jpg)


de first and last (0,15) are noisy- don't use. E detector ch 0 doesn't work.
Channels used dE 4-9, E(pos) 3-7 and E(neg) 3-7 (see
2015-10-05_15.11.37.jpg and 2015-10-05_15.11.44.jpg)

Attachment 1: 2015-10-05_12.46.59.jpg
2015-10-05_12.46.59.jpg
Attachment 2: 2015-10-05_12.02.00.jpg
2015-10-05_12.02.00.jpg
Attachment 3: 2015-10-05_12.12.15.jpg
2015-10-05_12.12.15.jpg
Attachment 4: 2015-10-05_12.12.23.jpg
2015-10-05_12.12.23.jpg
Attachment 5: 2015-10-05_13.12.01.jpg
2015-10-05_13.12.01.jpg
Attachment 6: 2015-10-05_14.59.12.jpg
2015-10-05_14.59.12.jpg
Attachment 7: 2015-10-05_15.11.44.jpg
2015-10-05_15.11.44.jpg
Attachment 8: 2015-10-05_15.11.37.jpg
2015-10-05_15.11.37.jpg
ELOG V3.1.4-unknown